Search NASA⌕ Search

Engineering topics

Cabrera, B

Publications and source records attributed to Cabrera, B.

22 records · Page 2

Results from a Low-Energy Analysis of the CDMS II Germanium Data

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below {approx}10 GeV/c{sup 2}. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c{sup 2} and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A low-threshold analysis of CDMS shallow-site data

Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four {approx}224 g germanium and two {approx}105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of {approx}1 keV and {approx}2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c{sup 2}. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments data as WIMP signals, and exclude new parameter space for WIMP masses between 3 GeV/c{sup 2} and 4 GeV/c{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contact-Free Germanium Ionization and Phonon Detectors

A new method to study the origin of the dead-layer in ionization-phonon detectors was developed wherein the ionization is measured via a 25 micron gap between the collection electrodes and germanium absorber. Phonon signals are measured with small tungsten thermometers (Tc{approx}90 mK) varnished to the Ge substrates. The Ge samples were studied using collimated {sup 241}Am sources. With this geometry, different contributions to the 'dead-layer' effect can be studied independently: Carrier back diffusion, trapping on surface states, Schottky barrier lowering, etc.

36 MATERIALS SCIENCE↗

Results from the Final Exposure of the CDMS II Experiment

We report results from a blind analysis of the final data taken with the Cryogenic Dark Matter Search experiment (CDMS II) at the Soudan Underground Laboratory, Minnesota, USA. A total raw exposure of 612 kg-days was analyzed for this work. We observed two events in the signal region; based on our background estimate, the probability of observing two or more background events is 23%. These data set an upper limit on the Weakly Interacting Massive Particle (WIMP)-nucleon elastic-scattering spin-independent cross-section of 7.0 x 10{sup -44} cm{sup 2} for a WIMP of mass 70 GeV/c{sup 2} at the 90% confidence level. Combining this result with all previous CDMS II data gives an upper limit on the WIMP-nucleon spin-independent cross-section of 3.8 x 10{sup -44} cm{sup 2} for a WIMP of mass 70 GeV/c{sup 2}. We also exclude new parameter space in recently proposed inelastic dark matter models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗