Search NASA⌕ Search

Engineering topics

Chavarria, A.

Publications and source records attributed to Chavarria, A..

New Technologies for Discovery

For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Status of the dark matter experiment DarkSide-50

DarkSide-50 is a dark matter direct search experiment at LNGS, searching for rare nuclear recoils possibly induced by WIMPs. It has two nested vetoes and a dual phase liquid argon TPC as dark matter detector. Key features of this experiment are the use of underground argon as radio-pure target and of muon and neutron active vetoes to suppress the background. The first data-taking campaign was running from November 2013 to April 2015 with an atmospheric argon target and a reduced efficiency neutron veto due to internal contamination. However, an upper limit on the WIMP-nucleon cross section of 6.1×10 -44 cm 2 at 90% CL was obtained for a WIMP mass of 100 GeV/c 2 and an exposure of (1422 ± 67) kg·d. At present DarkSide-50 started a 3 years run, intended to be background-free because the neutron veto was successfully recovered and underground argon replaced the atmospheric one. Additionally calibration campaigns for both the TPC and the neutron veto were completed. Thanks to the good performance of the background rejection, the results obtained so far suggest the scalability of DarkSide-50 to a ton-scale detector, which will play a key role into the dark matter search scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A first walk on the DarkSide

DarkSide-50 (DS-50) at Gran Sasso underground laboratory (LNGS), Italy, is a direct dark matter search experiment based on a TPC with liquid argon. DS-50 has completed its first dark matter run using atmospheric argon as target. Here, the DS-50 detector performances and the results of the first physics run are reviewed in this proceeding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light yield in DarkSide-10: A prototype two-phase argon TPC for dark matter searches

As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SOX: Short distance neutrino Oscillations with BoreXino

The very low radioactive background of the Borexino detector, its large size, and the well proved capability to detect both low energy neutrino and anti-neutrino make an ideal case for the study of short distance neutrino oscillations with artificial sources at Gran Sasso. This paper describes the possible layouts of 51 Cr neutrino and 144 Ce- 144 Pr anti-neutrino source experiments in Borexino and shows the expected sensitivity for three possible different phases of the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmogenic Backgrounds in Borexino at 3800 m water-equivalent depth

The solar neutrino experiment Borexino, which is located in the Gran Sasso underground laboratories, is in a unique position to study muon-induced backgrounds in an organic liquid scintillator. In this study, a large sample of cosmic muons is identified and tracked by a muon veto detector external to the liquid scintillator, and by the specific light patterns observed when muons cross the scintillator volume. The yield of muon-induced neutrons is found to be Y{sub n} = (3.10±0.11)·10{sup −4} n/(μ·(g/cm{sup 2})). The distance profile between the parent muon track and the neutron capture point has the average value λ = (81.5±2.7) cm. Additionally the yields of a number of cosmogenic radioisotopes are measured for {sup 12}N, {sup 12}B, {sup 8}He, {sup 9}C, {sup 9}Li, {sup 8}B, {sup 6}He, {sup 8}Li, {sup 11}Be, {sup 10}C and {sup 11}C. All results are compared with Monte Carlo simulation predictions using the FLUKA and GEANT4 packages. General agreement between data and simulation is observed for the cosmogenic production yields with a few exceptions, the most prominent case being {sup 11}C yield for which both codes return about 50% lower values. The predicted μ-n distance profile and the neutron multiplicity distribution are found to be overall consistent with data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS

We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) \mu s and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties and are compatible with previous measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗