Search NASA⌕ Search

Engineering topics

Champley, Kyle M.

Publications and source records attributed to Champley, Kyle M..

Fused x-ray and fast neutron CT reconstruction for imaging large and dense objects

Megavolt x-ray computed tomography (CT) is a powerful tool for three-dimensional characterization. However, its utility is limited for large objects composed of high-atomic number (Z) materials, where x rays fail to penetrate. Information from fast neutron CT (FNCT) can complement x-ray CT reconstructions since fast neutrons can more readily penetrate high-Z objects. In this work, we demonstrate a method for combining FNCT and x-ray CT data to create a single reconstruction, more accurate than could be achieved with either x rays or fast neutrons alone. The algorithm was tested on an exemplar comprising multiple concentric, nested cylinders of different materials. Simulated and empirical x-ray CT data were acquired for the exemplar using a 9 MV bremsstrahlung spectrum. Additional simulated and empirical FNCT data were acquired using an accelerator based fast neutron source. The FNCT data were used to synthesize x-ray CT data and augment the x-ray CT data missing due to lack of penetration. This approach mitigates artifacts that would otherwise negatively affect the accuracy and resolution of a single-modality reconstructed volume.

47 OTHER INSTRUMENTATION↗

Dual-energy fast neutron imaging using tunable short-pulse laser-driven sources

Here a novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Object-space optimization of tomographic reconstructions for additive manufacturing

Volumetric 3D printing motivated by computed axial lithography enables rapid printing of homogeneous parts but requires a high dimensionality gradient-descent optimization to calculate image sets. Here we introduce a new, simpler approach to image-computation that algebraically optimizes a model of the printed object, significantly improving print accuracy of complex parts under imperfect material and optical precision by improving optical dose contrast between the target and surrounding regions. Quality metrics for volumetric printing are defined and shown to be significantly improved by the new algorithm. The approach is extended beyond binary printing to grayscale control of conversion to enable functionally graded materials. The flexibility of the technique is digitally demonstrated with realistic projector point spread functions, printing around occluding structures, printing with restricted angular range, and incorporation of materials chemistry such as inhibition. Finally, simulations show that the method facilitates new printing modalities such as printing into flat, rather than cylindrical packages to extend the applications of volumetric printing.

36 MATERIALS SCIENCE↗