Search NASA⌕ Search

Engineering topics

Caldwell, T. S.

Publications and source records attributed to Caldwell, T. S..

Measurement of the electric potential and the magnetic field in the shifted analysing plane of the KATRIN experiment

The projected sensitivity of the effective electron neutrino-mass measurement with the KATRIN experiment is below 0.3 eV (90 % CL) after 5 years of data acquisition. The sensitivity is affected by the increased rate of the background electrons from KATRIN’s main spectrometer. A special shifted-analysing-plane (SAP) configuration was developed to reduce this background by a factor of two. The complex layout of electromagnetic fields in the SAP configuration requires a robust method of estimating these fields. We present in this paper a dedicated calibration measurement of the fields using conversion electrons of gaseous 83m Kr, which enables the neutrino-mass measurements in the SAP configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assay-based background projection for the Majorana Demonstrator using Monte Carlo uncertainty propagation

The background index (BI) is an important quantity to project and calculate the half-life sensitivity of neutrinoless double-𝛽 decay (0⁢𝜈⁢𝛽⁢𝛽) experiments. An analysis framework is presented to calculate the BI using the specific activities, masses, and simulated efficiencies of an experiments components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a BI distribution from the specific activity, mass, and efficiency distributions. This method is applied to the M AJORANA D EMONSTRATOR , which deployed arrays of high-purity Ge detectors enriched in 76 Ge to search for 0⁢𝜈⁢𝛽⁢𝛽. The original assay-based projection is requantified in the new framework, using the as-built geometry of the Demonstrator and additional assay information. While 47% higher than the original projection, the resulting BI of [8.95±0.36]×10 −4 cts/(keVkgyr) from the 232 Th and 238 U decay chains does not account for the higher-than-expected BI observed by the D EMONSTRATOR . Finally, this method enables us to demonstrate the statistical incompatibility between the D EMONSTRATOR 's observed background and the assay results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for charge non-conservation and Pauli exclusion principle violation with the M AJORANA D EMONSTRATOR

Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the M AJORANA D EMONSTRATOR experiment. Using a 37.5 kg yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the e → v e $\overline{v_e}$ v e decay channel by more than an order of magnitude. Here, we also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exotic Dark Matter Search with the Majorana Demonstrator

With excellent energy resolution and ultralow-level radiogenic backgrounds, the high-purity germanium detectors in the enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos ν s → ν a . We report new limits on fermionic dark matter absorption ( χ + A → ν + A ) and sub-GeV DM-nucleus 3 → 2 scattering ( χ + χ + A → ϕ + A ), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1–100)-keV low-energy region of a 37.5-kg y exposure collected by the between May 2016 and November 2019 using a set of Ge 76 -enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Constraints on the Decay of 180⁢𝑚 Ta

180m Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known β and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the Majorana Demonstrator, an experimental search for the neutrinoless double-beta decay of 76 Ge using an array of high-purity germanium detectors, to search for the decay of 180m Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background Majorana Demonstrator detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the 180m Ta half-life on the different decay channels. With new limits up to 1.5 × 10 19 years, we improved existing limits by one to two orders of magnitude. Furthermore, this result is the most sensitive search for a single β and electron capture decay ever achieved.

150 ≤ A ≤ 189↗

Search for keV-scale sterile neutrinos with the first KATRIN data

In this work we present a keV-scale sterile-neutrino search with a low-tritium-activity data set of the KATRIN experiment, acquired in a commissioning run in 2018. KATRIN performs a spectroscopic measurement of the tritium β-decay spectrum with the main goal of directly determining the effective electron anti-neutrino mass. During this commissioning phase a lower tritium activity facilitated the measurement of a wider part of the tritium spectrum and thus the search for sterile neutrinos with a mass of up to 1.6 keV. We do not find a signal and set an exclusion limit on the sterile-to-active mixing amplitude of $\text {sin}^{2}\: \theta<5\times 10^{-4}\: (95\%\: $C.L) at a mass of 0.3 keV. This result improves current laboratory-based bounds in the sterile-neutrino mass range between 0.1 and 1.0 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Lorentz-invariance violation with the first KATRIN data

Some extensions of the Standard Model of particle physics allow for Lorentz invariance and charge-parity-time invariance violations. In the neutrino sector strong constraints have been set by neutrino-oscillation and time-of-flight experiments. However, some Lorentz-invariance-violating parameters are not accessible via these probes. In this work, we focus on the parameters (a$^{(3)}_{of}$)00, (a$^{(3)}_{of}$)10, and (a$^{(3)}_{of}$)11 which would manifest themselves in a nonisotropic β-decaying source as a sidereal oscillation and an overall shift of the spectral endpoint. Based on the data of the first scientific run of the KATRIN experiment, we set the first 90% confidence-level limit on (a$^{(3)}_{of}$)11| of < 0.9 × 10 –6 GeV to 3.7 × 10 –6 GeV, depending on the phase. Furthermore, we derive new constraints on (a$^{(3)}_{of}$)00 and (a$^{(3)}_{of}$)10.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interpretable boosted-decision-tree analysis for the Majorana Demonstrator

The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗