Search NASA⌕ Search

Engineering topics

Caulet, Adeline

Publications and source records attributed to Caulet, Adeline.

Ly alpha and IR galaxy companions of high redshift damped Ly alpha QSO absorbers

We have used a Near-Infrared Camera and Multi-Object Spectrometer (NICMOS3) HgCdTe 256x256 array detector with the Infrared (IR) camera on the 2.3m telescope at Steward Observatory to image several Quasi-Stellar Object (QSO) fields. The limiting magnitude is K'(2.1 microns) = 21.0 - 21.5 mag per square arcsec for a 3 sigma detection in 3 hours of in-field chopping observations. Each QSO line-of-sight samples several known absorbers with Mg2(lambda)2796-2803 A and/or C4(lambda)1548-1551 A absorption doublets. The equivalent width distributions of the low and high ionization absorption lines of the absorber sample are identical to those of the parent population of all absorbers. This selection process, used already for a spectroscopic survey of Mg2 absorption lines in C4-selected absorption systems at high z, gives a methodical approach to observing, reduces the observer biases, and makes a more efficient use of telescope time. This selection guarantees that imaging of the sample of QSO fields will provide complete sampling of the whole population of high z QSO absorbers. Follow-up optical and IR spectroscopy of these objects is scheduled for redshift measurement and confirmation of the absorbing galaxies and the cluster members.

Caulet, Adeline↗

Fabry-Perot images of NGC 1275 and its puzzling high-velocity system

The Fabry-Perot imager is used to obtain a velocity sequence of calibrated narrow-band CCD images to cover 3000 km/s velocity space between the redshifted H-alpha emission lines of NGC 1275, its extended associated system of low-velocity (LV) filaments, and the high-velocity (HV) system of knots, projected on the same line of sight in the sky. The lack of intermediate-velocity emission-line gas between the two systems leads to an upper limit of 1.5 x 10 exp -16 ergs/sq cm s sq arcsec (3 sigma) on stripped ionized gas due to the dynamical interaction between NGC 1275 and its HV companion galaxy. It also confirms previous reports that the level of continuum light arising from stellar and nonstellar sources must be very low in otherwise bright, strongly concentrated emission-line knots with unresolved diameters of 425/h pc. The H-alpha luminosities of the emission-line regions of the two systems were measured and star formation rates derived in order to investigate quantitatively the physical relation between the HV galaxy, NGC 1275, and the surrounding cooling flow filaments.

Caulet, Adeline↗

Discovery of a Ly-alpha galaxy near a damped Ly-alpha absorber at z = 2.3

The detection of a galaxy associated with the damped Ly-alpha absorbing cloud seen at z = 2.309 toward the QSO PHL 957 is reported. In addition to a strong but narrow Ly-alpha emission line and weaker C IV and He II lines, the object shows continuum at V about 24, with a slope rising slightly toward the red. This is similar to what is seen in high-redshift radio galaxies, but this galaxy does not correspond to any known radio source. The detected emission lines and continuum are most easily interpreted as light from hot, recently formed stars, implying a sizable star formation rate and a scarcity of dust. The spatial correlation of the absorbing cloud and the companion galaxy supports the interpretation of damped Ly-alpha clouds as objects fundamentally different from the lower column density Ly-alpha forest clouds, which show weak or no clustering.

Lowenthal, James D.↗

Interstellar absorption lines in the galaxy NGC 1705

The possibility is considered, and shown to be plausible, that the strong C IV and Si IV absorption lines in low-resolution ultraviolet spectra of gas-rich dwarf galaxies are primarily interstellar, not stellar as has been supposed. The argument is based on analogies with H II regions in the Local Group, on low-resolution equivalent width measurements of gas-rich dwarf galaxies from the literature and on high-resolution UV spectra of NGC 1705.

York, Donald G.↗

The evolution of low ionization QSO absorption systems

A CCD spectroscopic survey of Mg II and Mg I absorption lines in a C IV selected sample of 35 metal systems, observed toward 12 QSOs between z = 1.1 and z = 2.1, is reported. Six Mg I and 10 Mg II absorption lines are detected in 33 C IV clouds, and some peculiarities are noted. The complex or asymmetric line profiles reveal that multiple components are present and that variations in the C IV/Mg II and Mg II/Mg I ratio may occur often from one component to another with a velocity separation less than the velocity resolution of about 100 km/s. Comparison with the Mg II absorption-line statistics at z-bar = 0.5 implies that, at z-bar = 1.6, there are more strong absorbers per unit z with W(2796) greater than 0.6 A and fewer weak absorbers. The evolutionary parameter gamma appears to depend on W(min): its value drops as W(min) is reduced and is negative at W(min) = 0.15 A. This suggests a different redshift evolution for the population of weak and strong Mg II absorbers.

Caulet, Adeline↗