Characterization of Secondary Drops Using Digital In-line Holography.
Abstract Not Provided
Engineering topics
Publications and source records attributed to Chen, Jun.
Abstract Not Provided
Abstract not provided.
Abstract not provided.
The accuracy of digital in-line holography to detect particle position and size within a 3D domain is evaluated with particular focus placed on detection of nonspherical particles. Dimensionless models are proposed for simulation of holograms from single particles, and these models are used to evaluate the uncertainty of existing particle detection methods. From the lessons learned, a new hybrid method is proposed. This method features automatic determination of optimum thresholds, and simulations indicate improved accuracy compared to alternative methods. To validate this, experiments are performed using quasi-stationary, 3D particle fields with imposed translations. For the spherical particles considered in experiments, the proposed hybrid method resolves mean particle concentration and size to within 4% of the actual value, while the standard deviation of particle depth is less than two particle diameters. Initial experimental results for nonspherical particles reveal similar performance.
Abstract Not Provided
Abstract Not Provided
Disclosed are a method and system for video compression, wherein the video encoder has low computational complexity and high compression efficiency. The disclosed system comprises a video encoder and a video decoder, wherein the method for encoding includes the steps of converting a source frame into a space-frequency representation; estimating conditional statistics of at least one vector of space-frequency coefficients; estimating encoding rates based on the said conditional statistics; and applying Slepian-Wolf codes with the said computed encoding rates. The preferred method for decoding includes the steps of; generating a side-information vector of frequency coefficients based on previously decoded source data, encoder statistics, and previous reconstructions of the source frequency vector; and performing Slepian-Wolf decoding of at least one source frequency vector based on the generated side-information, the Slepian-Wolf code bits and the encoder statistics.
We study the constraints on the cosmic opacity using the latest BAO and Union2 SNIa data in this paper and find that the best fit values seem to indicate that an opaque universe is preferred in redshift regions 0.20-0.35, 0.35-0.44 and 0.60-0.73, whereas, a transparent universe is favored in redshift regions 0.106-0.20, 0.44-0.57 and 0.57-0.60. However, our result is still consistent with a transparent universe at the 1σ confidence level, even though the best-fit cosmic opacity oscillates between zero and some nonzero values as the redshift varies.
G protein-coupled receptor kinase 2 (GRK2) is a well-established therapeutic target for the treatment of heart failure. In this paper we identify the selective serotonin reuptake inhibitor (SSRI) paroxetine as a selective inhibitor of GRK2 activity both in vitro and in living cells. In the crystal structure of the GRK2·paroxetine–Gβγ complex, paroxetine binds in the active site of GRK2 and stabilizes the kinase domain in a novel conformation in which a unique regulatory loop forms part of the ligand binding site. Isolated cardiomyocytes show increased isoproterenol-induced shortening and contraction amplitude in the presence of paroxetine, and pretreatment of mice with paroxetine before isoproterenol significantly increases left ventricular inotropic reserve in vivo with no significant effect on heart rate. Neither is observed in the presence of the SSRI fluoxetine. Our structural and functional results validate a widely available drug as a selective chemical probe for GRK2 and represent a starting point for the rational design of more potent and specific GRK2 inhibitors.
Abstract not provided.
Abstract Not Provided
We describe the development of a novel series of N-aryl-benzimidazolone HSP90 inhibitors (9) targeting the N-terminal ATP-ase site. SAR development was influenced by structure-based design based around X-ray structures of ligand bound HSP90 complexes. Lead compounds exhibited high binding affinities, ATP-ase inhibition and cellular client protein degradation.
Abstract Not Provided
We have epitaxially grown undoped {beta}-FeSi{sub 2} films on Si(111) substrates via atomic-hydrogen-assisted molecular-beam epitaxy. {beta}-FeSi{sub 2} films grown without atomic hydrogen exhibited p-type conduction with a hole density of over 10{sup 19} cm{sup -3} at room temperature (RT). In contrast, those prepared with atomic hydrogen showed n-type conduction and had a residual electron density that was more than two orders of magnitude lower than the hole density of films grown without atomic hydrogen (of the order of 10{sup 16} cm{sup -3} at RT). The minority-carrier diffusion length was estimated to be approximately 16 {mu}m using an electron-beam-induced current technique; this value is twice as large as that for {beta}-FeSi{sub 2} prepared without atomic hydrogen. This result could be well explained in terms of the minority-carrier lifetimes measured by a microwave photoconductance decay technique. The 1/e decay time using a 904 nm laser pulse was approximately 17 {mu}s, which is much longer than that for {beta}-FeSi{sub 2} prepared without atomic hydrogen (3 {mu}s). The photoresponsivity reached 13 mA/W at 1.31 {mu}m, which is the highest value ever reported for {beta}-FeSi{sub 2} films.
We present an experimental study of the mixing processes in a gravity current. The turbulent transport of momentum and buoyancy can be described in a very direct and compact form by a Prandtl mixing length model: the turbulent vertical fluxes of momentum and buoyancy are found to scale quadratically with the vertical mean gradients of velocity and density. The scaling coefficient is the square of the mixing lenth, approximately constant over the mixing zone of the stratified shear layer. We show how, in different flow configurations, this length can be related to the shear length of the flow ({var_epsilon}/{partial_derivative}{sub z}u{sup 3}){sup 1/2}. We also study the fluctuations of the momentum and density turbulent fluxes, showing how they relate to the mixing phenomena, and to the entrainment/detrainment balance.
With photon-number resolving detectors, we show compression of interference fringes with increasing photon numbers for a Fabry-Perot interferometer. This feature provides a higher precision in determining the position of the interference maxima compared to a classical detection strategy. We also theoretically show supersensitivity if N-photon states are sent into the interferometer and a photon-number resolving measurement is performed.
We present an experimental study of the mixing processes in a gravity current. The turbulent transport of momentum and buoyancy can be described in a very direct and compact form by a Prandtl mixing length model [1]: the turbulent vertical fluxes of momentum and buoyancy are found to scale quadraticatly with the vertical mean gradients of velocity and density. The scaling coefficient is the square of the mixing length, approximately constant over the mixing zone of the stratified shear layer. We show in this paper how, in different flow configurations, this length can be related to the shear length of the flow {radical}({var_epsilon}/{partial_derivative}{sub z}u{sup 3}).
The Pb-2.2 wt pct Sb alloy has been directionally solidified in 1-, 2-, 3-, and 7-mm-diameter crucibles with planar and dendritic liquid-solid interface orphology. For plane front solidification, the experimentally observed macrosegregation along the solidified length follows the relationship proposed by Favier. Application of a 0.4 T transverse magnetic field has no effect on the extent of convection. Reducing the ampoule diameter appears to decrease the extent of convection. However, extensive convection is still present even in the 1-mm-diameter crucible. An extrapolation of the observed behavior indicated that nearly diffusive transport conditions require ampoules that are about 40 microns in diameter. Reduction of the crucible diameter does not appear to have any significant effect on the primary dendrite spacing. However, it results in considerable distortion of the dendrite morphology and ordering. This is especially true for the 1-mm diameter samples.