Search NASA⌕ Search

Engineering topics

Call, Geran R.

Publications and source records attributed to Call, Geran R..

Performance Test of Mini LVDT - ELVIS

The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laboratory Testing of the Temperature Sensor Qualification Device

The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗