Search NASA⌕ Search

Engineering topics

Campbell, M.

Publications and source records attributed to Campbell, M..

At least 19 records

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and construction of the Chips water Cherenkov neutrino detector

Chips (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the Chips detector along with details of the implementation and deployment of the prototype. While issues during and after the deployment of the detector prevented data taking, a number of key concepts and designs were successfully demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e Run I Sensitivity Projections for the Neutrinoless Conversion Search in Aluminum

The Mu2e experiment at Fermilab will search for the neutrinoless conversion in the field of an aluminum nucleus. The Mu2e data-taking plan assumes two running periods, Run I and Run II, separated by an approximately two-year-long shutdown. This paper presents an estimate of the expected Mu2e Run I search sensitivity and includes a detailed discussion of the background sources, uncertainties of their prediction, analysis procedures, and the optimization of the experimental sensitivity. The expected Run I discovery sensitivity is , with a total expected background of events. In the absence of a signal, the expected upper limit is at 90% CL. This represents a three order of magnitude improvement over the current experimental limit of at 90% CL set by the SINDRUM II experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Three-Dimensional Combustion of Heterogeneous Propellants

A numerical framework is described which permits the calculation of the 3-D combustion field supported by a heterogeneous propellant, allowing for complete coupling between the condensed phase physics, the gas-phase physics, and the unsteady, uneven, regressing surface. A random packing algorithm is used to construct models of ammonium-perchlorate in hydroxyl-terminated-polybutadiene propellants which mimic experimental propellants designed by R. Miller, and these are numerically burnt. Mean burning rates are compared with experimental data for four packs, over a pressure range of 7-200atm.

Massa, L.↗

Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

Parabolic Flight↗

Implementation of Precision Verification Solvents on the External Tank

This paper presents the Implementation of Precision Verification Solvents on the External Tank. The topics include: 1) Background; 2) Solvent Usages; 3) TCE (Trichloroethylene) Reduction; 4) Solvent Replacement Studies; 5) Implementation; 6) Problems Occuring During Implementation; and 7) Future Work. This paper is presented in viewgraph form.

Campbell, M.↗

Far-infrared and radio observations of DR 6, DR 7, and DR 22

Far-infrared maps are presented for three young H II regions in the Cygnus X region. DR 6 and 7 were mapped in the wavelength band from 40 to 250 microns at 1 arcmin resolution, while DR 22 was mapped in the same band and also at 100-250 microns, providing dust temperature and optical depth information. New VLA maps of these sources are also presented. It is concluded that DR 6 and 7 are powered by clusters of late O or early B type stars, with ages 100,000 yr or less, while DR 22 appears to be produced by a single O6 ZAMS star. Existing (C-12)O maps suggest that the formation of these objects occurred near the edges of molecular clouds.

Odenwald, S.↗

SEM visualization of glycosylated surface molecules using lectin-coated microspheres

There are several techniques currently used to localize glycosylated surface molecules by scanning electron microscopy (Grinnell, 1980; Molday, 1976; Linthicum and Sell, 1975; Nicolson, 1974; Lo Buglio, et al, 1972). A simple and rapid method, using a modification of Grinnell's technique is reported here. Essentially, microspheres coated with Concavalin A are used to bind to glycosylated regions of the palatal shelf epithelium and are visualized in the scanning electron microscope (SEM).

Non-NASA Center↗

Acceleration of fusion in mouse palates by in vitro exposure to excess G

Palatal shelves from 13- and 14-day mouse embryos were excised and cultured in contiguous pairs. Experimental cultures were exposed to 2.6 G in a culture centrifuge; controls were in the same incubator. After 24 hours, palates were prepared for light or electron microscopy. Scoring of paraffin sections according to the stage of fusion seen in the medial epithelial edges (MEE) showed that palates exposed to excess G were in more advanced stages of fusion than were controls. Ultrastructurally, control MEE had tightly apposed cell membranes and numerous desmosomes; in centrifuged MEE, desmosomes had been removed and there was much intercellular space. Nuclear membranes were intact in control MEE, but showed marked deterioration in MEE of centrifuged palates. Few lysosomes and no necrosis were seen in control MEE; centrifuged MEE had numerous lysosomes as well as necrotic cells. Basal lamina were intact in controls, but interrupted in centrifuged palates. The results confirm the hypothesis that gravitational increases speed up the differentiative process.

Duke, J.↗

Change in the high-energy radiation from the Crab

On 1973 July 23, the Cornell gamma-ray telescope had a second exposure to the Crab Nebula and pulsar via balloon flight from Palestine, Texas. On the previous flight, 1971 October 6, the signal from the pulsar had been unmistakably clear, especially at the highest energies (above 800 MeV), and an unpulsed component of similar average power had also been discernible. On the second flight, despite higher altitude, longer exposure, and improved electronics, the pulsed signal was barely detectable and the dc component not observable at all. The drop in intensity seems to increase with energy, being only a factor of 2 at 200 MeV but an order of magnitude at 1 GeV. There is some indication (not compelling) that the gamma-ray flux may have changed even within the 6-hour exposure. The first flight may have viewed the Crab in a state of enhanced high-energy emission correlated with the glitches that occurred on 1971 August 1 and October 25.

Greisen, K.↗

Upper limits of hard gamma-ray emission from six X-ray sources

The Cornell 100-inch gamma-ray telescope has been used to set upper limits for the gamma-ray flux above 400 MeV from the X-ray sources Cyg X-1, Cyg X-2, Cyg X-3, Cas A, Cas B, and Per X-1. An upper limit for the diffuse flux of the galactic disk was set which is consistent with OSO-3 and SAS-2 data. A new measurement of the atmospheric gamma-ray generation rate is presented.

Campbell, M.↗

Pulsed high-energy gamma rays from the Crab Nebula.

Review of recorded data on the pulsed radiation detected by the Cornell 100-inch gas-Cerenkov gamma-ray telescope within 1 degree of the Crab Nebula in direction, at hundreds of MeV up to more than 1 GeV, coincident in time with optical pulses from NP 0532. A main pulse and a secondary pulse are shown to contain about an equal number of events and display evidence of being narrower than at lower energies. There is weak evidence for further pulse structure in the interval between these two peaks, and also for an unmodulated gamma-ray component about equal to the time-averaged pulsed flux.

Mcbreen, B.↗

Some physical properties of Apollo 12 lunar samples

The size distribution of the lunar fines is measured, and small but significant differences are found between the Apollo 11 and 12 samples as well as among the Apollo 12 core samples. The observed differences in grain size distribtuion in the core samples are related to surface transportation processes, and the importance of a sedimentation process versus meteoritic impact gardening of the mare grounds is discussed. The optical and the radio frequency electrical properties are measured and are also found to differ only slightly from Apollo 11 results.

Gold, T.↗

Optical and high frequency electrical properties of the lunar sample

Reflectivity and polarization laws for the powder sample and its spectrum are close to the mean for the lunar maria. Solid samples show a marked absorption feature at 1 micron. The low albedo appears to be due to a surface coating on dust grains rather than volume absorption. The high frequency electrical properties resemble those of a fine powder made from typical dense terrestrial rocks, and are consistent with previous ground-based radar estimates. The differential mass spectrum is almost constant from 100 micron particles down to 0.1 micron; most particles are smaller than 0.3 micron. Their shapes disclose a variety of generation processes.

Gold, T.↗