Search NASA⌕ Search

Engineering topics

Chalenski, D A

Publications and source records attributed to Chalenski, D A.

Azimuthally correlated ablation between z-pinch wire cores

Azimuthally correlated wire core ablation was compared for closely spaced versus widely spaced wires in a 1 MA Z-pinch. X-ray point-projection diagnostics revealed that 240 {mu}m spaced wires exhibited a correlation coefficient approaching unity in both real space and in k-space. This correlated ablation between wires at a fixed axial location is believed to occur due to an enhanced, localized Joule heating. Wires separated by 2.47 mm or greater were uncorrelated in real space, but correlated in k-space, indicating the ablation structure between wires was shifted in phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of Multi-Planar and Compact Cylindrical Wire Arrays Implosions on University-Scale Z-pinch Generators

The presented research focuses on investigation of Z-pinch plasma formation, implosion, and radiation characteristics as a function of the load configuration. The single planar and multi-planar wire arrays as well as compact cylindrical wire arrays were studied on the 1.3 MA UNR Zebra and 1 MA Cornell COBRA generators. The largest yields and powers were found for W and Mo double planar and compact wire arrays. A possibility of radiation pulse shaping was demonstrated. Two types of bright spots were observed in plasmas. A comparison of Mo double planar and compact wire array data indicates the possibility that the same heating mechanism operates during the final implosion and stagnation stages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soldered Contact and Current Risetime Effects on Negative Polarity Wire Array Z-pinches

The Cornell University COBRA pulser is a nominal 1 MA machine, capable of driving up to 32 wire cylindrical Z-pinch arrays. COBRA can operate with variable current risetimes ranging from 100 ns to 200 ns (short and long pulse, respectively). Wires are typically strung with a 'press' contact to the electrode hardware, where the wire is loosely pulled against the hardware and held there to establish electrical contact. The machine is normally negative, but a bolt-on convolute can be used to modify the current path and effectively produce positive polarity operation at the load.Previous research with single wires on a 1-5 kA pulser has shown that soldering the wire, thereby improving the wire/electrode contact, and operating in positive polarity can improve the energy deposition into the wire and enhance wire core expansion. Negative polarity showed no difference. Previous experiments on the negative polarity, 20 MA, 100 ns Z accelerator have shown that improving the contact improved the x-ray yield.Cornell data were collected on 16-wire Aluminum Z-pinch arrays in negative polarity. Experiments were conducted with both short and long current pulses with soldered and no-soldered wire/electrode contacts. The initiation, ablation, implosion and stagnation phases were compared for these four conditions. Time dependent x-ray signals were measured using diodes and diamond detectors. An inductive voltage monitor was used to infer minimum current radius achieved, as defined by a uniform shell of current moving radially inward, producing a time dependent inductance. Total energy data were collected with a metal-strip bolometer. Self-emission data were collected by an XUV 4-frame camera and an optical streak camera.In negative polarity and with short pulses, soldering appeared to produce a smaller radius pinch and decrease variations in the x-ray pulse shape. The bolometer, laser backlighter, 4-frame and streak cameras showed negligible differences in the initiation ablation and implosion phases. X-ray yield was increased with soldered arrays in negative polarity with long pulses. The bolometer also showed a 50% increase in radial power emitted for soldered arrays. 4-frame images showed soldered arrays have a more pronounced 'Christmas Tree' effect originating from the cathode. The inductive voltage monitor showed, with both long and short pulses, that soldered and no-solder arrays reached the same minimum current radius at the same time. However, with long pulses soldered arrays radiate x-rays at the time of minimum current radius while no-solder array x-ray output is delayed by {approx}20 ns, resulting in decreased x-ray yield.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of the Axial Instability in Low Wire Number Wire Array Z-Pinches

We are investigating the development of the axial instability, a modulation of the size of the coronal plasma that develops around each wire in wire-array Z-pinches. The modulation is a result of nonuniform ablation of material from the relatively cold wire core. It has long been known that the wavelength of this modulation is constant late in time and, since it is unique to different materials, it has come to be known as the fundamental mode. In these experiments we imaged individual wires with laser shadowgraphy early in time primarily in low wire number, large wire diameter aluminum arrays for ease of viewing. We Observe the development of this modulation from the time of initiation of coronal plasma, obtaining its dominant wavelength and amplitude growth as a function of time. We also studied the instability on coiled wires, which modify the wire ablation mechanism and completely suppress the fundamental mode[Hall2008]. time is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ablation dominated implosion dynamics of aluminum and stainless steel nested cylindrical wire arrays

The results of experiments with combined aluminum (Al) and stainless steel (SS) alloy 304, nested wire arrays from the 1 MA COBRA generator at Cornell University are presented. The loads studied consisted of a 6 mm diameter inner array and a 13 mm diameter outer array with a different material in each array: SS or aluminum. Al implodes before SS in all loads studied, even when Al was on the inner array. The new wire ablation dynamic model and spectroscopic modeling are used to interpret these data. The observed implosion dynamics are likely a result of the higher ablation rate of Al. These initial results suggest that combining wire materials with different ablation rates in wire array loads could be developed into a useful technique for x-ray pulse shaping and radiation yield optimization.

36 MATERIALS SCIENCE↗

Implosion dynamics and radiation characteristics of wire-array Z pinches on the Cornell Beam Research Accelerator

Experimental results are presented that characterize the implosion dynamics and radiation output of wire-array Z pinches on the 1-MA, 100-ns rise-time Cornell Beam Research Accelerator (COBRA) [J. B. Greenly et al., Rev. Sci. Instrum. 79, 073501 (2008)]. The load geometries investigated include 20-mm-tall cylindrical arrays ranging from 4 to 16 mm in diameter, and consisting of 8, 16, or 32 wires of either tungsten, aluminum, or Invar (64% iron, 36% nickel). Diagnostics fielded include an optical streak camera, a time-gated extreme-ultraviolet framing camera, a laser shadowgraph system, time-integrated pinhole cameras, an x-ray wide-band focusing spectrograph with spatial resolution, an x-ray streak camera, a load voltage monitor, a Faraday cup, a bolometer, silicon diodes, and diamond photoconducting detectors. The data produced by the entire suite of diagnostics are analyzed and presented to provide a detailed picture of the overall implosion process and resulting radiation output on COBRA. The highest x-ray peak powers (300-500 GW) and total energy yields (6-10 kJ) were obtained using 4-mm-diameter arrays that stagnated before peak current. Additional findings include a decrease in soft x-ray radiation prior to stagnation as the initial wire spacing was changed from 1.6 mm to 785 {mu}m, and a timing correlation between the onset of energetic electrons, hard x-ray generation, and the arrival of trailing current on axis - a correlation that is likely due to the formation of micropinches. The details of these and other findings are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗