DBD plasma-assisted ethanol steam reforming for green H 2 production: Process optimization through response surface methodology (RSM)

Herein this work investigates ethanol steam reforming (ESR) to produce hydrogen (H 2 ) in a dielectric barrier discharge (DBD) plasma reactor. A five-level, three-factor experiment design was performed using a response surface methodology (RSM) to evaluate the combined effects of the three process parameters, including discharge power, total flow rate, and ethanol-to-water (EtOH/H 2 O) molar ratio on the plasma-assisted ESR reaction. Quadratic regression models were employed in RSM to fit the experimental results and present the correlation between process parameters and targeted responses (EtOH conversion, H 2 yield, H 2 selectivity, and specific energy requirement (SER) for H 2 production). The results suggested that the EtOH/H 2 O molar ratio is considered to have the most significant effect on the EtOH conversion and H 2 , H 2 selectivity, while the total flow rate is the most significant parameter determining SER for H 2 production. Process optimization demonstrated the optimal process conditions, including a discharge power of 55.9 W, a total flow rate of 26.7 ml/min, and an EtOH/H 2 O molar ratio equal to 0.34. A validation test was performed and confirmed the feasibility of the optimization process.

08 HYDROGEN↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

CO 2 conversion to syngas via electrification of endothermal reactors: Process design and environmental impact analysis

CO 2 utilization via reverse water gas shift (rWGS) reaction has been proposed as a path to the sustainable utilization. Here this work presents a detailed process modelling study where steam methane reforming (SMR) generated hydrogen was combined with rWGS to produce syngas (CO + H 2 ) with various hydrogen-to-carbon oxide ratios. To further decrease CO 2 emissions that may offset the benefits of CO 2 converted in rWGS, electrification of endothermal reactors, both SMR and rWGS was considered where CO 2 emitting fuel burning in the furnace was replaced by the emerging ohmic (resistive) heating. Material and energy inventory obtained from process design calculations was used to perform Life Cycle Analysis (LCA) to calculate environmental impacts of CO 2 consumption and reactor electrification. The results showed that greenhouse gas emissions, in CO 2 kg equivalent, were the lowest when both SMR and rWGS were heated using wind-generated electricity, decreasing from 25 to 10 kg CO 2 equivalent for H 2 :CO = 2:1 while the conventional electricity mix used for furnace electrical heating across the board of scenarios generated highest environmental impacts, much higher than those that used natural gas as fuel. Process economics calculations suggested that, when both SMR and rWGS were electrically heated, the process only showed product syngas cost parity with the conventional fuel heated design when electricity cost was ~$0.008/kWh. This suggests that CO 2 utilization scenarios involving process electrification need to be carefully considered from the total design perspective so they do not produce more greenhouse gases than in conventional non-electrified scenarios.

42 ENGINEERING↗

DEMONSTRATION OF A PASSIVE CONDENSER LOOP

Building HVAC consumes significant amount of energy. It is estimated that about 7% of the total electricity consumed by water cooled chiller is used to drive the condenser water pump. A passive condenser loop is developed to curb this energy consumption by replacing the open pumped loop to a closed loop thermosyphon system. The loop thermosyphon uses waste heat to circulate the condenser fluid, eliminating the electrical pumping power requirement and the large circulation pump. Since it is a closed loop, it also reduces the maintenance cost and enables both wet and dry cooling modes. A demonstration unit with a riser about 40 feet (12.2 meters) tall is fabricated and tested at powers up to 25 kW. The result has successfully showed that the loop thermosyphon is able to transfer the heat near isothermally (∆T < 0.4C) over the long distance without the need of any pump and consuming any electricity.

Loop thermosyphon, building HVAC, condenser loop↗

Incineration system and process

An incineration system includes an inlet channel supplying an inlet stream comprising a waste gas containing at least one volatile organic compound, a waste gas sensor measuring at least one property of the waste gas, an oxidizing gas supply controllably providing oxidizing gas to the inlet channel, an incinerator receiving the inlet stream from the inlet channel, an ignitor initiating combustion of the inlet stream in the reaction zone of the incinerator, and a controller receiving data from the waste gas sensor and controlling flow of oxidizing gas from the oxidizing gas supply into the inlet channel. The spiral heat exchanger defines a reaction zone, an incoming path from the inlet channels to the reaction zone, and an outgoing path from the reaction zone to an exhaust channel. The incoming path and the outgoing path extend in alternating concentric spirals with the incoming path being countercurrent to the outgoing path.

42 ENGINEERING↗

Bio-inspired self-agitator for convective heat transfer enhancement

Convective heat transfer plays an important role in both the fundamental research and the development of high-performance heat exchangers. Inspired by blades of grass vibrating in the wind, we developed a self-agitator for convective heat transfer enhancement. Because of fluid-structure interactions, the agitator, with self-sustained vibration, can generate strong vortices to significantly break the thermal boundary layer and improve fluid mixing for enhanced convective heat transfer. In particular, we establish a methodology to link the vorticity field at a preferred frequency to the optimal improvement in the convective heat transfer. To identify the self-agitator preferred frequency, mode analysis is performed with simulation results using dynamic mode decomposition. Experimental results are also obtained to further validate the proposed approach. These results show that the proposed self-agitator design can improve the convective heat transfer by 120% in a conventional heat exchanger without additional pumping power requirements and can achieve a Nusselt number of up to 30 within the laminar flow region, which is improved by 200% with the same Reynolds number compared to the clean channel.

Li, Zheng↗