Search NASA⌕ Search

Engineering topics

Chen, Nicole

Publications and source records attributed to Chen, Nicole.

Preparing for Mars 2020 and Future Space Missions: Technology Advancements Driving Contamination Control Requirements and Cleanroom Protocols

Future space exploration missions will force contamination control requirements to become more strict to support increasingly sensitive instrumentation and search for life missions. Driving issues for these extremely clean requirements include increased instrument sensitivity, return sample science, and protecting ambitious mission science objectives. Preparing to meet these requirements mandates that contamination control provide new guidelines and more involved support for the cleanrooms during flight hardware assembly, including establishing better methods for setting cleanroom personnel limits to reduce particle fall out in cleanrooms. Limited literature exists for universal methods of determining cleanroom personnel limits, and what does exist includes mostly theory and assumptions on determining the limit. In this work, published method will be assessed against particle fall out data collected from the ISO 5 cleanrooms of the Mars 2020 Perseverance Rover assembly. Additional evaluations will assess contamination control required cleanroom protocols and the overall success of meeting strict cleanliness requirements of the Adaptive Caching Assembly (ACA) and sample tubes to safeguard future scientific endeavors.

Chen, Nicole↗

Modelling and Laboratory Testing of Particle Resuspension and Transport for the Assessment of Terrestrial-Borne Biological Contamination of the Samples on the Mars 2020 Mission

The Mars 2020 mission will land a rover on the surface of Mars that will acquire, encapsulate, and cache scientifically selected samples of martian material for possible return to Earth by a future mission. The samples will be individually encapsulated and sealed in sample tubes. Each sample, and therefore each sample tube, must be kept clean of viable organisms with a terrestrial origin, which may adhere to the rover on their own and/or on other non-biological particles. Therefore, contrary to previous missions to the Red Planet, Mars 2020 is subject to new and more stringent biological, organic and inorganic contamination requirements. This paper reports on the analyses and testing performed to assess the various vectors that can lead to the terrestrial-borne contamination of the samples, focusing on those that are predicted to be the larger contributors. Specifically, the contamination of the sample tubes is expected to be very small prior to the commencement of the mission’s science phase since these tubes are protected by so-called Fluid Mechanical Particle Barriers. Once on the surface of Mars however the sample tubes will be removed from their FMPBs and be subject to contamination from the rover. Of specific interest is the vector by which winds dislodge some particles from the surface of the rover and transport them to the surrounding soil. Naturally, such assessments require multi-disciplinary analyses involving at minimum the physics of particle adhesion and resuspension from surfaces, fluid mechanics and aerosols. Here we provide an overview of these models. We also report on particle resuspension experiments we have performed at the Jet Propulsion Laboratory to both guide and validate the aforementioned physics models.

Steltzner, Adam↗

Analysis of CO2 Composite Spray Cleaning System Results

In a previous study, the cleaning efficiency of a CO2 composite cleaning system for particulate removal was tested. The study covered particles from spores to fluorescent particles of different sizes as well as a variety of substrate surfaces, including aluminum, titanium, stainless steel, and nitinol. Particles were deposited using aerosol (dry) and droplet (wet) deposition. Results from the previous study show that the CO2 composite spray system is capable of cleaning to sterility for aerosol deposited spores and is capable of cleaning a minimum of a 4-log reduction for droplet deposited spores. This minimum 4-log reduction matches current Planetary Protection dry heat microbial reduction requirements. In this paper we will present new data to further correlate the cleaning efficiency with how contamination was introduced to the surface, the surface roughness, and particle size. Possible causes for such correlations will be discussed.

Chung, Shirley↗

Particulate Removal Using a CO2 Composite Spray Cleaning System

The Planetary Protection surface cleanliness requirements for potential Mars Sample Return hardware that would come in contact with Martian samples may be stricter than previous missions. The Jet Propulsion Laboratory has developed a new technology that will enable us to remove sub-micron size particles from critical hardware surfaces. A hand-held CO2 composite cleaning system was tested to verify its cleaning capabilities. This convenient, portable device can be used in cleanrooms for cleaning after rework or during spacecraft integration and assembly. It is environmentally safe and easy to use. This cleaning concept has the potential to be further developed into a robotic cleaning device on a Mars Lander to be used to clean sample acquisition or sample handling devices in situ. Contaminants of known sizes and concentrations, such as fluorescent microspheres and spores were deposited on common spacecraft material surfaces. The cleaning efficiency results will be presented and discussed.

carbon dioxide↗