Operating Experience Review of Tritium-in-Water Monitors

Monitoring tritium facility and fusion experiment effluent streams is an environmental safety requirement. This paper presents data on the operating experience of a solid scintillant monitor for tritium in effluent water. Operating experiences were used to calculate an average monitor failure rate of 4E-05/hour for failure to function. Maintenance experiences were examined to find the active repair time for this type of monitor, which varied from 22 minutes for filter replacement to 11 days of downtime while waiting for spare parts to arrive on site. These data support planning for monitor use; the number of monitors needed, allocating technician time for maintenance, inventories of spare parts, and other issues.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Component Failure Rate Data Sources for Probabilistic Safety and Reliability

Probabilistic safety methods are being used in several industries, including chemical, manufacturing, and energy. When performing reliability studies or using probabilistic safety approaches, a basic need arises for input data on failure rates of the mechanical, electrical, instrumentation and control, and other components that comprise the engineering systems in the facility. Some companies have many types of data stored and can retrieve these in-house data for such uses. Other companies hire consultants to perform safety assessments; the consulting firms often use their own data bases. For those analysts who do not have either of those options available, this paper presents some data sources that are retrievable from the literature. These data sources have been evaluated with a basic rating of usefulness for analysis work, and each has a description of what data can be found in the citation that can be used to support assessments in industry. The accessibility of data documents via the internet is also described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vacuum Bellows, Vacuum Piping, Cryogenic Break, and Copper Joint Failure Rate Estimates for ITER Design Use

The ITER international project design teams are working to produce an engineering design in preparation for construction of the International Thermonuclear Experimental Reactor (ITER) tokamak. During the course of this work, questions have arisen in regard to safety barriers and equipment reliability as important facets of system design. The vacuum system designers have asked several questions about the reliability of vacuum bellows and vacuum piping. The vessel design team has asked about the reliability of electrical breaks and copper-copper joints used in cryogenic piping. Research into operating experiences of similar equipment has been performed to determine representative failure rates for these components. The following chapters give the research results and the findings for vacuum system bellows, power plant stainless steel piping (amended to represent vacuum system piping), cryogenic system electrical insulating breaks, and copper joints.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operating Experience Review of the INL HTE Gas Monitoring System

This paper describes the operations of several types of gas monitors in use at the Idaho National Laboratory (INL) High Temperature Electrolysis Experiment (HTE) laboratory. The gases monitored at hydrogen, carbon monoxide, carbon dioxide, and oxygen. The operating time, calibration, and unwanted alarms are described. The calibration session time durations are described. Some simple statistics are given for the reliability of these monitors and the results are compared to operating experiences of other types of monitors.

08 HYDROGEN↗