Heat Treatment Effects on Creep, Tensile, and Microstructural Behavior of Additively Manufactured Titanium Alloys
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Casias, Zachary.
Explore the source record for details and available documents.
This is the seminar I will present at WCCM conference highlighting our latest research work on incorporating genetic programming to obtain data-driven strength models for complex materials.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Not Available
Abstract not provided.
Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.
Abstract not provided.
This report documents details of the microstructure and mechanical properties of -tin (Sn), that is used in the Tri-lab (Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratories (SNL)) collaboration project on Multi-phase Tin Strength. We report microstructural features detailing the crystallographic texture and grain morphology of as-received -tin from electron back scatter diffraction (EBSD). Temperature and strain rate dependent mechanical behavior was investigated by multiple compression tests at temperatures of 200K to 400K and strain rates of 0.0001 /s to 100 /s. Tri-lab tin showed significant temperature and strain rate dependent strength with no significant plastic anisotropy. A sample to sample material variation was observed from duplicate compression tests and texture measurements. Compression data was used to calibrate model parameters for temperature and rate dependent strength models, Johnson-Cook (JC), Zerilli-Armstrong (ZA) and Preston-Tonks-Wallace (PTW) strength models.
Abstract not provided.
Lithium-metal anodes can theoretically enable 10x higher gravimetric capacity than conventional graphite anodes. However, Li-metal anode cycling has proven difficult due to porous and dendritic morphologies, extensive parasitic solid electrolyte interphase reactions, and formation of dead Li. We systematically investigate the effects of applied interfacial pressure on Li-metal anode cycling performance and morphology in the recently developed and highly efficient 4 M lithium bis(fluorosulfonyl)imide in 1,2-dimethoxyethane electrolyte. We present cycling, morphology, and impedance data at a current density of 0.5 mA/cm 2 and a capacity of 2 mAh/cm 2 at applied interfacial pressures of 0, 0.01, 0.1, 1, and 10 MPa. Cryo-focused ion beam milling and cryo-scanning electron microscopy imaging in cross section reveal that increasing the applied pressure during Li deposition from 0 to 10 MPa leads to greater than a fivefold reduction in thickness (and therefore volume) of the deposited Li. This suggests that pressure during cycling can have a profound impact on the practical volumetric energy density for Li-metal anodes. A “goldilocks zone” of cell performance is observed at intermediate pressures of 0.1–1 MPa. Increasing pressure from 0 to 1 MPa generally improves cell-to-cell reproducibility, cycling stability, and Coulombic efficiency. However, the highest pressure (10 MPa) results in high cell overpotential and evidence of soft short circuits, which likely result from transport limitations associated with increased pressure causing local pore closure in the separator. All cells exhibit at least some signs of cycling instability after 50 cycles when cycled to 2 mAh/cm 2 with thin 50 μm Li counter electrodes, though instability decreases with increasing pressure. In contrast, cells cycled to only 1 mAh/cm 2 perform well for 50 cycles, indicating that capacity plays an important role in cycling stability.
Abstract not provided.
The present invention features a metamaterial including a plurality of unit cells, in which each unit cell includes two interacting members to dissipate energy. Also provided herein are assemblies including such metamaterials and methods of manufacture.