Search NASA⌕ Search

Engineering topics

Camsonne, Alexandre

Publications and source records attributed to Camsonne, Alexandre.

At least 19 records

Quantum Enhanced Tracker

We report the study and development of a novel new charged particle detector, a "Quantum Enhanced Tracker" for 3D imaging of charged particle tracks. The proposed detector relies on, and benefits from, the extremely high sensitivity of atoms, prepared in a specific quantum superposition, to external perturbations. Atoms are prepared in a so-called "dark superposition" state, a passing charged particle will disturb this quantum state, allowing atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct imaging of the particle trajectory with high resolution. This method has similarities with Cherenkov detectors where a charged particle produces light along its track, but with the major advantages of enhanced sensitivity due to the low energy required to perturb the engineered quantum state, the ability to amplify the signal using a drive laser passing through the medium, and the ability to provide a 3D track.

Zhang, Shukui↗

Measurement of the Generalized Spin Polarizabilities of the Neutron in the Low-Q{sup 2} Region

Understanding the nucleon spin structure in the regime where the strong interaction becomes truly strong poses a challenge to both experiment and theory. At energy scales below the nucleon mass of about 1 GeV, the intense interaction among the quarks and gluons inside the nucleon makes them highly correlated. Their coherent behaviour causes the emergence of effective degrees of freedom, requiring the application of non-perturbative techniques such as chiral effective field theory1. Here we present measurements of the neutron’s generalized spin polarizabilities that quantify the neutron’s spin precession under electromagnetic fields at very low energy-momentum transfer squared down to 0.035 GeV2. In this regime, chiral effective field theory calculations2–4 are expected to be applicable. Our data, however, show a strong discrepancy with these predictions, presenting a challenge to the current description of the neutron’s spin properties.

Sulkosky, Vincent↗

The low Q 2 chicane and Compton polarimeter at JLEIC

The JLAB EIC (JLEIC) design includes a chicane after the interaction point to detect electron associated with production of quasi-real photon at the interaction. This chicane layout can also be used for Compton polarimetry to measure the electron beam polarization. This proceeding will present the layout of the low Q^ 2 chicane and the implementation and current R&D of a Compton polarimeter which would be located in the middle of this chicane.

Camsonne, Alexandre↗

Double Deeply Virtual Compton Scattering Opportunities At Jefferson Laboratory

Jefferson Laboratory with the current 12 GeV upgrade and a major program focused on the Generalized Parton Distributions has the opportunity to explore the Doubly Virtual Compton Scattering (DDVCS) process which would allow to probe GPDs surface for skewness di erent from the generalized bjorken variable. Such an experiment requires high luminosity because of a cross section about 100 times smaller than regular Deeply Virtual Compton Scattering. Two letter of intent were submitted to the PAC to carry out this kind of measurement. One in a modified CLAS12 setup in Hall B with a luminosity of 10^37 cm^-2.s^?1. and another one using the Solenoidal Large Intensity Device (SoLID) is a solenoidal detector equipped with Gas Elec- tron Multiplier trackers, calorimetry and Cerenkov detectors design to run with luminosity as high as a couple of 10^38 cm^-2.s^?1.

Camsonne, Alexandre↗

A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab

Here, a high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532 nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064 nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO 3 crystal. The maximum achieved green power at 5 W infrared pump power is 1.74 W with a total conversion efficiency of 34.8%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7 kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0% precision in polarization measurements of an electron beam with energy and current of 1.0 GeV and 50 μA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The low Q$^2$ chicane and Compton polarimeter at the JLab EIC

The JLAB EIC (JLEIC) design includes a chicane after the interaction point to detect electron associated with production of quasi-real photon at the interaction. This chicane layout can also be used for Compton polarimetry to measure the electron beam polarization. This proceeding will present the layout of the low Q^2 chicane and the implementation and current R&D; of a Compton polarimeter which would be located in the middle of this chicane.

Camsonne, Alexandre↗

Beam position reconstruction for the g2p experiment in Hall A at Jefferson Lab

Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. We found that before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve the required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. Finally, the calculated beam position will be used in the data analysis to accurately determine the kinematics for each event.

43 PARTICLE ACCELERATORS↗

Precision Measurement of the Neutron Twist-3 Matrix Element dn2: Probing Color Forces

Double-spin asymmetries and absolute cross sections were measured at large Bjorken x (0.25 lte x lte 0.90), in both the deep-inelastic and resonance regions, by scattering longitudinally polarized electrons at beam energies of 4.7 and 5.9 GeV from a transversely and longitudinally polarized 3He target. In this dedicated experiment, the spin structure function g2 on 3He was determined with precision at large x, and the neutron twist-three matrix element dn2 was measured at ?Q2? of 3.21 and 4.32 GeV2/c2, with an absolute precision of about 10?5. Our results are found to be in agreement with lattice QCD calculations and resolve the disagreement found with previous data at ?Q2?= 5 GeV2/c2. Combining dn2 and a newly extracted twist-four matrix element, fn2, the average neutron color electric and magnetic forces were extracted and found to be of opposite sign and about 60 MeV/fm in magnitude.

Posik, Matthew↗

Probing the Repulsive Core of the Nucleon-Nucleon Interaction via the 4 He(e,e`pN) Triple-Coincidence Reaction

We studied simultaneously the 4 He(e,e'p), 4 He(e,e'pp), and 4 He(e,e'pn) reactions at Q 2 =2 [GeV/c] 2 and x B >1, for a (e,e'p) missing-momentum range of 400 to 830 MeV/c. The knocked-out proton was detected in coincidence with a proton or neutron recoiling almost back to back to the missing momentum, leaving the residual A=2 system at low excitation energy. These data were used to identify two-nucleon short-range correlated pairs and to deduce their isospin structure as a function of missing momentum in a region where the nucleon-nucleon force is expected to change from predominantly tensor to repulsive. Neutron-proton pairs dominate the high-momentum tail of the nucleon momentum distributions, but their abundance is reduced as the nucleon momentum increases beyond ~500 MeV/c. The extracted fraction of proton-proton pairs is small and almost independent of the missing momentum in the range we studied. Our data are compared with ab-initio calculations of two-nucleon momentum distributions in 4 He.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PROGRESS ON THE INTERACTION REGION DESIGN AND DETECTOR INTEGRATION AT JLAB'S MEIC

One of the unique features of JLab's Medium-energy Electron-Ion Collider (MEIC) is a full-acceptance detector with a dedicated, small-angle, high-resolution detection system, capable of covering a wide range of momenta (and charge-to-mass ratios) with respect to the original ion beam to enable access to new physics. We present an interaction region design developed with close integration of the detection and beam dynamical aspects. The dynamical aspect of the design rests on a symmetry-based concept for compensation of non-linear effects. The optics and geometry have been optimized to accommodate the detection requirements and to ensure the interaction region's modularity for ease of integration into the collider ring lattices. As a result, the design offers an excellent detector performance combined with the necessary provisions for non-linear dynamical optimization.

Morozov, Vasiliy↗

JLab Measurement of the 4 He Charge Form Factor at Large Momentum Transfers

The charge form factor of 4 He has been extracted in the range 29 fm -2 <= Q 2 <= 77 fm -2 from elastic electron scattering, detecting 4 He nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility of Jefferson Lab. The results are in qualitative agreement with realistic meson-nucleon theoretical calculations. The data have uncovered a second diffraction minimum, which was predicted in the Q 2 range of this experiment, and rule out conclusively long-standing predictions of dimensional scaling of high-energy amplitudes using quark counting.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of modeled and measured performance of a GSO crystal as gamma detector

We have modeled, tested, and installed a large, cerium-activated Gd{sub 2}SiO{sub 5} crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.

Geant4 Gamma detection↗

Jefferson Laboratory Hall A SuperBigBite Spectrometer Data Acquisition System

The SuperBigBite detector is a large acceptance spectrometer which is being built for Hall A at Jefferson Laboratory and planned for completion in 2017. Several experiments are approved for this detector ranging from form factors to nucleon structure. The detector consists mainly of a large dipole magnet and several plane of Gas Electron Multiplier trackers associated with calorimeters. In order to reduce the cost of the project the electronics used will be a mix of older Fastbus and newly developed electronics. I will present the layout of the system and how we plan to handle the high background rates seen by the different detectors for the different experiments.

Camsonne, Alexandre↗