Search NASA⌕ Search

Engineering topics

Carlson, Carl A.

Publications and source records attributed to Carlson, Carl A..

The Dynamic Response of Polymers Interrogated by 3rd Generation X-ray Light Sources

Future predictive models of materials response under extreme conditions will be increasingly phaseand microstructure-aware. As such, model development and validation will require new types of experimental data that probe responses at lattice-to-mesoscales in real time during dynamic events. High brilliance X-ray light sources coupled to dynamic driver platforms offer tremendous potential for providing new insights into the physics of materials under dynamic conditions. Over the last several years, data from burgeoning facilities are already challenging historical model assumptions in several areas.

36 MATERIALS SCIENCE↗

Beam Profile Measurements at the DARHT II Accelerator Exit

Measurements of the beam profile at the exit of the DARHT II accelerator have been made. The 1.65-kA, 17-MeV DARHT-II linear induction accelerator [1] is unique in that its beam pulse has a long, 1.6-ns flattop during which the kinetic energy varies by less than ±2%. Four short pulses are selected out of this long pulse in the downstream transport [2], and these are converted to bremsstrahlung for multi-pulse flash radiography of high explosive driven hydrodynamic experiments. The objective of the measurements was to demonstrate the capability to make these measurements with a long beam pulse of high intensity. Many observations can be made on the basis of these measurements. These are described herein.

43 PARTICLE ACCELERATORS↗

Dynamic Exploding Foil Initiator Imaging at the Advanced Photon Source

Recent advances in diagnostics coupled with synchrotron sources have allowed the in-situ investigation of exploding foil initiators (EFI) during flight. Herein, we present the first images of EFIs during flight utilizing x-ray phase contrast imaging at the Advanced Photon Source (APS) located in Argonne National Laboratory. These images have provided the DOE/DoD community with unprecedented images resolving details on the micron scale of the flyer formation, plasma instabilities and in-flight characteristics along with the subsequent interaction with high explosives on the nanosecond time scale. Phase contrast imaging has allowed the ability to make dynamic measurements on the length and time scale necessary to resolve initiator function and provide insight to key design parameters. These efforts have also probed the fundamental physics at “burst” to better understand what burst means in a physical sense, rather than the traditional understanding of burst as a peak in voltage and increase in resistance. This fundamental understanding has led to increased knowledge on the mechanisms of burst and has allowed us to improve our predictive capability through magnetohydrodnamic modeling. This manuscript presents results from several EFI designs along with a look to the future for upcoming work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equation of State and Damage in Polyethylene

The dynamic response of polymers differs significantly from those of metals, upon which many of the National Laboratories' deformation, damage, and failure models are based. Their moduli, yield strength, and damage characteristics are highly strain rate-, temperature-, and phase-dependent, requiring models that encompass a wide range of phenomena including some not in equilibrium. Recently, Los Alamos developed the Glassy Amorphous Polymer (GAP) 1 model [1] to address limitations in existing models of polymer deformation. GAP captures both volumetric (equation of state) and deviatoric (shear) response, including a non-equilibrium component to the former (a feature determined to be crucial in capturing the low-pressure, viscoelastic response to impact loading). GAP has already been applied to polymers such as PMMA, PTFE, epoxy, and Kel-F 800, but with an emphasis on impact response as opposed to damage or failure. The current effort was launched to address this gap in predictive capability. For reasons that will be made clear, semi-crystalline polyethylene (PE) was chosen to serve as a model system for parameterization and validation. PE (-C 2 H 4- )n is one of the most widely used polymers in industrial and engineering contexts, chiey due to the versatility of its mechanical response. This response can be tuned through network and chain structure, degree of crystallinity, and molecular weight. PE is found in several forms including low density (LDPE), high density (HDPE), and ultra-high molecular weight (UHMWPE). The focus here was on HDPE and UHMWPE, of pedigree described in the following section. Materials were well-characterized prior to study and are representative of semi-crystalline polymers of interest to DOE and DoD. Semi-crystalline PE undergoes a glass transition at low temperature (-35°C) and melts across a range of moderate temperatures (~80-180°C), depending on its structure. It is typically inert chemically, has low strength and high ductility, and the high strength and anisotropy of UHMWPE ber, in particular, have driven its use in engineering, impact, and armor applications. Surprisingly little is known, however, about the influence of PE's crystalline structure and associated phase transitions (including melt) on its response to dynamic compression. A broad suite of experiments was used to calibrate the GAP model for HDPE and UHMWPE. Section IV examines the effects of tensile strain on the structure and integrity of PE crystalline domains. These data were used to inform the preliminary damage model described in Section XII, whose roots lie in statistical physics and network theory. The viscoelastic and plastic components of GAP rely heavily on the stress-strain data of Section VI, which also include dynamic extrusion and Taylor anvil experiments used to validate the damage model. The thermal data of Section X provide crucial inputs to the equilibrium EOS in GAP, as well as the much broader range SESAME EOS whose construction is outlined in Section XI. Section VII details plate impact experiments characterizing the low-pressure shock locus and failure (spall) using in situ electromagnetic gauges. A previously reported \cusp" in the principal Hugoniot near 0.5 kbar was confirmed, and a multi-wave structure was observed over a limited input stress range above the cusp. This cusp is believed due to solid-solid phase transitions associated with the crystalline domains of the polymer.

36 MATERIALS SCIENCE↗

Retuning the DARHT Axis-II Linear Induction Accelerator

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility uses bremsstrahlung radiation source spots produced by the focused electron beams from two linear induction accelerators (LIAs) to radiograph large hydrodynamic experiments driven by high explosives. The Axis-II 1.7-kA, 1600-ns beam pulse is transported through the LIA by the magnetic field from 91 solenoids as it is accelerated to ~16.5 MeV. The magnetic field produced by the solenoids and 80 steering dipole pairs for a given set of magnet currents is known as the “tune” of the accelerator [1]. From June, 2013 through September, 2014 a single tune was used. This tune was based on measurements of LIA element positions made over several years [2], and models of solenoidal fields derived from actual field measurements [3] [4]. Based on the focus scan technique, changing the tune of the accelerator and downstream transport had no effect on the beam emittance, to within the uncertainties of the measurement. Beam sizes appear to have been overestimated in all prior measurements because of the low magnification of the imaging system. This has resulted in overestimates of emittance by ~50%. The high magnification imaging should be repeated with the old tune for direct comparison with the new tune. High magnification imaging with the new accelerator tune should be repeated after retuning the downstream to produce a much more symmetric beam to reduce the uncertainty of this measurement. Thus, these results should be considered preliminary until we can effect a new tune to produce symmetric spots at our imaging station, for high magnification images.

43 PARTICLE ACCELERATORS↗