Candela-Juan, C

Publications and source records attributed to Candela-Juan, C.

SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap

Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose rate distributions have been obtained for the applicators with and without the plastic cap. An experimental study using EBT3 radiochromic film has been realized in order to verify the Monte Carlo results. Results: The Monte Carlo simulations show that absorbed dose in the first millimeter of skin can increase up to 180% for the Valencia applicator if the plastic cap is absent and up to 1500% for the Leipzig applicators. At deeper distances the increase of dose is smaller being about 10–15%. Conclusion: Important differences have been found if the plastic cap of the applicators is absent in the treatment producing an overdosage in the skin. The user should have a checklist to remind him check always before HDR fraction delivery to insure the plastic cap is placed on the applicator. This work was supported in part by Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156, and by a research agreement with Elekta Brachytherapy, Veenendaal, The Netherlands.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-229: Craniospinal Radiotherapy Planning with VMAT, Two First Years Experience

Purpose: To describe how we moved to VMAT in the craniospinal radiotherapy planning process, the actual procedure details, and the results for the patients treated. Methods: Twelve patients underwent craniospinal irradiation with the new procedure, based on the paper by Lee et al. (IJROBP 82, 2012), with some additional modifications. Patients were treated in supine position in Varian Clinac iX linacs with 6 MV RapidArc; prescription doses ranged from 23.4 to 40 Gy (13 to 20 fractions); depending on the PTV length, 2 or 3 isocenters were used, all coordinates being equal except the longitudinal one, setting a few centimeter-long overlapping region; 2 arcs (RA) sharing isocentre for the cranial region, RA1 encompassing cranium and superior spinal region, and RA2 intended to improve conformity, only for cranium; for spine, 1 or 2 isocenters were employed; optimization was performed with Eclipse (V 13.0) using AAA algorithm, establishing sets of optimization parameters to give high conformity while sparing OAR. In pediatric patients, homogeneous irradiation of the vertebrae was also required.Conformity (CI) and heterogeneity (HI) indices (same as Lee et al.), and mean and maximum doses for OAR were calculated. Several pre-treatment verification methods were used: Octavius4D (PTW) for each isocentre, point dose at the junction region, Portal Dosimetry (when possible), and independent MU verification software (Diamond, PTW). Results: CI median value was 1.02 (0.99–1.07) and HI, 1.07 (1.06–1.09); a great reduction was observed for CI and OAR mean doses with respect to Lee et al. data; median maximum eye lens dose was 7.3 Gy (4.0–12.0); mean LungV20Gy was 1.9%; in children, vertebrae were homogeneously irradiated (D95%=20.8 Gy, Dmean= 23.2 Gy).All pre-treatment verifications were found within our action levels except for Portal Dosimetry. Conclusion: A RapidArc planning process for craniospinal axis irradiation has been implemented with significant advantages on conformity, homogeneity, feasibility and efficiency. and increase brain tissue sparing. Variations in volume decrease may be related to shape or location of the tumor.

60 APPLIED LIFE SCIENCES↗

SU-E-J-64: Evaluation of a Commercial EPID-Based in Vivo Dosimetric System in the Presence of Lung Tissue Heterogeneity

Purpose: To study the performance of Dosimetry Check (DC), an EPID-based dosimetry software, which allows performing transit dosimetry, in low density medium, by comparing calculations in-phantom, and analysing results for 15 lung patients. Methods: DC software (v.3.8, pencil beam-based algorithm) has been tested, for plans (Eclipse v.10.0 TPS) delivered in two Varian Clinac iX equipped with aS1000 EPIDs.In the CIRS lung phantom, comparisons between DC and Eclipse (Acuros) were performed for several plans: (1) four field box; (2) square field delivered in arc mode; (3) RapidArc lung patient plan medially centred; (4) RapidArc lung patient plan centred in one lung. Reference points analysed: P1 (medial point, plans 1–3) and P2 (located inside one lung, plan 4).For fifteen lung patients treated with RapidArc, the isocentre and 9 additional points inside the PTV as well as the gamma passing rate (3%/3mm) for the PTV and at the main planes were studied. Results: In-phantom:P1: Per-field differences in plan 1: good agreement for AP-PA fields; discrepancy of 7% for the lateral fields. Global differences (plans 1–3): about 4%, showing a compensating effect of the individual differences.P2: Global difference (plan 4): 15 %. This represents the worst case situation as it is a point surrounded by lung tissue, where the DC pencil beam algorithm is expected to give the greater difference against Acuros.Lung patients: Mean point difference inside the PTV:(5.4±4.2) %. Gamma passing rate inside the PTV:(45±12) %. Conclusion: The performance of DC in heterogeneous lung medium was studied with a special phantom and the results for 15 patients were analysed. The found deviations show that even though DC is a highly promising in vivo dosimetry tool, there is a need of incorporating a more accurate algorithm mainly for plans with low density regions involved.

60 APPLIED LIFE SCIENCES↗

SU-E-J-69: Evaluation of the Lens Dose On the Cone Beam IGRT Procedures

Purpose: With the establishment of the IGRT as a standard technique, the extra dose that is given to the patients should be taken into account. Furthermore, it has been a recent decrease of the dose threshold in the lens, reduced to 0.5 Gy (ICRP ref 4825-3093-1464 on 21st April, 2011).The purpose of this work was to evaluate the extra dose that the lens is receive due to the Cone-Beam (CBCT) location systems in Head-and-Neck treatments. Methods: The On-Board Imaging (OBI) v 1.5 of the two Varian accelerators, one Clinac iX and one True Beam, were used to obtain the dose that this OBI version give to the lens in the Head-and-Neck location treatments. All CBCT scans were acquired with the Standard Dose Head protocol (100 kVp, 80 mA, 8 ms and 200 degree of rotation).The measurements were taken with thermoluminescence (TLD) EXTRAD (Harshaw) dosimeters placed in an anthropomorphic phantom over the eye and under 3 mm of bolus material to mimic the lens position. The center of the head was placed at the isocenter. To reduce TLD energy dependence, they were calibrated at the used beam quality. Results: The average lens dose at the lens in the OBI v 1.5 systems of the Clinac iX and the True Beam is 0.071 and 0.076 cGy/CBCT, respectively. Conclusions: The extra absorbed doses that receive the eye lenses due to one CBCT acquisition with the studied protocol is far below the new ICRP recommended threshold for the lens. However, the addition effect of several CBCT acquisition during the whole treatment should be taken into account.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm{sup 3} sized ion chambers covering 11×11 cm{sup 2}, which spacing is 2.5 mm in the central 5.5×5.5 cm{sup 2}, dedicated mainly in principle, in conjunction with Octavius 4D (PTW), to IMRT, VMAT, SBRT verifications. Verisoft software that allows for 3D and planar analysis has been used to evaluate the results. Applicators were located on the surface of the array. To verify the SID, measurements corresponding to the reference value, SID ± 1 mm and SID ± 2 mm were acquired (integration time was fixed in order to discard the influence of the source entrance/exit). Once SID was determined, standard protocol treatments corresponding to 3 Gy and 7 Gy were acquired in order to establish typical patient dose distribution. Results: The method is fast and sensitive. The SID obtained was 1321 mm which is the nominal value included in the applicator manual. For example at 1319 mm an asymmetry of ±8% with respect to the central value was measured, along with a central deviation of −4% referred to 1321 mm. Conclusion: A practical method for the commissioning and QA of Valencia applicators has been described. It has been shown that it is an efficient and accurate tool for these purposes as well as for the verification of the absolute output constancy.

60 APPLIED LIFE SCIENCES↗