Search NASA⌕ Search

Engineering topics

Campbell, Medbh

Publications and source records attributed to Campbell, Medbh.

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Neutrino Oscillations in the NOvA and CHIPS Detectors.

NOvA is a long baseline neutrino experiment which uses muon neutrinos produced by the NuMI beam at the Fermi National Accelerator Laboratory to measure muon neutrino disappearance and electron neutrino appearance, among other analyses. The Far/Near Extrapolation analysis framework (FNEX) was used to measure muon neutrino disappearance using the events observed by NOvA while the NuMI beam was in Forward Horn Current configuration (i.e. this analysis uses neutrino data, not antineutrino data). The values of the parameters measured in this analysis are sin 2 θ 23 - 0.499$^{+0.098}_{-0.069}$ and Δm$^2_{32}$ - 2.454$^{+0.108}_{0.119}$ × 10 -3 eV, which is consistent with the results of NOvA’s main muon neutrino disappearance analysis using the experiment’s usual framework, known as CAF. The CHIPS detector is a water Cherenkov detector currently in construction. It will also use the NuMI beam to perform muon neutrino disappearance and electron neutrino appearance analyses. The necessary water clarity for a detector with a diameter of 25 m and a height of 6 m is discussed, as well as the results of testing water filtration systems. The filtration that will be used for the detector is a 10 µm carbon block filter and a 0.5 µm filter in series, with no reverse osmosis or ultraviolet sterilisation being used. This provides an attenuation length of 16.63 ± 0.25 m for light of 532 nm wavelength (green), so light with a wavelength of 405 nm (violet) would have an attenuation length of 133±2 m. The greatest possible distance between a PMT and any point in the detector’s volume is approximately 26 m, so 133 m is sufficient for the detector to measure Cherenkov light produced anywhere in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗