Search NASA⌕ Search

Engineering topics

Campbell, Emily L.

Publications and source records attributed to Campbell, Emily L..

25 records · Page 2

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange of Selected Group II Metals and Lead by Crystalline Silicotitanate and Competition for Cs Exchange Sites

A series of batch contact tests were conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto crystalline silicotitanate (CST) in support of an expedited Cs removal and pretreatment system at the Hanford site. Binary Na/M 2+ and ternary Na/Cs/M 2+ isotherms were generated to understand selectivity, capacity, and competitive impact of each analyte on Cs uptake from a simple 1 M NaOH/4.6 M NaNO 3 simulant. Analyte loading from a 0.1 M NaOH/5.5 M NaNO 3 simulant was assessed to determine the effect of hydroxide concentration on binary Na/M 2+ isotherms. Finally, results from binary and ternary isotherms indicated that group II metals, and Pb do not impact CST performance toward CST at concentrations expected in Hanford tank waste supernate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Spent Purolite A530E Resin with Implications for Long-Term Radioactive Contaminant Removal

Direct removal of pertechnetate anion (TcO4-) from the subsurface contaminated plumes at legacy nuclear weapons production sites, is effective remediation strategy to prevent their spread to adjacent aquifers but is also challenging because TcO4- is a trace component of the contaminated groundwater typically containing large access of other anionic constituents, such nitrate, sulfate, chloride and others. It can be achieved through ion exchange treatment using Purolite A530E resin which to date however has only been evaluated under laboratory conditions and many questions regarding its long-term operational performance remain. To address this need, here we report comprehensive characterization of the spent Purolite A530E resin which processed over 5.38x109 L of contaminated groundwater and successfully removed about 3.78 Ci of Tc-99 during four years of operation at the 200 West Pump & Treat facility at the US DOE Hanford site. This Tc-99 loading constitutes however only about 0.034% of the theoretical capacity of the resin which retained significant amounts of sulfate. Among other radioactive contaminants, small quantities of U-238, Co-60, and I-129 were retained by the resin. The total loading of iodine (combined 1-127 and I-129) on the spent resin exceeded that of Tc-99. To elucidate the mechanism of iodine retention, ion exchange behavior of iodide and iodate was investigated. Purolite A530E resin exhibited highly efficient uptake of iodide and only moderate affinity for iodate in accord with their Gibbs energy of hydration. Sorption isotherms for both anions obeyed Freundlich model.

Levitskaia, Tatiana G.↗

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystalline Silicotitanate Batch Contact Testing with Ba, Ca, Pb, and Sr

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank Side Cesium Removal system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. Processing of actual tank waste supernate showed effectively complete uptake of Sr and Ba by CST and significant uptake of Ca. Further, Campbell et al. (2019) analyzed CST post-column testing and found significant (>1E-2 mmoles/g) uptake of Ca and Pb along with some Ba, Cd, Fe, Sr, and U. This led to concern that selected metals, particularly the +2 cations, Ca, Sr, Ba, and Pb may be consuming Cs exchange sites and possibly reducing CST capacity for Cs. Exchange of +2 cations was assumed to be associated with the M(OH) + species for the metal (M) ion in the caustic solution. A series of batch contact testing was conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto CST. The Cs exchange behavior was also tested as a benchmark for direct comparisons. The CST was provided in the sodium form by Honeywell UOP, as IONSIV TM R9140-B, Lot 2002009604, 18 x 50 mesh. A <30-mesh aliquot was collected to match the sieve fraction expected for use in upcoming small column test configurations. Kinetic exchange rate and isotherms were measured at metal concentrations benchmarked from the AP-107 tank waste feed composition and as limited by the metal solubility in the alkaline solution. Two simplified matrices were tested: 1) 1.0 M NaOH/4.6 M NaNO 3 and 2) 0.1 M NaOH/5.5 M NaNO 3 ; these matrices represented the expected 5.6 M Na concentration of process feed and served to address the hydroxide concentration effect on exchange behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Elemental characterization of crystalline silicotitanate following Hanford tank waste processing

To expedite vitrification of low activity waste at the Hanford Site, a Tank-Side Cesium Removal system is being evaluated. This method utilizes an inorganic ion exchange (IX) media, crystalline silicotitanate (CST), to remove 99.9% of the 137Cs from tank waste supernate. Laboratory scale testing of the ion exchange process has been conducted by Pacific Northwest National Laboratory to evaluate Cs removal with CST in supernates collected from Hanford tanks 241-AP-107 and 241-AW-102 under prototypic plant operating conditions. In an effort to understand the selectivity and partitioning of other analytes toward CST, specifically Resource Conservation and Recovery Act (RCRA) hazardous metals, selected +2 cations, and transuranic elements, a method for the complete dissolution of CST and Cs removal from the digestate was applied to the spent CST post-processing Hanford tank waste. The CST was shown to adsorb a relevant fraction of Ca, Cd, Pb, Sr, and potentially Fe by IX and/or other mechanisms. The spent CST also adsorbed actinides, including U, Pu, Np, and Am. This work discusses digestion of CST and removal of Cs from the digestate allowing effective analysis and provides insight as to what analytes may be competing for IX sites on the CST media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗