Object detectability at increased ambient lighting conditions

Under typical dark conditions encountered in diagnostic reading rooms, a reader's pupils will contract and dilate as the visual focus intermittently shifts between the high luminance display and the darker background wall, resulting in increased visual fatigue and the degradation of diagnostic performance. A controlled increase of ambient lighting may, however, reduce the severity of these pupillary adjustments by minimizing the difference between the luminance level to which the eyes adapt while viewing an image (L{sub adp}) and the luminance level of diffusely reflected light from the area surrounding the display (L{sub s}). Although ambient lighting in reading rooms has conventionally been kept at a minimum to maintain the perceived contrast of film images, proper Digital Imaging and Communications in Medicine (DICOM) calibration of modern medical-grade liquid crystal displays can compensate for minor lighting increases with very little loss of image contrast. This paper describes two psychophysical studies developed to evaluate and refine optimum reading room ambient lighting conditions through the use of observational tasks intended to simulate real clinical practices. The first study utilized the biologic contrast response of the human visual system to determine a range of representative L{sub adp} values for typical medical images. Readers identified low contrast horizontal objects in circular foregrounds of uniform luminance (5, 12, 20, and 30 cd/m{sup 2}) embedded within digitized mammograms. The second study examined the effect of increased ambient lighting on the detection of subtle objects embedded in circular foregrounds of uniform luminance (5, 12, and 35 cd/m{sup 2}) centered within a constant background of 12 cd/m{sup 2} luminance. The images were displayed under a dark room condition (1 lux) and an increased ambient lighting level (50 lux) such that the luminance level of the diffusely reflected light from the background wall was approximately equal to the image L{sub adp} value of 12 cd/m{sup 2}. Results from the first study demonstrated that observer true positive and false positive detection rates and true positive detection times were considerably better while viewing foregrounds at 12 and 20 cd/m{sup 2} than at the other foreground luminance levels. Results from the second study revealed that under increased room illuminance, the average true positive detection rate improved a statistically significant amount from 39.3% to 55.6% at 5 cd/m{sup 2} foreground luminance. Additionally, the true positive rate increased from 46.4% to 56.6% at 35 cd/m{sup 2} foreground luminance, and decreased slightly from 90.2% to 87.5% at 12 cd/m{sup 2} foreground luminance. False positive rates at all foreground luminance levels remained approximately constant with increased ambient lighting. Furthermore, under increased room illuminance, true positive detection times declined at every foreground luminance level, with the most considerable decrease (approximately 500 ms) at the 5 cd/m{sup 2} foreground luminance. The first study suggests that L{sub adp} of typical mammograms lies between 12 and 20 cd/m{sup 2}, leading to an optimum reading room illuminance of approximately 50-80 lux. Findings from the second study provide psychophysical evidence that ambient lighting may be increased to a level within this range, potentially improving radiologist comfort, without deleterious effects on diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A mathematical model platform for optimizing a multiprojection breast imaging system

Multiprojection imaging is a technique in which a plurality of digital radiographic images of the same patient are acquired within a short interval of time from slightly different angles. Information from each image is combined to determine the final diagnosis. Projection data are either reconstructed into slices as in the case of tomosynthesis or analyzed directly as in the case of multiprojection correlation imaging technique, thereby avoiding reconstruction artifacts. In this study, the authors investigated the optimum geometry of acquisitions of a multiprojection breast correlation imaging system in terms of the number of projections and their total angular span that yield maximum performance in a task that models clinical decision. Twenty-five angular projections of each breast from 82 human subjects in our breast tomosynthesis database were each supplemented with a simulated 3 mm mass. An approach based on Laguerre-Gauss channelized Hotelling observer was developed to assess the detectability of the mass in terms of receiver operating characteristic (ROC) curves. Two methodologies were developed to integrate results from individual projections into one combined ROC curve as the overall figure of merit. To optimize the acquisition geometry, different components of acquisitions were changed to investigate which one of the many possible configurations maximized the area under the combined ROC curve. Optimization was investigated under two acquisition dose conditions corresponding to a fixed total dose delivered to the patient and a variable dose condition, based on the number of projections used. In either case, the detectability was dependent on the number of projections used, the total angular span of those projections, and the acquisition dose level. In the first case, the detectability approximately followed a bell curve as a function of the number of projections with the maximum between 8 and 16 projections spanning angular arcs of about 23 deg. - 45 deg., respectively. In the second case, the detectability increased with the number of projections approaching an asymptote at 11-17 projections for an angular span of about 45 deg. These results indicate the inherent information content of the multiprojection image data reflecting the relative role of quantum and anatomical noise in multiprojection breast imaging. The optimization scheme presented here may be applied to any multiprojection imaging modalities and may be extended by including reconstruction in the case of digital breast tomosynthesis and breast computed tomography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗