Search NASA⌕ Search

Engineering topics

C L Amick

Publications and source records attributed to C L Amick.

New Cryogenic Method for Combining Lunar Regolith Simulant and Frozen Volatiles to Generate Icy Lunar Simulated Regolith

There is a requirement within the lunar science and exploration communities to develop lunar simulants containing volatiles that are solids at the cryogenic temperatures found in the permanently shadowed regions (PSRs), such as those found near the Lunar South Pole. Icy regolith simulants would be used for curation training, as well as for various research activities. One of the most critical aspects of developing a regolith simulant that is more physically and chemically like icy lunar regolith is minimizing any form of modification driven by elevated temperatures. Here we document our ongoing efforts to combine materials at ultralow temperatures, designed to minimize any chemical reactions or other physical changes during the production of the icy regolith. Our goal is to document how one can create an essentially “unreacted” icy regolith that can serve as an effective “time zero” start point from which advanced curation research will proceed. This is done using commercial off-the-shelf equipment as much as possible, along with creating a custom spray plate that can be adapted to a wide variety of methods, all for the planetary simulant community. This method creates crystals of various volatiles such as water, methanol, along with CO 2 ice and these components are combined with lunar regolith that is at -196°C temperature to avoid chemical reactions, and/or phase changes thus creating a more chemically relevant icy lunar regolith. The rules of chemistry stay the same regardless of location whether it’s in the lab, or directly on the lunar surface, and therefore we aim for creating a more authentic icy lunar simulant in the laboratory by operating at ultralow temperatures. It is also envisioned that this method will lead to advanced materials testing in the future. In addition, this method is directly applicable to prior missions such as LCROSS.

Cryogenic Lunar Simulant and Icy Volatile Producti↗

New Cryogenic Method for Combining Lunar Regolith Simulant and Frozen Volatiles to Generate Icy Lunar Simulated Regolith

There is a requirement within the lunar science and exploration communities to develop lunar simulants containing volatiles that are solids at the cryogenic temperatures found in the permanently shadowed regions (PSRs), such as those found near the Lunar South Pole. Icy regolith simulants would be used for curation training, as well as for various research activities. One of the most critical aspects of developing a regolith simulant that is more physically and chemically like icy lunar regolith is minimizing any form of modification driven by elevated temperatures. Here we document our ongoing efforts to combine materials at ultralow temperatures, designed to minimize any chemical reactions or other physical changes during the production of the icy regolith. Our goal is to document how one can create an essentially “unreacted” icy regolith that can serve as an effective “time zero” start point from which advanced curation research will proceed. This is done using commercial off-the-shelf equipment as much as possible, along with creating a custom spray plate that can be adapted to a wide variety of methods, all for the planetary simulant community. This method creates crystals of various volatiles such as water, methanol, along with CO 2 ice and these components are combined with lunar regolith that is at -196°C temperature to avoid chemical reactions, and/or phase changes thus creating a more chemically relevant icy lunar regolith. The rules of chemistry stay the same regardless of location whether it’s in the lab, or directly on the lunar surface, and therefore we aim for creating a more authentic icy lunar simulant in the laboratory by operating at ultralow temperatures. It is also envisioned that this method will lead to advanced materials testing in the future. In addition, this method is directly applicable to prior missions such as LCROSS.

Cryogenic Lunar Simulant and Icy Volatile Producti↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements.

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗