Search NASA⌕ Search

Engineering topics

Chen, J

Publications and source records attributed to Chen, J.

At least 37 records · Page 2

SU-E-J-92: Validating Dose Uncertainty Estimates Produced by AUTODIRECT, An Automated Program to Evaluate Deformable Image Registration Accuracy

Purpose: Deformable image registration (DIR) is a powerful tool with the potential to deformably map dose from one computed-tomography (CT) image to another. Errors in the DIR, however, will produce errors in the transferred dose distribution. We have proposed a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), which predicts voxel-specific dose mapping errors on a patient-by-patient basis. This work validates the effectiveness of AUTODIRECT to predict dose mapping errors with virtual and physical phantom datasets. Methods: AUTODIRECT requires 4 inputs: moving and fixed CT images and two noise scans of a water phantom (for noise characterization). Then, AUTODIRECT uses algorithms to generate test deformations and applies them to the moving and fixed images (along with processing) to digitally create sets of test images, with known ground-truth deformations that are similar to the actual one. The clinical DIR algorithm is then applied to these test image sets (currently 4) . From these tests, AUTODIRECT generates spatial and dose uncertainty estimates for each image voxel based on a Student’s t distribution. This work compares these uncertainty estimates to the actual errors made by the Velocity Deformable Multi Pass algorithm on 11 virtual and 1 physical phantom datasets. Results: For 11 of the 12 tests, the predicted dose error distributions from AUTODIRECT are well matched to the actual error distributions within 1–6% for 10 virtual phantoms, and 9% for the physical phantom. For one of the cases though, the predictions underestimated the errors in the tail of the distribution. Conclusion: Overall, the AUTODIRECT algorithm performed well on the 12 phantom cases for Velocity and was shown to generate accurate estimates of dose warping uncertainty. AUTODIRECT is able to automatically generate patient-, organ- , and voxel-specific DIR uncertainty estimates. This ability would be useful for patient-specific DIR quality assurance.

60 APPLIED LIFE SCIENCES↗

SU-E-J-97: Quality Assurance of Deformable Image Registration Algorithms: How Realistic Should Phantoms Be?

Purpose: Deformable image registration (DIR) has widespread uses in radiotherapy for applications such as dose accumulation studies, multi-modality image fusion, and organ segmentation. The quality assurance (QA) of such algorithms, however, remains largely unimplemented. This work aims to determine how detailed a physical phantom needs to be to accurately perform QA of a DIR algorithm. Methods: Virtual prostate and head-and-neck phantoms, made from patient images, were used for this study. Both sets consist of an undeformed and deformed image pair. The images were processed to create additional image pairs with one through five homogeneous tissue levels using Otsu’s method. Realistic noise was then added to each image. The DIR algorithms from MIM and Velocity (Deformable Multipass) were applied to the original phantom images and the processed ones. The resulting deformations were then compared to the known warping. A higher number of tissue levels creates more contrast in an image and enables DIR algorithms to produce more accurate results. For this reason, error (distance between predicted and known deformation) is utilized as a metric to evaluate how many levels are required for a phantom to be a realistic patient proxy. Results: For the prostate image pairs, the mean error decreased from 1–2 tissue levels and remained constant for 3+ levels. The mean error reduction was 39% and 26% for Velocity and MIM respectively. For head and neck, mean error fell similarly through 2 levels and flattened with total reduction of 16% and 49% for Velocity and MIM. For Velocity, 3+ levels produced comparable accuracy as the actual patient images, whereas MIM showed further accuracy improvement. Conclusion: The number of tissue levels needed to produce an accurate patient proxy depends on the algorithm. For Velocity, three levels were enough, whereas five was still insufficient for MIM.

60 APPLIED LIFE SCIENCES↗

SU-E-J-165: Dosimetric Impact of Liver Rotations in Stereotactic Body Radiation Therapy

Purpose: Often in liver stereotactic body radiotherapy a single fiducial is implanted near the tumor for image-guided treatment delivery. In such cases, rotational corrections are calculated based on the spine. This study quantifies rotational differences between the spine and liver, and investigates the corresponding dosimetric impact. Methods: Seven patients with 3 intrahepatic fiducials and 4DCT scans were identified. The planning CT was separately co-registered with 4 phases of the 4DCT (0%, 50%, 100% inhale and 50% exhale) by 1) rigid registration of the spine, and 2) point-based registration of the 3 fiducials. Rotation vectors were calculated for each registration. Translational differences in fiducial positions between the 2 registrations methods were investigated. Dosimetric impact due to liver rotations and deformations was assessed using critical structures delineated on the 4DCT phases. For dose comparisons, a single fiducial was translationally aligned following spine alignment to represent what is typically done in the clinic. Results: On average, differences between spine and liver rotations during the 0%, 50%, 100% inhale, and 50% exhale phases were 3.23°, 3.27°, 2.26° and 3.11° (pitch), 3.00°, 2.24°, 3.12° and 1.73° (roll), and 1.57°, 1.98°, 2.09° and 1.36° (yaw), respectively. The maximum difference in rotations was 12°, with differences of >3° seen in 14/28 (pitch), 10/28 (roll), and 6/28 (yaw) cases. Average fiducial displacements of 2.73 (craniocaudal), 1.04 (lateral) and 1.82 mm (vertical) were seen. Evaluating percent dose differences for 5 patients at the peaks of the respiratory cycle, the maximum dose to the duodenum, stomach, bowel and esophagus differed on average by 11.4%, 5.3%, 11.2% and 49.1% between the 2 registration methods. Conclusion: Lack of accounting for liver rotation during treatment might Result in clinically significant dose differences to critical structures. Both rotational and translational deviations should be considered in planning margins when using spine alignment for liver treatments.

60 APPLIED LIFE SCIENCES↗

SU-E-T-17: A Comparison of Forward and Field in Field Intensity Modulation Radiotherapy Planning for Breast Cancer

Purpose: To compare the dosimetric difference in forward intensity modulation radiotherapy(fIMRT) and field in field IMRT (FIF IMRT)planning for breast cancer. Methods: Ten patients received radiotherapy are selected.For each patient,two treatment plans(fIMRT and FIF IMRT) were designed with Varian Eclipse ver11.0 treatment planning system.Evaluate the dose parameters of targets, organs at risk (OAR), monitor units and treatment time, using dose-volume histogram (DVH). Results: There were no significant difference were found in conformal index (CI), homogeneity index (HI) of PTV,V5,V10,V20,V30,V40,V50 of heart, lung and monitor unit(MU)(P>0.05).The differences were significant in the treatment time(fIMRT=8.3min,FIF IMRT=2.5,p<0.05). Conclusion: FIF IMRT is equal to fIMRT in dosimetril evaluation. Due to much less delivery time,FIF IMRT is an efficient technique in treating patients by reduceing the uncomfortable influnce which could effect the treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-125: Application of Jaw-Tracking Function in VMAT for Upper Thoracic Esophageal Cancer

Purpose: To explore the effect of the Jaw-tracking with RapidArc(JT-RapidArc) plans for upper thoracic esophageal cancer. Methods: Treatment planning was designed by using RapidArc and JT-RapidArc techniques for 11 consecutive patients. The dose-volume histogram parameters of PTV and the organs at risk(OAR), conformity index(CI), heterogeneity index(HI), low dose volume of normal tissue(B-P) and monitor units(MUs) were compared between the different techniques. Results: JT-RapidArc plans provided the better coverage of PTV1(64) D98 and HI(P<0.05), lower MLD, D2 of PTV1(64) and PTV2(54), but no statistically difference in CI(P>0.05), which comparison with RapidArc plans. Plans with JT- RapidArc had lower Lung of V5, V10, V13, V20, V30, MLD(P<0.05); heart of V20, MLD(P<0.05); and B-P of V5, V10, V15, V20, V30(P<0.05); but no significantly different in Spinal cord and SC-PRV as compared with RapidArc plans. JT-RapidArc plans increaseed the MUs by 1%(P>0.05) as compared with RapidArc plans. Conclusion: All of the plans had met the requirements of clinical dosimetry. JT-RapidArc plans as compared with RapidArc plans, showing better part of target coverage, part of OARS(lung and heart) and heart and B-P sparing, which MUs was slightly increased. This work was sponsored by Shantou University Medical College Clinical Research Enhancement Initiative(NO.201424)

60 APPLIED LIFE SCIENCES↗

SU-E-T-810: Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Non-Small-Cell Lung Cancer with Simultaneously Integrated Boost Radiation Therapy: A Planning Comparison Study

Purpose: To compare and analyze the characteristics of intensity-modulated arc therapy(IMAT) versus fixed-gantry intensity-modulated radiotherapy(IMRT) in treatment of non-small-cell lung cancer. Methods: Twelve patients treated in our radiotherapy center were selected for this study. The patient subsequently underwent 4D-CT simulation.Margins of 5mm and 10mm were added to the ITV to generate the CTV and PTV respectively. Three treatment plans (IMRT,one single arc (RA1),double arcs (RA2))were generated with Eclipse ver.8.6 planning systems. Using a dose level of 75Gy in 15fractions to the ITV,60Gy in 15fractions to the CTV and 45Gy in 15fractions to the PTV respectively. The target and normol tissue volumes were compared,as were the dosimetry parameters. Results: There were no significant differences in CI of ITV,PTV,HI of ITV,CTV and PTV, V5,V10,V15,V20,V25,V30,V45,V50 of total-lung and mean lung dose (all p>0.05). However, the differences were significant in terms of CI of CTV,V5 of B-P (all p<0.05). On the MU, IMRT=1540MU,RA1=1006 MU and RA2=1096 MU. (F=12.00,P=0.000).On the treatment time, IMRT= 13.5min,RA1= 1.5min,and RA2=2.5 min (F= 30.11,P=0.000 ). Conclusion: IMAT is equal to IMRT in dosimetril evaluation. Due to much less Mu and delivery time,IMAT is an ideal technique in treating patients by reduceing the uncomfortable influnce which could effect the treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-207-09: Evaluating the Dosimetric Accuracy of Extended Field-Of-View CT Reconstructions Using Clinical Data with Real Patient Geometries

Purpose: To determine the accuracy of dose calculations performed with CT images reconstructed using extended field of view (FOV) algorithms. Methods: In this study we selected 6 radiotherapy patients (3 head and neck & 3 chest/pelvis) whose body circumferences extended past the 50 cm scan FOV in the treatment planning CT. Images acquired on a Siemens Sensation Open scanner, were reconstructed using the standard FOV (sFOV) and two different extended FOV algorithms, eFOV and HDFOV. A physician and dosimetrist identified the radiation target, critical organs, and external patient contour. A benchmark CT was created for each patient, consisting of an average of the 3 CT reconstructions with a density override applied to regions containing truncation artifacts, and was used to create an optimal radiation treatment plan. The plan was copied onto each reconstruction without density override and dose was recalculated. Results: The native sFOV dose calculations had the largest deviation from the benchmark (0.4 – 6.0%). Both the HDFOV and eFOV calculations showed improvement over the sFOV. For patients with a smooth patient contour, the HDFOV calculation had the least deviation from the benchmark (0.1–0.5%) compared to eFOV (0.4–1.8%). In cases with large amounts of tissue and irregular skin folds, the eFOV deviated the least from the benchmark (0.2–0.6%) compared to HDFOV (1.3–1.8%). It was observed that the eFOV scan has large image artifact in air with an average HU of −600 compared to the ideal of −1000. In these cases, the artifact in air appears to attenuate the dose and compensate for the missing tissue density. The HDFOV demonstrated minimal artifact in air. Conclusion: Both eFOV and HDFOV provide improved dose calculation accuracy. The HDFOV reconstruction provides a clearer patient border than the eFOV allowing for well-defined density overrides to be applied with minimal air artifact. This research was supported by Siemens Medical Solutions.

60 APPLIED LIFE SCIENCES↗

WE-G-207-04: Non-Local Total-Variation (NLTV) Combined with Reweighted L1-Norm for Compressed Sensing Based CT Reconstruction

Purpose: Compressed sensing (CS) has been used for CT (4DCT/CBCT) reconstruction with few projections to reduce dose of radiation. Total-variation (TV) in L1-minimization (min.) with local information is the prevalent technique in CS, while it can be prone to noise. To address the problem, this work proposes to apply a new image processing technique, called non-local TV (NLTV), to CS based CT reconstruction, and incorporate reweighted L1-norm into it for more precise reconstruction. Methods: TV minimizes intensity variations by considering two local neighboring voxels, which can be prone to noise, possibly damaging the reconstructed CT image. NLTV, contrarily, utilizes more global information by computing a weight function of current voxel relative to surrounding search area. In fact, it might be challenging to obtain an optimal solution due to difficulty in defining the weight function with appropriate parameters. Introducing reweighted L1-min., designed for approximation to ideal L0-min., can reduce the dependence on defining the weight function, therefore improving accuracy of the solution. This work implemented the NLTV combined with reweighted L1-min. by Split Bregman Iterative method. For evaluation, a noisy digital phantom and a pelvic CT images are employed to compare the quality of images reconstructed by TV, NLTV and reweighted NLTV. Results: In both cases, conventional and reweighted NLTV outperform TV min. in signal-to-noise ratio (SNR) and root-mean squared errors of the reconstructed images. Relative to conventional NLTV, NLTV with reweighted L1-norm was able to slightly improve SNR, while greatly increasing the contrast between tissues due to additional iterative reweighting process. Conclusion: NLTV min. can provide more precise compressed sensing based CT image reconstruction by incorporating the reweighted L1-norm, while maintaining greater robustness to the noise effect than TV min.

60 APPLIED LIFE SCIENCES↗

Size- and Composition-Dependent Radio Frequency Magnetic Permeability of Iron Oxide Nanocrystals

We investigate the size- and composition-dependent ac magnetic permeability of superparamagnetic iron oxide nanocrystals for radio frequency (RF) applications. The nanocrystals are obtained through high-temperature decomposition synthesis, and their stoichiometry is determined by Mossbauer spectroscopy. Two sets of oxides are studied: (a) as-synthesized magnetite-rich and (b) aged maghemite nanocrystals. All nanocrystalline samples are confirmed to be in the superparamagnetic state at room temperature by SQUID magnetometry. Through the one-turn inductor method, the ac magnetic properties of the nanocrystalline oxides are characterized. In magnetite-rich iron oxide nanocrystals, size-dependent magnetic permeability is not observed, while maghemite iron oxide nanocrystals show clear size dependence. The inductance, resistance, and quality factor of hand-wound inductors with a superparamagnetic composite core are measured. The superparamagnetic nanocrystals are successfully embedded into hand-wound inductors to function as inductor cores.

Yun, H↗

Sci—Fri AM: Mountain — 05: Unified Optimization and Delivery of Intensity-modulated Radiation Therapy and Volume-modulated Arc Therapy

Purpose: To study the feasibility of a unified intensity-modulated arc therapy (UIMAT) that combines IMRT and VMAT optimization and delivery in order to produce efficient and superior radiation treatment plans. Methods: Inverse planning for UIMAT was prototyped on the Pinnacle treatment planning system (Philips Medical Systems). UIMAT integrates IMRT and VMAT delivery in the same arc where IMRT was delivered with gantry speed close to zero. Optimal gantry angles for the IMRT phases were selected automatically by the inverse optimization algorithm. Optimization of the VMAT phases and IMRT phases were done simultaneously using Pinnacle's direct machine parameter optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using our unified technique and compared with clinical VMAT or IMRT plans. Delivery verification was performed on an ArcCheck phantom (Sun Nuclear) and delivered in clinical mode on a Varian TrueBeam linear accelerator. Results: In this prototype implementation, compared to the VMAT or IMRT plans, with the plans normalized to the same dose coverage to the planning target volumes, the UIMAT plans produced improved OAR sparing for head and neck cases, while for lung and prostate cases, the dosimetric improvements for OARs were not as significant. In this proof-of-concept work, we demonstrated that a novel radiation therapy delivery technique combining VMAT and IMRT delivery in the same arc is feasible. Initial results showed UIMAT has the potential to be superior to either standard IMRT or VMAT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-633: Dose Differences in Lung Cancer SBRT: The Influences of MLC Width

Purpose: The aim is to compare the plan dose distribution of lung SBRT with MLCs in different width. Methods: Cases with phase INSCLC were enrolled. 9 cases were undergone 4D-CT scanning in the supine position with both arms raised. 3D-CT images without IV contrast were afterwards acquired with 3mm thickness and used for dose calculations. ITV was generated by using the inspiration and expiration images. The ITV can be expanded by geometric set-up uncertainty (5 mm) to generate the PTV. All chest normal tissues including chest wall were contoured by doctors. A total dose of 55 Gy will be given in 5 fractions within 10–14 days with an inter fraction interval of 2–3 days. Guided by the RTOG trial 3502 protocol, 11–13 non-coplanar fields with 6MV photon were arranged. Three types of MLCs with width of 3mm, 5mm and 10mm at isocenter position, were used separately to generate a CRT plan for each case. Monte Carlo algorithm was applied to dose calculation. All plans were adjusted as possible to meet the dose constraints. Dose-volume parameters from plans as followed were compared and analysized: PTV V55Gy, COMPTV D70% (70% of normalization dose), volume A (body minus PTV), and R100% and R50% (the ratio of x% of prescription dose isoline volume to PTV volume). Results: MLCs, 3mm and 5mm wide, played the identical roles on dosimetry of the plans, excluding the parameter volume A (p<0.05). On the contrary, MLC with width of 10mm was significantly inferior to the other two types on most parameters (p<0.05). For R50%, all types contributed equally (p>0.05). Conclusion: For lung cancer SBRT, MLC width had influence to dosimetry, especially in irradiation area. Small size MLC, e.g. 3mm and 5mm, are helpful to generate a high quality treatment plan, which could meet the strict criteria for targets and OAR.

60 APPLIED LIFE SCIENCES↗

TH-A-18A-01: Innovation in Clinical Breast Imaging

Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists. In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-02: Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Stage I and II Peripheral Lung Tumors with Unflattened Beams

Purpose: The full arcs strategy used in SBRT with RapidArc and unflattened (FFF) beams in large and heterogeneous peripheral non-smallcell lung cancer (NSCLC) appears to be suboptimal as it increases the disadvantageous dose to the contralateral lung, which potentially increases the toxicity to surrounding tissues. In this study, we investigated, for the first time, the dose delivery strategies using partial arcs (PA) and the fully rotational arcs with avoidance sectors (FAAS) for SBRT with FFF beams in peripheral NSCLC patients. Methods: Eighteen patients with NSCLC (stage I and II) were selected for this study. Nine patients with a GTV <= 10cc were designated as the small tumor group. The remaining nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OAR), total MU, out-of-field dose, and delivery time were analyzed. Delta4 and Portal dosimetry were employed to evaluate the delivery accuracy. Results: or the small tumor group, the FAAS plans significantly achieved a better conformity index, the lower total MU and out-of-field dose, a shorter treatment time, and the reduced doses to cord, heart, and lung (p < 0.05). But the target doses were slightly higher than that delivered by PA plans. For the large tumor group, the PA plans significantly attained a better conformity index and a shorter treatment time (p < 0.05). Furthermore, all plans achieved a high pass rate, with all the gamma indices greater than 97% at the Γ{sub 3mm,} {sub 3%} threshold. Conclusion: This study suggests that FAAS strategy is more beneficial for small tumor patients undergoing lung SBRT with FFF beams. However, for large tumor patients, PA strategy is recommended. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

SU-C-18A-05: Registration Accuracy of MR-Based Images to On-Board Megavoltage Cone-Beam CT for Brain Patient Setup

Purpose: To quantify the difference in isocenter shifts when co-registering MR and MR-based pseudo CTs (pCT) with on-board megavoltage conebeam CT (CBCT) images. Methods: Fast Spoiled Gradient Echo MRs were used to generate pCTs (research version of Advantage Sim MD™, GE Healthcare) for ten patients who had prior brain radiotherapy. The planning CT (rCT) for each was co-registered with the MR, and the plan isocenter and two other reference points were transferred to the MR and pCT. CBCT images (with the machine isocenter) from a single treatment day were coregistered with the 3 test images (MR, pCT and rCT), by two observers and by an automated registration algorithm. The reference points were used to calculate patient shifts and rotations from the registrations. The shifts calculated from the test image registrations were compared to each other and to the shifts performed by the therapists who treated the patients on that day. Results: The average difference in absolute value between the isocenter shifts from the MR-, pCT- and rCT-CBCT registrations, and the therapist shifts, were 2.02, 3.01 and 0.89 mm (craniocaudal), 1.14, 1.34 and 0.46 mm (lateral), and 1.37, 3.43 and 1.43 mm (vertical), respectively. The MR- and pCT-CBCT registrations differed by 1.99, and 2.53 mm (craniocaudal), 1.36, and 1.37 mm (lateral), and 0.74 and 2.34 mm (vertical), respectively, from the average rCT-CBCT shifts. On average, differences of 2.39 (craniocaudal), 1.28 (lateral) and 2.84 mm (vertical) were seen between the MR and pCT shifts. Rotations relative to the CBCT coordinate system were on average <2° for the MR and rCT, and <6° for the pCT. Conclusion: In this study, FSPGR MR-CBCT registrations were more precise compared to the pCT-CBCT registrations. For improved accuracy, MR sequences that are optimal for bony anatomy visualization are necessary. GE healthcare has provided a research version of Advantage Sim MD to UCSF. No financial support was provided.

60 APPLIED LIFE SCIENCES↗

SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity differences between primary and lymphoma tumor by multi-scale image texture analysis. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

62 RADIOLOGY AND NUCLEAR MEDICINE↗