Search NASA⌕ Search

Engineering topics

Cantor, Robin

Publications and source records attributed to Cantor, Robin.

Shake-up and shake-off spectra in the electron capture decay of atomic $^7$Be

The most stringent laboratory-based experimental limits on the existence of sub-MeV sterile neutrinos are currently set by decay spectroscopy of radioactive $^7$Be embedded into superconducting sensors. The systematic uncertainties are dominated by the modeling of the electron shake-up and shake-off spectra that are not based on state-of-the-art atomic theory and do not include electron correlations or relativistic effects. We have used the multiconfiguration Dirac-Fock formalism to obtain correlated wavefunctions ab initio and compute all single and double shake processes in the electron capture decay of atomic $^7$Be. The simulations can explain some but not all of the observed spectral features, likely because the wave functions are modified by the Ta sensor material that the $^7$Be is embedded into. The new models also show that the L/K electron capture ratio of $^7$Be in Ta has previously been slightly underestimated revising the previous value of 0.070(7) to a new value of 0.0756(20).

Atomic Physics (physics.atom-ph)↗

Development of the Nano-HEB Array for Low-Background Far-IR Applications

We present an overview of the recent progress made in the development of a far-IR array of ultrasensitive hot-electronnanobolometers (nano-HEB) made from thin titanium (Ti) films. We studied electrical noise, signal and noisebandwidth, single-photon detection, optical noise equivalent power (NEP), and a microwave SQUID (MSQUID) basedfrequency domain multiplexing (FDM) scheme. The obtained results demonstrate the very low electrical NEP down to1.5x10-(sup 2)? W/Hz(sup 1)/(sup 2) at 50 mK determined by the dominating phonon noise. The NEP increases with temperature as ~ T(sup 3)reaching ~ 10-(sup 1)? W/Hz(sup 1)/(sup 2) at the device critical temperature TC = 330-360 mK. Optical NEP = 8.6x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 357mK and 1.4x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 100 mK respectively, agree with thermal and electrical data. The optical couplingefficiency provided by a planar antenna was greater than 50%. Single 8-?m photons have been detected for the first timeusing a nano-HEB operating at 50-200 mK thus demonstrating a potential of these detectors for future photon-countingapplications in mid-IR and far-IR. In order to accommodate the relatively high detector speed (~ ?s at 300 mK, ~ 100 ?sat 100 mK), an MSQUID based FDM multiplexed readout with GHz carrier frequencies has been built. Both the readoutnoise ~ 2 pA/Hz(sup 1)/(sup 2) and the bandwidth > 150 kHz are suitable for nano-HEB detectors.

single-photon↗