Self‐Potential Tomography Preconditioned by Particle Swarm Optimization—Application to Monitoring Hyporheic Exchange in a Bedrock River

Abstract A self‐potential (SP) data‐inversion algorithm was developed and tested on an analytical model of electrical‐potential profile data attributed to single and multiple polarized electrical sources. The developed algorithm was then validated by an application to SP‐monitoring field data measured on the floodplain of East Fork Poplar Creek, Oak Ridge, Tennessee, to image electrical sources in areas conducive to preferential flow into the flood plain from the bedrock‐lined riverbed. The algorithm combined stochastic source‐localization by particle‐swarm‐optimization (PSO) of electrical sources characterized by simplified geometries with source tomography by regularized weighted least‐squares minimization of a quadratic objective function. Prior information was incorporated by preconditioning the tomography algorithm by PSO results. Variable percentages of random noise were added to analytical‐model data to evaluate the algorithm performance. Results indicated that true parameters of single‐source models were inverted and approximated with small residual error, whereas inversion of analytical‐model data representing multiple electrical sources accurately approximated the locations of the sources but miscalculated some parameters because of the non‐uniqueness of the inverse‐model solution. Source tomography applied to analytical model data during testing produced a spatially continuous parameter field that identified the locations of point‐scale synthetic dipole sources of electrical current flow with varying degrees of accuracy depending on the prior information incorporated into the tomography. When applied to SP‐monitoring field data, the algorithm imaged electrical sources within a known fault that intersects the bedrock riverbed and flood plain of East Fork Poplar Creek and depicted dynamic electrical conditions attributed to hyporheic exchange.

54 ENVIRONMENTAL SCIENCES↗

Comparison of machine learning and electrical resistivity arrays to inverse modeling for locating and characterizing subsurface targets

Here, this study evaluates the performance of multiple machine learning (ML) algorithms and electrical resistivity (ER) arrays for inversion with comparison to a conventional Gauss-Newton numerical inversion method. Four different ML models and four arrays were used for the estimation of only six variables for locating and characterizing hypothetical subsurface targets. The combination of dipole-dipole with Multilayer Perceptron Neural Network (MLP-NN) had the highest accuracy. Evaluation showed that both MLP-NN and Gauss-Newton methods performed well for estimating the matrix resistivity while target resistivity accuracy was lower, and MLP-NN produced sharper contrast at target boundaries for the field and hypothetical data. Both methods exhibited comparable target characterization performance, whereas MLP-NN had increased accuracy compared to Gauss-Newton in prediction of target width and height, which was attributed to numerical smoothing present in the Gauss-Newton approach. MLP-NN was also applied to a field dataset acquired at U.S. DOE Hanford site.

54 ENVIRONMENTAL SCIENCES↗

Geoelectric Characterization of Hyporheic Exchange Flow in the Bedrock‐Lined Streambed of East Fork Poplar Creek, Oak Ridge, Tennessee

Abstract A multimethod geoelectric survey was implemented between January and March 2022 along a 220‐m long reach of the bedrock‐lined streambed of East Fork Poplar Creek in Oak Ridge, Tennessee to identify locations of surface‐water and groundwater exchange and characterize the subsurface flow paths that convey water between the stream and flood plain. A waterborne self‐potential (WaSP) survey was completed in January 2022 to measure the electric streaming‐potential field in the stream. Electric resistivity tomography (ERT) was performed in March 2022 on the flood plain adjacent to the WaSP survey reach to map the electric resistivity distribution and characterize the hydrogeology and subsurface flow paths that facilitate surface‐water and groundwater exchange in the bedrock‐lined stream. The combination of WaSP and ERT data support the qualitative interpretation that surface‐water and groundwater exchange likely occurs along fractures in outcropping bedrock and along two fault lines that intersect the limestone creek bed.

54 ENVIRONMENTAL SCIENCES↗

Transient Storage Model Parameter Optimization Using the Simulated Annealing Method

Hyporheic exchange in streams is critical to ecosystem functions such as nutrient cycling along river corridors, especially for slowly moving or small stream systems. The transient storage model (TSM) has been widely used for modeling of hyporheic exchange. TSM calibration, for hyporheic exchange, is typically used to estimate four parameters, including the mass exchange rate coefficient, the dispersion coefficient, stream cross-sectional area, and hyporheic zone cross-sectional area. Prior studies have raised concerns regarding the non-uniqueness of the inverse problem for the TSM, that is, the occurrence of different parameter vectors resulting in TSM solution that reproduces the observed in-stream tracer break through curve (BTC) with the same error. This leads to practical non-identifiability in determining the unknown parameter vector values even when global-optimal values exist, and the parameter optimization becomes practically non-unique. To address this problem, we applied the simulated annealing method to calibrate the TSM to BTCs, because it is less susceptible to local minima-induced non-identifiability. A hypothetical (or synthetic) tracer test data set with known parameters was developed to demonstrate the capability of the simulated annealing method to find the global minimum parameter vector, and it identified the “hypothetically-true” global minimum parameter vector even with input data that were modified with up to 10% noise without increasing the number of iterations required for convergence. The simulated annealing TSM was then calibrated using two in-stream tracer tests conducted in East Fork Poplar Creek, Tennessee. In conclusion, simulated annealing was determined to be appropriate for quantifying the TSM parameter vector because of its search capability for the global minimum parameter vector.

54 ENVIRONMENTAL SCIENCES↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

The Co-Transport of PFAS and Cr(VI) in porous media

PFAS and Cr are present at some sites as co-contaminants. Here, the objective of this research was to investigate the co-transport behavior of per- and polyfluoroalkyl substances (PFAS) and hexavalent chromium (Cr(VI)) in porous media. Miscible-displacement experiments were conducted using two soils and an aquifer sediment with different geochemical properties. Perfluorooctane sulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) were employed as model PFAS. The retardation of PFOS was decreased in the presence of Cr(VI). Conversely, the transport and retardation of PFOA was not affected by the presence of Cr(VI). The reduction of PFOS retardation caused by Cr(VI) is likely due to sorption competition for both organic-carbon and inorganic (metal-oxides and clay minerals) domains. The relative contributions of the three soil constituents to PFOS sorption and the potential for competition between PFOS and Cr(VI) is a function of the geochemical composition of the porous media (i.e., organic carbon, metal-oxides and clay minerals). The PFAS had minimal impact on the retention and transport of Cr(VI). To our knowledge, the results presented herein represent the first reported data for PFOS and Cr(VI) co-transport in porous media. The results of this study indicate that the presence of Cr(VI) has the potential to increase the migration potential of PFOS in soil and groundwater, which should be considered when characterizing electroplating facilities, leather tanning facilities, and other co-contaminated sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗