Toward an Optically Pumped Magnetometer Magnetoencephalography System with Full Head Coverage
An overview of recent development of our MEG system. Most of the included data/figures are already published in the open literature.
Engineering topics
Publications and source records attributed to Campbell, Kaleb.
An overview of recent development of our MEG system. Most of the included data/figures are already published in the open literature.
We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Here, we demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87 Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/ √ Hz with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth’s field.
We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spatially separated magnetometers. Operation of the gradiometer in multiple field orientations is discussed. The noise floor is measured as low as 25$\frac{fT}{\sqrt{Hz-cm}}$ in a room without magnetic shielding.