Search NASA⌕ Search

Engineering topics

Celik, Cihangir

Publications and source records attributed to Celik, Cihangir.

49 records · Page 3

Software Quality Assurance and Verification for the MPACT Library Generation Process

This report fulfills the requirements for the Consortium for the Advanced Simulation of Light-Water Reactors (CASL) milestone L2:RTM.P14.02, “SQA and Verification for MPACT Library Generation,” by documenting the current status of the software quality, verification, and acceptance testing of nuclear data libraries for MPACT. It provides a brief overview of the library generation process, from general-purpose evaluated nuclear data files (ENDF/B) to a problem-dependent cross section library for modeling of light-water reactors (LWRs). The software quality assurance (SQA) programs associated with each of the software used to generate the nuclear data libraries are discussed; specific tests within the SCALE/AMPX and VERA/XSTools repositories are described. The methods and associated tests to verify the quality of the library during the generation process are described in detail. The library generation process has been automated to a degree to (1) ensure that it can be run without user intervention and (2) to ensure that the library can be reproduced. Finally, the acceptance testing process that will be performed by representatives from the Radiation Transport Methods (RTM) Focus Area prior to the production library’s release is described in detail.

97 MATHEMATICS AND COMPUTING↗

NCSP FY 2015 AMPX Annual Report

The objective of the Nuclear Criticality Safety Program (NCSP) Analytical Methods program element is to sustain state-of-the-art radiation transport modeling capabilities and the expertise necessary to develop, maintain, and disseminate the analytical tools and data libraries in a manner that is responsive to the needs of those responsible for developing, implementing, and maintaining criticality safety. To this end, the objective of the AMPX Development and Maintenance Subtask is to ensure that the AMPX cross-section processing system is available to prepare cross-section and covariance libraries that are needed by SCALE and other radiation transport packages to support criticality safety analyses of systems with fissionable material. Moreover, the task ensures that the cross-section processing software is current and up-to-date with the Evaluated Nuclear Data File (ENDF/B) formats and procedures for disseminating evaluated cross-section data provided through new measurement and evaluation work efforts. The AMPX subtask provides for the production of data libraries needed for criticality safety analyses. As such, the task provides the “bridge” between the nuclear data evaluations and the radiation transport software. In the absence of the AMPX cross-section processing task, the ability to maintain and update the SCALE nuclear data libraries (cross-section and covariance data) would be hindered. Therefore, the AMPX Development and Maintenance Subtask ensures that SCALE is up-to-date with the latest cross-section data for supporting criticality safety analyses. This letter report provides a summary of the FY 2015 AMPX development and maintenance activities that have been performed in support of the NCSP. Specifically, the report summarizes the AMPX code system updates and modernization accomplishments that have been made to the software package. Also, the report documents the cross-section library updates that have been made for the SCALE radiation transport package. In addition, the report documents testing activities that have been performed to process available cross-section and covariance data files to ensure the latest ENDF/B data files can be processed properly. This report satisfies the following reporting milestone in the NCSP FY16-20 Five Year Plan: Document AMPX modernization and technical support for SCALE continuous energy (CE), multigroup (MG), and covariance libraries and report status annually to the NCSP Manager (AM3: Q2)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Activation and Thermoluminescent Detector Responses to a Bare Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 11, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

Miller, Thomas Martin↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Lead Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 13, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube, and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc, depositing energy in a Si solid-state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Activation Foil and Thermoluminescent Dosimeter Responses to a Polyethylene Reflected Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 19, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. The CIDAS detects gammas with a Geiger-Muller tube and the Rocky Flats detects neutrons via charged particles produced in a thin 6 LiF disc depositing energy in a Si solid state detector. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis Capability and Data Needs Identified During the Evaluation of the SILENE CAAS Benchmarks

In October 2010, a series of benchmark experiments was conducted at the Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA to create three benchmarks for verification and validation of radiation transport codes, as well as evaluated nuclear data, used to analyze criticality accident alarm systems (CAASs). Many preliminary details of these experiments and their evaluation have been discussed in previous publications. The first benchmark evaluation was published in 2015, and the second and third evaluations will be published at the end of 2016. During evaluation of the three benchmarks, differences were observed between the measured and calculated benchmark values, which was not surprising. Evaluators spent a great deal of time identifying the sources of these differences. This paper presents two of the most important and clearly identifiable differences, which the authors identify as needs for the criticality safety and shielding communities. The first need is the capability to easily produce and transport delayed neutrons and gammas within existing radiation transport codes without coupling to a separate decay and depletion code. The second need is to fill in missing gamma production data in the evaluated nuclear data libraries. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis Capability and Data Needs Identified During the Evaluation of the SILENE CAAS Benchmarks

In October 2010, a series of benchmark experiments was conducted at the Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA to create three benchmarks for verification and validation of radiation transport codes, as well as evaluated nuclear data, used to analyze criticality accident alarm systems (CAASs). Many preliminary details of these experiments and their evaluation have been discussed in previous publications. The first benchmark evaluation was published in 2015, and the second and third evaluations will be published at the end of 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creation of problem-dependent Doppler-broadened cross sections in the KENO Monte Carlo code

In this paper, we introduce a quick method for improving the accuracy of Monte Carlo simulations by generating one- and two-dimensional cross sections at a user-defined temperature before performing transport calculations. A finite difference method is used to Doppler-broaden cross sections to the desired temperature, and unit-base interpolation is done to generate the probability distributions for double differential two-dimensional thermal moderator cross sections at any arbitrarily user-defined temperature. The accuracy of these methods is tested using a variety of contrived problems. In addition, various benchmarks at elevated temperatures are modeled, and results are compared with benchmark results. Lastly, the problem-dependent cross sections are observed to produce eigenvalue estimates that are closer to the benchmark results than those without the problem-dependent cross sections.

42 ENGINEERING↗

Criticality safety enhancements for SCALE 6.2 and beyond

SCALE is a widely used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. Since 1980, regulators, industry, and research institutions around the world have relied on SCALE for nuclear safety analysis and design. SCALE 6.2 provides several new capabilities and significant improvements in many existing features for criticality safety analysis. Enhancements are realized for nuclear data; multigroup resonance self-shielding; continuous-energy Monte Carlo analysis for sensitivity/uncertainty analysis, radiation shielding, and depletion; and graphical user interfaces. An overview of these capabilities is provided in this paper, and additional details are provided in several companion papers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of the concrete shield compositions from the 2010 criticality accident alarm system benchmark experiments at the CEA Valduc SILENE facility

In October 2010, a series of benchmark experiments were conducted at the French Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the United States Department of Energy Nuclear Criticality Safety Program and the CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems. This series of experiments consisted of three single-pulsed experiments with the SILENE reactor. For the first experiment, the reactor was bare (unshielded), whereas in the second and third experiments, it was shielded by lead and polyethylene, respectively. The polyethylene shield of the third experiment had a cadmium liner on its internal and external surfaces, which vertically was located near the fuel region of SILENE. During each experiment, several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor. Nearly half of the foils and TLDs had additional high-density magnetite concrete, high-density barite concrete, standard concrete, and/or BoroBond shields. CEA Saclay provided all the concrete, and the US Y-12 National Security Complex provided the BoroBond. Measurement data from the experiments were published at the 2011 International Conference on Nuclear Criticality (ICNC 2011) and the 2013 Nuclear Criticality Safety Division (NCSD 2013) topical meeting. Preliminary computational results for the first experiment were presented in the ICNC 2011 paper, which showed poor agreement between the computational results and the measured values of the foils shielded by concrete. Recently the hydrogen content, boron content, and density of these concrete shields were further investigated within the constraints of the previously available data. New computational results for the first experiment are now available that show much better agreement with the measured values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗