Search NASA⌕ Search

Engineering topics

Canavan, Ed

Publications and source records attributed to Canavan, Ed.

Development of a Flight-Worthy 10 to 4 K Continuous Adiabatic Demagnetization Refrigerator

The cryogenics and fluids branch at NASA's Goddard Space Flight Center is currently developing a high-efficiency, vibration-free, flight-worthy Continuous Adiabatic Demagnetization Refrigerator (CADR) that consist of two modular units: one that lifts ~6 microW at 50 mK while rejecting its heat to a 4 K thermal sink, and another unit that provides a constant 4 K cooling stage while rejecting its heat to a thermal sink at 10 K. The two units are linked together via a 4 K common platform. This paper discusses the status report on the thermodynamic performance of the 4 -10 K ADR. This ADR utilizes an Nb3Sn superconducting magnet and Gadolinium Gallium Garnet (GGG) as its refrigerant. Results show that an idealized cycle, one where its hold time at 4 K is equal to the recycle time, can lift 13 mW at 4 K with a hold time of 132 seconds.

CADR↗

Vibration-Heating in ADR Kevlar Suspension Systems

The cryogenics group at NASA's Goddard Space Flight Center has a long-standing development and test program for laboratory and space-flight adiabatic demagnetization refrigerators (ADRs). These devices are used to cool components to temperatures as low as 0.05 K. At such low temperatures the ADR systems can provide a few micro-Watts of cooling power, so it is important to minimize the conduction of heat to these cold stages from the surroundings. The cold ADR elements are held in place by thin tensioned strings made of Kevlar, chosen for its high strength and stiffness and low thermal conductivity. During laboratory testing, we have observed that occasional significant additional heat loads on the coldest ADR stages correlate with unusually high vibration levels in the cryostat due to a noisy mechanical cryocooler. We theorized that this heat results from plastic deformation of the Kevlar fibers and frictional interactions among them, driven by the cryostat vibrations. We describe tests and calculations performed in attempt to confirm this source of the heating, and we discuss possible strategies to reduce this effect in future ADR suspension systems.

Vibration-heating↗

Development of a Space-Flight ADR Providing Continuous Cooling at 50 mK with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 µT. We describe the cooling system here and report on the progress in its development.

Tuttle, Jim↗

Development of a Space-Flight ADR Providing Continuous Cooling at 50 mK with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 T. We describe the cooling system here and report on the progress in its development.

space-flight↗

Cryogenic Thermal Conductivity Measurements on Candidate Materials for Space Missions

Spacecraft and instruments on space missions are built using a wide variety of carefully-chosen materials. In addition to having mechanical properties appropriate for surviving the launch environment, these materials generally must have thermal conductivity values which meet specific requirements in their operating temperature ranges. Space missions commonly propose to include materials for which the thermal conductivity is not well known at cryogenic temperatures. We developed a test facility in 2004 at NASAs Goddard Space Flight Center to measure material thermal conductivity at temperatures between 4 and 300 Kelvin, and we have characterized many candidate materials since then. The measurement technique is not extremely complex, but proper care to details of the setup, data acquisition and data reduction is necessary for high precision and accuracy. We describe the thermal conductivity measurement process and present results for several materials.

thermal conductivity↗

A High-Resolution Measurement of Ball IR Black Paint's Low-Temperature Emissivity

High-emissivity paints are commonly used on thermal control system components. The total hemispheric emissivity values of such paints are typically high (nearly 1) at temperatures above about 100 Kelvin, but they drop off steeply at lower temperatures. A precise knowledge of this temperature-dependence is critical to designing passively-cooled components with low operating temperatures. Notable examples are the coatings on thermal radiators used to cool space-flight instruments to temperatures below 40 Kelvin. Past measurements of low-temperature paint emissivity have been challenging, often requiring large thermal chambers and typically producing data with high uncertainties below about 100 Kelvin. We describe a relatively inexpensive method of performing high-resolution emissivity measurements in a small cryostat. We present the results of such a measurement on Ball InfraRed BlackTM(BIRBTM), a proprietary surface coating produced by Ball Aerospace and Technologies Corp (BATC), which is used in spaceflight applications. We also describe a thermal model used in the error analysis.

Tuttle, Jim↗

Development of a Cryogenic Thermal Distortion Measurement Facility for Testing the James Webb Space Telescope Instrument Support Integration Module 2-D Test Assemblies

The James Webb Space Telescope Instrument Support Integration Module (ISIM) is being designed and developed at the Goddard Space Flight Center. The ISM Thermal Distortion Testing (ITDT) program was started with the primary objective to validate the ISM mechanical design process. The ITDT effort seeks to establish confidence and demonstrate the ability to predict thermal distortion in composite structures at cryogenic temperatures using solid element models. This-program's goal is to better ensure that ISIM meets all the mechanical and structural requirements by using test results to verify or improve structural modeling techniques. The first step to accomplish the ITDT objectives was to design, and then construct solid element models of a series 2-D test assemblies that represent critical building blocks of the ISIM structure. Second, the actual test assemblies consisting of composite tubes and invar end fittings were fabricated and tested for thermal distortion. This paper presents the development of the GSFC Cryo Distortion Measurement Facility (CDMF) to meet the requirements of the ISIM 2-D test. assemblies, and other future ISIM testing needs. The CDMF provides efficient cooling with both a single, and two-stage cryo-cooler. Temperature uniformity of the test assemblies during thermal transients and at steady state is accomplished by using sapphire windows for all of the optical ports on the radiation shields and by using .thermal straps to cool the test assemblies. Numerical thermal models of the test assemblies were used to predict the temperature uniformity of the parts during cooldown and at steady state. Results of these models are compared to actual temperature data from the tests. Temperature sensors with a 0.25K precision were used to insure that test assembly gradients did not exceed 2K lateral, and 4K axially. The thermal distortions of two assemblies were measured during six thermal cycles from 320K to 35K using laser interferometers. The standard deviation for all of the distortion measurements is less than 0.5 microns, which falls within the ISIM requirement of 3 microns.

Miller, Franklin↗

Development of a Cryogen-Free Continuous ADR for the Constellation-X Mission

Constellation-X is a multi-satellite x-ray astronomy mission presently being planned for launch in the 2010 time frame. Each of 4 identical satellites will contain a telescope and instruments for imaging and spectroscopic analysis of both hard and soft x-rays. The X- ray Microcalorimeter Spectrometer (XMS) instrument will use arrays of microcalorimeters to detect X-rays with energies from 0.2 to 6 keV. The technologies under development for this instrument include Transition-Edge Sensors (TES) with multiplexed SQUID readouts and NTD-Ge detectors with JFET readouts. Both will be operated at temperatures in the 50-60 mK range and both have a projected cooling power requirement of approximately 5 microwatts. In addition, in order to meet the lifetime requirement of 6 years (with a goal of 10 years), a mechanical cryocooler will be used to provide a heat sink for the low temperature cooler. The required performance is 20 mW at 6 K, with a goal of 4 K operation. In this paper we present the development status of an adiabatic demagnetization refigerator (ADR) that meets the cooling requirements of the X M S instrument. At present we have demonstrated a 4-stage ADR that operates continuously at 50 mK using a 4.2 K helium bath as a heat sink. The cooling power is 21 microwatts at 100 mK and 6 microwatts at 50 mK. Its efficiency when operating at 50 mK is 1 1 % of Carnot (accounting for all dissipation at 4.2 K and below, but not including power dissipation in the room temperature electronics), but this is expected to rise to 25% in the next generation system in which active gas-gap heat switches are replaced with passive devices. This will reduce the peak heat rejection rate of the ADR to less than 7 mW at 6 K. Details of the ADR s design and operation, as well as the development program leading up to a flight-qualified instrument, will be discussed.

Shirron, Peter↗

A Miniature Palladium-Iron Thermometer for Temperatures Down to 0.05 K

Magnetic thermometers are appealing at temperatures below about 0.1 Kelvin, because the avoid the noise self-heating problems associated with resistive thermometers. In practical, metallic dilute electronic thermometers add the advantages of chemical stability, high thermal conductivity, and easy in heat sinking work we describe a palladium-iron thermometer which was designed to be small and conveniently packaged and optimized for use at temperatures down to 0.05 Kelvin. The device showed Curie-Weiss behavior above about 0.06 Kelvin, and we achieve 41 nK/ square root of z temperature resolution at a temperature of 49 mK. We describe the design and operation of this thermometers and present the test results.

Tuttle, Jim↗

The XRS Low Temperature Cryogenic System: Ground Performance Test Results

The X-Ray Spectrometer (XRS) instrument is part of the Astro-E mission scheduled to launch early in 2000. Its cryogenic system is required to cool a 32-element square array of x-ray microcalorimeters to 60-65 mK over a mission lifetime of at least 2 years. This is accomplished using an adiabatic demagnetization refrigerator (ADR) contained within a two-stage superfluid helium/solid neon cooler. Goddard Space Flight Center is providing the ADR and helium dewar. The flight system was assembled in Sept. 1997 and subjected to extensive thermal performance tests. This paper presents test results at both the system and component levels. In addition, results of the low temperature topoff performed in Japan with the engineering unit neon and helium dewars are discussed.

Breon, Susan↗