Engineering topics
Cao, Yuhe
Publications and source records attributed to Cao, Yuhe.
Synergistic Tuning of Microstructure and Morphology in Carbon Molecular Sieve Hollow Fibers for Propylene/Propane Separation
Abstract Asymmetric carbon molecular sieve (CMS) hollow fiber membranes with tunable micro‐ and macro‐structural morphologies for energy efficient propylene‐propane separation are reported here. A sub‐glass transition temperature (sub‐Tg) thermal oxidative crosslinking strategy enables simultaneous optimization of the intrinsic molecular sieving properties while also reducing the thickness of the CMS “skin” derived from the 6FDA : BPDA/DAM polyimide precursors. Such synergistic tuning of CMS microstructure and macroscopic morphology of CMS hollow fibers enables significantly increased propylene permeance (reaching 186.5 GPU) while maintaining an appealing propylene/propane selectivity of 13.3 for 50/50 propylene/propane mixed gas feeds. Our findings reveal a more refined and versatile tool than available with previous O 2 ‐doping pretreatments. The advanced approach here should be broadly useful to other polyimide precursors and diverse gas pairs.
Above‐T g Annealing Benefits in Nanoparticle‐Stabilized Carbon Molecular Sieve Membrane Pyrolysis for Improved Gas Separation
Abstract Nanoparticles can suppress asymmetric precursor support collapse during pyrolysis to create carbon molecular sieve (CMS) membranes. This advance allows elimination of standard sol‐gel support stabilization steps. Here we report a simple but surprisingly important thermal soaking step at 400 °C in the pyrolysis process to obtain high performance CMS membranes. The composite CMS membranes show CO 2 /CH 4 (50 : 50) mixed gas feed with an attractive CO 2 /CH 4 selectivity of 134.2 and CO 2 permeance of 71 GPU at 35 °C. Furthermore, a H 2 /CH 4 selectivity of 663 with H 2 permeance of 240 GPU was achieved for promising green energy resource‐H 2 separation processes.
Above‐T g Annealing Benefits in Nanoparticle‐Stabilized Carbon Molecular Sieve Membrane Pyrolysis for Improved Gas Separation
Nanoparticles can suppress asymmetric precursor support collapse during pyrolysis to create carbon molecular sieve (CMS) membranes. This advance allows elimination of standard sol-gel support stabilization steps. Here we report a simple but surprisingly important thermal soaking step at 400 °C in the pyrolysis process to obtain high performance CMS membranes. The composite CMS membranes show CO 2 /CH 4 (50 : 50) mixed gas feed with an attractive CO 2 /CH 4 selectivity of 134.2 and CO 2 permeance of 71 GPU at 35 °C. Furthermore, a H 2 /CH 4 selectivity of 663 with H 2 permeance of 240 GPU was achieved for promising green energy resource-H 2 separation processes.
Appealing sheath‐core spun high‐performance composite carbon molecular sieve membranes
Abstract Carbon molecular sieve (CMS) membranes are attractive candidates to meet requirements for challenging gas separations. The added ability to maintain such intrinsic properties in an asymmetric morphology with a structure that we term a “Pseudo Wheel+Hub & Spoke” asymmetric form offers new opportunities. For CMS membrane, specifically, the structure provides both selective layer support and low flow resistance even for high feed pressures and fluxes in CO 2 removal from natural gas. This capability is unavailable to even rigid glassy polymers due to the much higher modulus of CMS materials. Combining precursor asymmetric hollow fiber formation and optimized pyrolysis creates a defect free CMS proof‐of‐concept membrane for this application. Facile formation of the sheath‐core spun precursor with a 6FDA‐DAM sheath and Matrimid® core also avoids the need to seal defects before or after the carbonization of the precursors. The composite CMS membrane shows CO 2 /CH 4 (50 : 50) mixed gas feed with an attractive CO 2 /CH 4 selectivity of 64.3 and CO 2 permeance of 232 GPU at 35 °C. A key additional benefit of the approach is reduction in use of the more costly high performance 6FDA‐DAM in a composite sheath‐core CMS membrane with the “Pseudo Wheel+Hub & Spoke” structure.
Appealing sheath-core spun high-performance composite carbon molecular sieve membranes
Carbon molecular sieve (CMS) membranes are attractive candidates to meet requirements for challenging gas separations. The added ability to maintain such intrinsic properties in an asymmetric morphology with a structure that we term a “Pseudo Wheel+Hub & Spoke” asymmetric form offers new opportunities. For CMS membrane, specifically, the structure provides both selective layer support and low flow resistance even for high feed pressures and fluxes in CO 2 removal from natural gas. Further, this capability is unavailable to even rigid glassy polymers due to the much higher modulus of CMS materials. Combining precursor asymmetric hollow fiber formation and optimized pyrolysis creates a defect free CMS proof-of-concept membrane for this application. Facile formation of the sheath-core spun precursor with a 6FDA-DAM sheath and Matrimid® core also avoids the need to seal defects before or after the carbonization of the precursors. The composite CMS membrane shows CO 2 /CH 4 (50 : 50) mixed gas feed with an attractive CO 2 /CH 4 selectivity of 64.3 and CO 2 permeance of 232 GPU at 35 °C. A key additional benefit of the approach is reduction in use of the more costly high performance 6FDA-DAM in a composite sheath-core CMS membrane with the “Pseudo Wheel+Hub & Spoke” structure.
Continuous electrocoagulation-membrane distillation unit for treating hydraulic fracturing produced water
Hydraulic fracturing oil and gas produced water is frequently highly impaired. While it is often deep well injected, there is great interest in treating this water for beneficial uses. Given the complexity of these produced waters, multiple unit operations are necessary. Electrocoagulation has been considered as a promising pretreatment technology. Here electrocoagulation is considered as a pretreatment prior to membrane distillation. The focus of this work is on understanding the electrocoagulation process in order to design an integrated unit operation. Electrocoagulation is used to remove organic compounds that will foul the membrane leading to membrane failure during membrane distillation. Using aluminum or iron electrodes, half-cell reactions in the electrocoagulation cell and electrode potentials have been calculated. Electrocoagulation was conducted using a continuous electrocoagulation reactor with actual produced water using aluminum, iron or mixed aluminum and iron electrodes. Here, the results obtained here indicate that electrocoagulation can obtain good removal efficiency of total organic carbon (TOC) by using different reaction conditions. Removal of organic compounds is essential to minimize fouling during membrane distillation. Further the performance of the electrocoagulation process depends strongly on the quality of the feed water. Insoluble species were more effectively coagulated than dissolved organic species. Continuous electrocoagulation shows great potential as a scalable unit operation for pretreating hydraulic fracturing produced water.
Carbon molecular sieve hollow fiber membranes derived from dip-coated precursor hollow fibers comprising nanoparticles
We report a novel approach to economically fabricate dual-layer composite nanoparticle-containing carbon molecular sieve (CMS) hollow fiber membranes having excellent gas separation performance. The economically favored process comprises dip coating engineered support layer fibers to form a dense skin layer in a CMS precursor. The coated fibers are then pyrolyzed to form a high-performance CMS hollow fiber membrane. The nano-particle containing composite carbon molecular sieve hollow fiber membranes showed very attractive selectivities and productivities. As a result, this work shows how to produce high performance CMS hollow fiber membrane by coating, which exceeds that achieved with the standard sol-gel support stabilization technique.
Combined electrocoagulation-microfiltration-membrane distillation for treatment of hydraulic fracturing produced water
Hydraulic fracturing flowback and produced water is a highly impaired wastewater containing dissolved salts polar and non-polar organic compounds, oil and surfactants. Here a combined electrocoagulation - microfiltration – membrane distillation process has been used to treat this wastewater. Electrocoagulation followed by microfiltration was used to pretreat the wastewater prior membrane distillation. The initial total dissolved solids (TDS) concentration was extremely high being 245,300 mg L -1 . After electrocoagulation, the total organic carbon (TOC) was reduced from 120 mg L -1 to 64 mg L -1 . Tangential flow microfiltration using a 0.1 μm pore size polyethersulfone membrane was used to separate the particulate matter after electrocoagulation and to further reduce the TOC to 44 mg L -1 . Membrane distillation was used to desalinate the pretreated produced water resulting in a high quality treated water (TDS of 56 mg L -1 and TOC 1 mg L -1 ). Three membranes with very different surface morphology were used: commercially available polyvinylidene fluoride, electrospun poly(vinylidene fluoride-co-hexafluoropropylene) nanofibers and multiwalled carbon nanotube coated polytetrafluoroethylene. The TDS in the retentate increased to over 350,000 mg L -1 . During membrane distillation, the temperature of the feed tank was maintained at 36 °C while the feed entered the module at 60 °C in order to minimize scaling on the membrane. The surface properties of an ideal membrane that is resistant to wetting and provides high flux is likely to depend on the TDS and properties of the wastewater.