Improved Double Pulse Test for Accurate Dynamic Characterization of Medium Voltage SiC Devices
This article presents an improved double pulse test (DPT) for accurate dynamic characterization of the medium voltage (MV) silicon carbide device. The difference between low voltage (LV) and MV DPT setup grounding is first introduced, which results in different measurement considerations. Then, parasitic capacitances in the DPT and their impact on the DPT are discussed considering different grounding points and device connections. Approaches are proposed to minimize the impact of parasitic capacitances on DPT results. In addition, the impact of switching V-I timing alignment on the testing results is discussed, compared to that in the LV DPT; a V-I alignment approach is introduced for the MV DPT. A 10 kV/20 A SiC mosfet -based DPT is taken as an example of the improved DPT, and test results show that it can minimize the impact from parasitic and improve the accuracy of the device switching loss estimation.
SiC and GaN Devices With Cryogenic Cooling
This article presents the cryogenically cooled application for wide bandgap (WBG) semiconductor devices. Characteristics of silicon carbide (SiC) and gallium nitride (GaN) at cryogenic temperatures are illustrated. SiC MOSFETs exhibit increased on-state resistance and slower switching speed at cryogenic temperatures. However, cryogenic cooling provides low ambient temperature environment and thus enables the SiC converter to operate at lower junction temperature to achieve higher efficiency compared to room temperature cooling. A cryogenically cooled MW-level SiC inverter prototype is developed and demonstrated the feasibility of operating high-power SiC converter with cryogenic cooling. GaN HEMTs exhibit more than five times on-state resistance reduction and faster switching speed at cryogenic temperatures which makes GaN HEMTs an excellent candidate for cryogenic power electronics applications. The significantly reduced on-state resistance of GaN devices provides the possibility to operate them at a current level much higher than rated current at cryogenic temperatures. A GaN double pulse test (DPT) circuit is constructed and demonstrated that GaN HEMTs can operate at nearly four times of rated current at cryogenic temperatures. Challenges of utilizing WBG device with cryogenic cooling are discussed and summarized.
Balanced stochastic versus deterministic assembly processes benefit diverse yet uneven ecosystem functions in representative agroecosystems
Ecological assembly processes, by influencing community composition, determine ecosystem functions of microbiomes. However, debate remains on how stochastic versus deterministic assembly processes influence ecosystem functions such as carbon and nutrient cycling. Towards a better understanding, we investigated three types of agroecosystems (the upland, paddy, and flooded) that represent a gradient of stochastic versus deterministic assembly processes. Carbon and nutrient cycling multifunctionality, characterized by nine enzymes associated with soil carbon, nitrogen, phosphorous and sulfur cycling, was evaluated and then associated with microbial assembly processes and cooccurrence patterns of vital ecological groups. Our results suggest that strong deterministic processes favour microorganisms with convergent functions (as in the upland agroecosystem), while stochasticity-dominated processes lead to divergent functions (as in the flooded agroecosystem). To benefit agroecosystems services, we speculate that it is critical for a system to maintain balance between its stochastic and deterministic assembly processes (as in the paddy agroecosystem). By doing so, the system can preserve a diverse array of functional traits and also allow for particular traits to flourish. To further confirm this speculation, it is necessary to develop a systematic knowledge beyond merely characterizing general patterns towards the associations among community assembly, composition, and ecosystem functions.
Straw chemistry links the assembly of bacterial communities to decomposition in paddy soils
Not Available
Methodology of Low Inductance Busbar Design for Three-Level Converters
Three-level (3L) converters are more susceptible to parasitics compared with two-level converters because of their complicated structure with multiple switching loops. In this article, the methodology of busbar layout design for 3L converters based on the magnetic cancellation effect is presented. The methodology can fit for 3L converters with symmetric and asymmetric configurations. A detailed design example is provided for a high-power 3L-active neutral point clamped (ANPC) converter, which includes the module selection, busbar layout, and dc-link capacitor placement. The loop inductance of the busbar is verified with simulation, impedance measurements, and converter experiments. Furthermore, the results match with each other, and the inductances of short and long loops are 6.5 and 17.5 nH, respectively, which are significantly lower than the busbars of NPC-type converters in other references.
Characterization and Failure Analysis of 650-V Enhancement-Mode GaN HEMT for Cryogenically Cooled Power Electronics
In order to evaluate the feasibility of newly developed gallium nitride (GaN) devices in a cryogenically cooled converter, this article characterizes a 650-V enhancement-mode GaN high-electron mobility transistor (GaN HEMT) at cryogenic temperatures. The characterization includes both static and dynamic behaviors. The results show that this GaN HEMT is an excellent device candidate to be applied in cryogenic-cooled applications. For example, transconductance at cryogenic temperature (93 K) is 2.5 times higher than one at room temperature (298 K), and accordingly, peak di / dt during turn-on transients at cryogenic temperature is around 2 times of that at room temperature. Moreover, the ON-resistance of the channel at the cryogenic temperature is only one-fifth of that at room temperature. The corresponding explanations of performance trends at cryogenic temperatures are also given from the view of semiconductor physics. In addition, several device failures were observed during the dynamic characterization of GaN HEMTs at cryogenic temperatures. Additionally, the ultrafast switching speed-induced high di / dt and dv / dt at cryogenic temperatures amplify the negative effects of parasitics inside the switching loop. Based on failure waveforms, two failure modes were classified, and detailed failure mechanisms caused by ultrafast switching speed are given in this article.
Design of Low Inductance Busbar for 500 kVA Three-Level ANPC Converter
The adoption of SiC devices in high power applications enables higher switching speed, which requires lower circuit parasitic inductance to reduce the voltage overshoot. This paper presents the design of a busbar for a 500 kVA three-level active natural clamped converter. The layout of the busbar is discussed in detail based on the analysis of the multiple commutation loops, magnetic cancelling effect, and DC-link capacitor placement. The loop inductance of the designed busbar is verified with simulation, impedance measurements and converter experiment. The results can match with each other and the inductances of small and large loop are 6.5 nH and 17.5 nH respectively, which is significantly lower than the busbars of NPC type converters in other references.
Harmonic Analysis of Common-mode Reduction Modulation for Three-level Inverter
This paper presents harmonic analysis of common-mode reduction (CMR) modulation for three-level voltage source inverters. The analytical model to calculate the harmonics of CMR modulation with arbitrary PWM sequence is developed. The impact of alternative PWM sequences of CMR modulation on harmonics is investigated. New three-state and four-state PWM sequences of CMR are proposed which spread the energy centered in the carrier frequency in the conventional CMR, and thus reduce the voltage peaks in frequency domain. Experiments are conducted on a three-level neutral point clamped inverter. Experiment results verify the developed analytical model and harmonic analysis.
Design of Low Inductance Busbar for 500 kVA Three-Level ANPC Converter
The adoption of SiC devices in high power applications enables higher switching speed, which requires lower circuit parasitic inductance to reduce the voltage overshoot. This paper presents the design of a busbar for a 500 kVA three-level active neutral point clamped (ANPC) converter. The layout of the busbar is discussed in detail based on the analysis of the multiple commutation loops, magnetic canceling effect, and DC-link capacitor placement. The loop inductance of the busbar is verified with simulation, impedance measurements, and converter experiments. The results match with each other, and the inductances of small and large loop are 6.5 nH and 17.5 nH respectively, which is significantly lower than the busbars of NPC type converters in other references.
MW-Class Cryogenically-Cooled Inverter for Electric Aircraft Applications
Explore the source record for details and available documents.
A Simple Control to Reduce the Voltage Stress of Non-Conducting Switches in Three-Level ANPC Converter
With the development of wide band-gap (WBG) technology, the switching speed of power semiconductor devices is increased, which makes circuits more sensitive to parasitics. For three-level active neutral point clamped (3L-ANPC) converters, the over-voltage of non-conducting switches can be an issue. This paper analyzes the multiple commutation loops in 3L-ANPC converter and summarizes the impact factors of the over-voltage for the non-conducting switch. It is found that the nonlinearity of the output capacitance of the device can significantly influence the over-voltage. A simple control without introducing any additional hardware circuit is proposed to attenuate the impact of the nonlinearity. With the proposed control, the peak over-voltage of the non-conducting switch can be reduced significantly. Multi-pulse test is conducted for a 3L- ANPC converter built with silicon carbide (SiC) MOSFETs. The testing results show that the peak over-voltage decreases from 892 V to 624 V with the proposed control. More detailed analysis and experimental results will be provided in the final paper.
Modeling of Multi-Loops Related Device Turn-On Overvoltage in 3L-ANPC Converters
The analytical model for the device drain-source turn-on overvoltage in three-level active neutral point clamped (3L-ANPC) converters is established in this paper. Considering the two commutation loops in the converter, the relationship between the overvoltage and the loop inductances is evaluated. The line switching frequency device usually exhibits higher overvoltage, while the high switching frequency device is not strongly influenced by the multiple loops. A 500 kVA 3L-ANPC converter using SiC MOSFETs is tested, and the model is verified with the experimental results.
Modeling of Multi-Loops Related Device Turn-On Overvoltage in 3L-ANPC Converters
An analytical model for the device drain-source turn-on overvoltage in three-level active neutral point clamped (3L-ANPC) converters is established in this paper. Considering the two commutation loops in the converter, the relationship between the turn-on overvoltage and the loop inductances is evaluated. The line switching frequency device usually exhibits higher overvoltage, while the high switching frequency device is not strongly influenced by the multiple loops. A 500 kVA 3L-ANPC converter using SiC MOSFETs is tested, and the model is verified with the experimental results.
Design of a Single Controller for Multiple Paralleled Inverters
Paralleling power electronics inverters is an effective way to increase dc-ac system power level. Accurately synchronized switching action and independent closed-loop regulator are necessary to prevent circulating current in paralleled inverters. There are many challenges for the controller design, when the number of paralleled inverters is large, and control period gets short for high switching frequency applications. This paper presents a single controller design based on DSP + FPGA that is suitable for paralleling multiple inverters. A simple synchronization scheme between DSP and FPGA based on universal parallel port (UPP) is proposed to eliminate the synchronization delay among inverters, and independent control of each converter can also be implemented. The controller is built for a system consisting of 4 paralleled three-level, three-phase high frequency ANPC inverters using space vector modulation, and it can be easily adopted to other topologies and modulations. Experimental results have demonstrated the effectiveness of this controller.
Coupled Inductor Design for Interleaved Three-level Active Neutral Point Clamped Inverters Considering EMI Noise Reduction
This paper presents the coupled inductor design for interleaved three-level active neutral point clamped (ANPC) inverter considering electromagnetic interference (EMI) noise reduction. Compared to two-level case, the scenarios involved in the three-level space vector modulation (SVM) are more complicated when analyzing the volt-seconds of the coupled inductor for paralleled three-level inverter. At system level, the purpose of converter interleaving is to reduce EMI noise and ripple current in most applications, and coupled inductor design should consider the needs of EMI noise reduction and EMI filter design. These issues are discussed in this paper. The relationship between circulating current and EMI noise is illustrated. EMI filter corner frequency as a function of interleaving angle is analytically derived, and optimal interleaving angle for maximum common-mode (CM) filter and differential-mode (DM) filter corner frequencies is discussed. Coupled inductor design methodology for interleaved three-level inverters with SVM is then presented. Experiments on two interleaved ANPC inverters are conducted. The results verify the coupled inductor design. With the derived optimal interleaving angle, the CM and DM EMI noise are significantly reduced.
Analytical Analysis of Ac and Dc Side Harmonics of Three-level Active Neutral Point Clamped Inverter with Space Vector Modulation
This paper presents a comprehensive analytical analysis of the ac and dc side harmonics of the three-level active neutral point clamped (ANPC) inverter with space vector modulation (SVM) scheme. An analytical model to calculate the harmonics of a three-level converter with SVM is developed. The ac side output voltage harmonics and dc side current harmonics characteristics are calculated and analyzed. With the developed models, the impact of interleaving on both sides harmonics are studied which considers the modulation index, interleaving angle, and power factor. The analysis provides guideline for interleaving angle optimization to reduce the ac side power filter and dc side dc-link capacitor. The relationship between electromagnetic interference (EMI) filter corner frequency and switching frequency is also analytically derived which provides guideline for switching frequency and EMI filter design optimization. Two paralleled three-level ANPC inverters are constructed and experimental results are presented to verify the analytical analysis.