Irradiation of 20L LEU Uranyl Sulfate Solution for Production of Mo-99

Argonne National Laboratory, with support from the National Nuclear Security Administration’s Office of Material Management and Minimization, is assisting SHINE Medical Technologies in the development of accelerator-driven production of 99 Mo using low-enriched uranium (LEU). Technetium-99m ( 99m Tc), a daughter of 99 Mo, is a workhorse of nuclear medicine, used in approximately 40,000 medical testing procedures each day just in the U.S.

07 ISOTOPE AND RADIATION SOURCES↗

Design of the Universal Neutron Irradiator

SHINE medical isotopes is developing a novel method to produce the medical isotope Mo-99, which is the parent of Tc-99m, the most widely used diagnostic compound in nuclear medicine. This method utilizes U-235 fission in a subcritical liquid target solution, driven by an accelerator-based neutron source that is based on a deuterium-tritium reaction in a gaseous target. In this approach, the neutron-generating target is surrounded by uranyl sulfate (low-enriched uranium); fission in the uranium salt solution efficiently produces the desired Mo-99, as well as other fission products. After irradiation, Mo-99 is separated and the uranyl sulfate solution can be irradiated again to produce Mo-99. This allows the solution to be recycled for a very long time and significantly reduces the amount of associated nuclear waste. SHINE has received U.S. Nuclear Regulatory Commission (NRC) approval to construct an Mo-99 production facility based on this method. In order to produce Mo-99 efficiently, the solution should be as close as possible to criticality. Because the solution is over moderated, any precipitation could push the solution to become critical and thereby hard to control. One of the possible precipitation scenarios is the formation of uranyl peroxide. Under irradiation, water decomposes into the products of radiolysis, some of which will form peroxide. To prevent precipitation, one has to develop a way to decompose the peroxide before it can react with uranium and form hard-to-dissolve precipitates. To study peroxide formation and develop methods to prevent precipitation, we are developing an experiment capable of mimicking radiation conditions in the SHINE system. This report describes the irradiation setup we designed to irradiate a small volume of uranyl sulfate solution for the duration of one SHINE irradiation (~6 days) at the relevant fission power (~0.5 W/cc)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of the NorthStar Inconel 718 Window

NorthStar Medical Radioisotopes, LLC, is planning to produce the important medical radioisotope molybdenum-99 (Mo-99) through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling of the target. In the latest concept developed by NorthStar, a stack of target (sintered molybdenum) disks is irradiated from two sides by a 40-MeV electron beam, with a total power of 240 kW (120 kW from each side). As shown in Figure 1, the target disks are cooled by pressurized helium gas flowing through channels between the disks. A housing encloses the target disks and helium coolant. Thinned regions on opposite sides of the housing act as windows, forming the pressure boundary between the helium within the housing and the evacuated beam tube. A pulsed (50-Hz) 40-MeV electron beam is used, with 120 kW total power and a 10% duty cycle. The pulsing beam creates a corresponding cyclic thermal load within the window material. To examine the effects of the cyclic thermal load on the window, a combination of analyses was performed, including computational fluid dynamics (CFD) and finite element analysis (FEA). The analyses presented in this report were primarily performed using the finite element method. However, because of the curved surface of the window, CFD analysis was used to calculate the convective cooling boundary included in the FEA model. Transient thermal and structural models were used to explore the window geometry, including thickness, radius of curvature, and diameter, while staying within the temperature and stress limits of the material as well as maintaining mechanical stability (i.e., avoiding buckling). Additionally, variations in the size and location of the electron beam were evaluated. Multiple parameters for the window and the electron beam were examined throughout the analysis. Upper and lower bounds were established for the window geometry parameters, and limitations were established for the size and position of the electron beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production of Medical Isotopes with Electron Linacs

Radioisotopes play important roles in numerous areas ranging from medical treatments to national security and basic research. Radionuclide production technology for medical applications has been pursued since the early 1900s both commercially and in nuclear science centers. Many medical isotopes are now in routine production and are used in day-to-day medical procedures. Despite these advancements, research is accelerating around the world to improve the existing production methodologies as well as to develop novel radionuclides for new medical appli-cations. Electron linear accelerators (linacs) represent a unique method for the production of radioisotopes. Even though the basic technology has been around for decades, only recently have electron linacs capable of producing photons with sufficient energy and flux for radioisotope production become available. Housed in Argonne Nation-al Laboratory’s Low Energy Accelerator Facility (LEAF) is a newly upgraded 55 MeV/25-kW electron linear ac-celerator, capable of producing a wide range of radioiso-topes. This talk will focus on the work being performed for the production of the medical isotopes 99Mo (99Mo/99mTc generator), 67Cu, and 47Sc.

Cu-67↗

Accelerator-Driven Production of Fission 99Mo

I{esults al'e reportecl for the procluction of eeMo l'rom the accelerator-clriveu subcritical fission of a low enriohed uranir¡m (Ltju) aqì.reous solution. Phase I ol'these experiments used a 5 L r.rranyl sulfate solution with a eeMo encl-of-irracliation produotion limit of 2 Ci. The separation, recovery, and pulification of eeMo were demonstrated Lrsing the recyclecl solution. Fission product paltitioriing tl'ends will be shown for the recovery colutt'ttt, concentratiorl colurnn, and LE,U Modified Cintichem prooess. The results fi'om a 1.4 Ci oeMo production run, where the fìnal product was seut to GE Flealthcare for testing, will be highlightecl. The information gained cluring Phase ì lias signilìcantly irnpacted the clesign and implernentation of Phase ll. Phase II focuses on an end-of-irradiation ploduction of 20 Ci of eeMo and a fissior'ì power density similar to the production fàcility in a20 L LìlU uranyl sulfate solution.

accelerator↗

Micro-Bubble Experiments at the Van de Graaff Accelerator

In order to test and verify the experimental designs at the linear accelerator (LINAC), several micro-scale bubble ("micro-bubble") experiments were conducted with the 3-MeV Van de Graaff (VDG) electron accelerator. The experimental setups included a square quartz tube, sodium bisulfate solution with different concentrations, cooling coils, gas chromatography (GC) system, raster magnets, and two high-resolution cameras that were controlled by a LabVIEW program. Different beam currents were applied in the VDG irradiation. Bubble generation (radiolysis), thermal expansion, thermal convection, and radiation damage were observed in the experiments. Photographs, videos, and gas formation (O 2 + H 2 ) data were collected. The micro-bubble experiments at VDG indicate that the design of the full-scale bubble experiments at the LINAC is reasonable.