Search NASA⌕ Search

Engineering topics

Chen, Chin-Tu

Publications and source records attributed to Chen, Chin-Tu.

Efficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac) 2 ], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 ( 48 V) generated with a compact medical cyclotron has been used to label VO(acac) 2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac) 2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac) 2 , [ 48 V]VO(acac) 2 , and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [ 48 V]VO(acac) 2 . Preliminary results of preclinical, small-animal PET studies are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simplified protocol for the automated production of 2‐[ 18 F]fluoro‐3‐[2‐((S)‐3‐pyrrolinyl)methoxy]pyridine ([ 18 F]nifene) on an IBA Synthera® module

The α4β2 nicotinic acetylcholine receptor (nAChR) ligand 2‐[18F]fluoro‐3‐[2‐((S)‐3‐pyrrolinyl)methoxy]pyridine ([18F]nifene) has been synthesized in 10% decay‐corrected radiochemical yield using the IBA Synthera® platform (IBA Cyclotron Solutions, Louvain‐la‐Neuve, Belgium) with an integrated fluidic processor (IFP). Boc‐nitronifene served as the precursor, and 20% trifluoroacetic acid (TFA) was used to deprotect the Boc‐group after radiolabeling. By omitting the solvent extraction step after radiolabeling, the process was simplified to a single step with no manual intervention. [18F]Nifene was obtained in decay‐corrected radiochemical yields of 10 ± 2% (n = 20) and radiochemical purity >99%. Typical specific radioactivities of 2700–4865 mCi/μmole (100–180 GBq/μmol) were measured at the end of synthesis; total synthesis times were about 1 h 40 min.

IBA Synthera®↗

Evaluation of an Image-Derived Input Function for Kinetic Modeling of Nicotinic Acetylcholine Receptor-Binding PET Ligands in Mice

Positron emission tomography (PET) radioligands that bind with high-affinity to α4β2-type nicotinic receptors (α4β2Rs) allow for in vivo investigations of the mechanisms underlying nicotine addiction and smoking cessation. Here, we investigate the use of an image-derived arterial input function and the cerebellum for kinetic analysis of radioligand binding in mice. Two radioligands were explored: 2-[ 18 F]FA85380 (2-FA), displaying similar pKa and binding affinity to the smoking cessation drug varenicline (Chantix), and [ 18 F]Nifene, displaying similar pKa and binding affinity to nicotine. Time–activity curves of the left ventricle of the heart displayed similar distribution across wild type mice, mice lacking the β2-subunit for ligand binding, and acute nicotine-treated mice, whereas reference tissue binding displayed high variation between groups. Binding potential estimated from a two-tissue compartment model fit of the data with the image-derived input function were higher than estimates from reference tissue-based estimations. Rate constants of radioligand dissociation were very slow for 2-FA and very fast for Nifene. We conclude that using an image-derived input function for kinetic modeling of nicotinic PET ligands provides suitable results compared to reference tissue-based methods and that the chemical properties of 2-FA and Nifene are suitable to study receptor response to nicotine addiction and smoking cessation therapies.

2-FA85380↗

Accelerator-Based Production of Scandium Radioisotopes for Applications in Prostate Cancer: Toward Building a Pipeline for Rapid Development of Novel Theranostics

In the field of nuclear medicine, the β + -emitting 43 Sc and β - -emitting 47 Sc are promising candidates in cancer diagnosis and targeted radionuclide therapy (TRT) due to their favorable decay schema and shared pharmacokinetics as a true theranostic pair. Additionally, scandium is a group-3 transition metal (like 177 Lu) and exhibits affinity for DOTA-based chelators, which have been studied in depth, making the barrier to implementation lower for 43/47 Sc than for other proposed true theranostics. Before 43/47 Sc can see widespread pre-clinical evaluation, however, an accessible production methodology must be established and each isotope’s radiolabeling and animal imaging capabilities studied with a widely utilized tracer. As such, a simple means of converting an 18 MeV biomedical cyclotron to support solid targets and produce 43 Sc via the 42 Ca(d,n) 43 Sc reaction has been devised, exhibiting reasonable yields. The Nat Ti(γ,p) 47 Sc reaction is also investigated along with the successful implementation of chemical separation and purification methods for 43/47 Sc. The conjugation of 43/47 Sc with PSMA-617 at specific activities of up to 8.94 MBq/nmol and the subsequent imaging of LNCaP-ENZaR tumor xenografts in mouse models with both 43/47 Sc-PSMA-617 are also presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary investigation of 48 V-labeled VO(acac) 2 for cancer imaging: An initial proof-of-concept study

In this preliminary study, a procedure for synthesizing novel PET radiotracer vanadium-48-labeled-vanadyl acetylacetonate was developed, including radioisotope production via cyclotron, separation of 48 V, chelation as 48 VO(acac) 2 , and assessment through in vitro cellular studies. We employed the beam-stop setup in a cyclotron as the target holder to irradiate titanium foils in the reaction of nat Ti (p,n) 48 V. The radioisotope production rate was 4.84 ± 0.67 μCi/μA-h. Overall radiochemical yield was 12.86 ± 0.51% with gamma-ray spectroscopy showing no detectable contaminant peaks. HPLC of 48 VO(acac) 2 showed a retention time (1:48) corresponding closely to that (1:50) of commercial VO(acac) 2 , verifying the successful synthesis of 8VO(acac) 2 . In vitro cellular studies demonstrated radiotracer uptake and saturation around 0.48 nM. These studies pave the way for improving methodologies and in vivo experiments, including imaging studies, in future investigations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic and Programmable Cellular-Scale Granules Enable Tissue-like Materials

Living tissues are an integrated, multiscale architecture consisting of dense cellular ensembles and extracellular matrices (ECMs). The cells and ECMs cooperate to enable specialized mechanical properties and dynamic responsiveness. However, the mechanical properties of living tissues are difficult to replicate. A particular challenge is identification of a cell-like synthetic component, which is tightly integrated with its matrix and also responsive to external stimuli. Here, we demonstrate that cellular-scale hydrated starch granules, an underexplored component in materials science, can turn conventional hydrogels into tissue-like materials when composites are formed. By using several synchrotron-based X-ray techniques, we reveal the mechanically induced organization and training dynamics of the starch granules in the hydrogel matrix. These dynamic behaviors enable multiple tissue-like properties such as programmability, anisotropy, strain-stiffening, mechanochemistry, and self-healability.

36 MATERIALS SCIENCE↗

Radioluminescence characterization of in situ x-ray nanodosimeters: Potential real-time monitors and modulators of external beam radiation therapy

Europium-doped yttrium oxide (Y{sub 2}O{sub 3}:Eu) has garnered considerable interest recently for its use as a highly efficient, red phosphor in a variety of lighting applications that include fluorescent lamps, plasma, and field emission display panels, light emitting diodes (LEDs), and lasers. In the present work, we describe the development of Y{sub 2}O{sub 3}:Eu nanoparticles for a very different application: in situ, in vivo x-ray dosimetry. Spectroscopic analyses of these nanoparticles during x-ray irradiation reveal surprisingly bright and stable radioluminescence at near-infrared wavelengths, with markedly linear response to changes in x-ray flux and energy. Monte Carlo modeling of incident flux and broadband, wide-field imaging of mouse phantoms bearing both Y{sub 2}O{sub 3}:Eu nanoparticles and calibrated LEDs of similar spectral emission demonstrated significant transmission of radioluminescence, in agreement with spectroscopic studies; with approximately 15 visible photons being generated for every x-ray photon incident. Unlike the dosimeters currently employed in clinical practice, these nanodosimeters can sample both dose and dose rate rapidly enough as to provide real-time feedback for x-ray based external beam radiotherapy (EBRT). The technique's use of remote sensing and absence of supporting structures enable perturbation-free dosing of the targeted region and complete sampling from any direction. With the conjugation of pathology-targeting ligands onto their surfaces, these nanodosimeters offer a potential paradigm shift in the real-time monitoring and modulation of delivered dose in the EBRT of cancer in situ.

36 MATERIALS SCIENCE↗

A multi-threshold sampling method for TOF PET signal processing

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multithreshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25 x 6.25 x 25mm{sup 3} LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an {approx}18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an {approx}9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain {approx}300 ps coincidence timing resolution, {approx}14% energy resolution at 511 keV, and {approx}5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced data visualization and sensor fusion: Conversion of techniques from medical imaging to Earth science

Hughes Aircraft Company and the University of Chicago propose to transfer existing medical imaging registration algorithms to the area of multi-sensor data fusion. The University of Chicago's algorithms have been successfully demonstrated to provide pixel by pixel comparison capability for medical sensors with different characteristics. The research will attempt to fuse GOES (Geostationary Operational Environmental Satellite), AVHRR (Advanced Very High Resolution Radiometer), and SSM/I (Special Sensor Microwave Imager) sensor data which will benefit a wide range of researchers. The algorithms will utilize data visualization and algorithm development tools created by Hughes in its EOSDIS (Earth Observation SystemData/Information System) prototyping. This will maximize the work on the fusion algorithms since support software (e.g. input/output routines) will already exist. The research will produce a portable software library with documentation for use by other researchers.

Savage, Richard C.↗

Advanced data visualization and sensor fusion: Conversion of techniques from medical imaging to Earth science

Hughes Aircraft Company and the University of Chicago propose to transfer existing medical imaging registration algorithms to the area of multi-sensor data fusion. The University of Chicago's algorithms have been successfully demonstrated to provide pixel by pixel comparison capability for medical sensors with different characteristics. The research will attempt to fuse GOES, AVHRR, and SSM/I sensor data which will benefit a wide range of researchers. The algorithms will utilize data visualization and algorithm development tools created by Hughes in its EOSDIS prototyping. This will maximize the work on the fusion algorithms since support software (e.g. input/output routines) will already exist. The research will produce a portable software library with documentation for use by other researchers.

Savage, Richard C.↗