Observation of e + e − → η ′ J / ψ at center-of-mass energies between 4.189 and 4.600 GeV
Not Available
Engineering topics
Publications and source records attributed to Chen, S..
Not Available
The Canadian Light Source (CLS) Quantum Materials Spectroscopy Center (QMSC) beamline will employ a novel double period (55 mm, 180 mm) elliptically polarizing undulator (EPU) to produce photons of arbitrary polarization in the soft X-ray regime. The long period and high field of the 180 mm period EPU will have a strong dynamic focusing effect on the storage ring electron beam. We have considered two partial correction schemes, a 4 m long planar array of BESSY-II style current strips, and soft iron L-shims. In this paper we briefly consider the implementation of these correction schemes.
Bionanoprobe (BNP), a hard x-ray fluorescence sample-scanning nanoprobe at the Advanced Photon Source of Argonne National Laboratory, has been used to quantitatively study elemental distributions in biological cells with sub-100 nm spatial resolution and high sensitivity. Cryogenic conditions enable biological samples to be studied in their frozen-hydrated state with both ultrastructure and elemental distributions more faithfully preserved compared to conventional chemical fixation or dehydration methods. Furthermore, radiation damage is reduced in two ways: the diffusion rate of free radicals is decreased at low temperatures; and the sample is embedded in vitrified ice, which reduces mass loss.
Here, by analyzing 2.93 fb -1 of data collected at √s = 3.773 GeV with the BESIII detector, we measure the absolute branching fraction B(D + → K¯ 0 μ + ν μ ) = (8.72 ± 0.07 stat. ± 0.18 sys. )%, which is consistent with previous measurements within uncertainties but with significantly improved precision. Combining the Particle Data Group values of B(D 0 → K - μ + ν μ ), B(D + → K¯ 0 e + ν e ), and the lifetimes of the D 0 and D + mesons with the value of B(D + → K¯ 0 μ + ν μ ) measured in this work, we determine the following ratios of partial widths: Γ(D 0 → K - μ + ν μ )/Γ(D + → K¯ 0 μ + ν μ ) = 0.963 ± 0.044 and Γ(D + → K¯ 0 μ + ν μ )/Γ(D + → K¯ 0 e + ν e ) = 0.988 ± 0.033.
Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.
Here, the recent combination of ultra-intense lasers and laser-accelerated electron beams is enabling the development of a new generation of compact x-ray light sources, the coherence of which depends directly on electron beam emittance. Although the emittance of accelerated electron beams can be low, it can grow due to the effects of space charge during free-space propagation. Direct experimental measurement of this important property is complicated by micron-scale beam sizes, and the presence of intense fields at the location where space charge acts. Reported here is a novel, non-destructive, single-shot method that overcame this problem. It employed an intense laser probe pulse, and spectroscopic imaging of the inverse-Compton scattered x-rays, allowing measurement of an ultra-low value for the normalized transverse emittance, 0.15 (±0.06) π mm mrad, as well as study of its subsequent growth upon exiting the accelerator. The technique and results are critical for designing multi-stage laser-wakefield accelerators, and generating high-brightness, spatially coherent x-rays.
Not Available
Ptychography has emerged as a nondestructive tool to quantitatively study extended samples at a high spatial resolution. In this manuscript, we report on recent developments from our team. We have combined cryo ptychography and fluorescence microscopy to provide simultaneous views of ultrastructure and elemental composition, we have developed multi-GPU parallel computation to speed up ptychographic reconstructions, and we have implemented fly-scan ptychography to allow for faster data acquisition. We conclude with a discussion of future challenges in high-resolution 3D ptychography.
Abstract not provided
In order to achieve energy conversion efficiencies of > 50 pct for steam turbines/boilers in power generation systems, materials are required that are both strong and corrosion-resistant at > 973 K (700 A degrees C), and economically viable. Austenitic steels strengthened with Laves phase, NiAl and Ni3Al precipitates, and alloyed with aluminum to improve oxidation resistance, are potential candidate materials for these applications. The microstructure and microchemistry of recently developed alumina-forming austenitic stainless steels have been characterized by scanning electron microscopy, transmission electron microscopy, and synchrotron X-ray diffraction. Different thermo-mechanical treatments were performed on these steels to improve their mechanical performance. These reduced the grain size significantly to the nanoscale (similar to 100 nm) and the room temperature yield strength to above 1000 MPa. A solutionizing anneal at 1473 K (1200 A degrees C) was found to be effective for uniformly redistributing the Laves phase precipitates that form upon casting. (C) The Minerals, Metals & Materials Society and ASM International 2015
A new measurement of the branching ratio R e/μ =Γ(π + → e + ν + π + → e + νγ)/Γ(π+ → μ+ν + π + →μ+νγ) resulted in R exp e/μ =[1.2344±0.0023(stat)±0.0019(syst)] x 10 -4 . This is in agreement with the standard model prediction and improves the test of electron-muon universality to the level of 0.1%.
Penning-Malmberg traps confining electron plasmas usually rely on external sources like thermo- and photocathodes. It has been already demonstrated that electron plasmas of comparable densities can be produced by applying a radio-frequency (RF) power to any inner electrode of the trap. Such excitation may result in significant electron heating and ionization of the residual gas with the formation of a plasma column when the RF frequency is of the order or larger than the typical axial bounce frequencies of few-eV electrons, even at RF amplitude of few volts. While discharges are common in plasma generation at higher pressures and RF power, this mechanism is not yet well explored in our working conditions, namely ultra-high vacuum and very low RF power. This plasma production mechanism is very sensitive to the experimental conditions. Interesting phenomena can be observed: transition from a diffuse to a narrow-section, denser plasma column; presence of low-order diocotron modes in transient and steady-state plasmas; modulation of the m=1 diocotron mode and suppression of its instability despite the presence of positive ions and resistive loads. These observations are reported here, and possible explanations are discussed. In addition, a possible electron heating mechanism is investigated with a single-particle, one-dimensional model described by an area-preserving map where an electron bounces within a square potential well and the RF excitation is modelled by a time-oscillating square barrier. The low-energy part of the Poincaré plot includes both quasi-periodic and chaotic regions, where heating up to ionization energies is achievable. Results of a systematic analysis of the map extracting its chaotic properties and scaling laws as a function of the control parameters are reported.
Complex (dusty) plasmas are characterized by the presence of a fraction of micrometric or sub-micrometric particles which may collect a surface charge up to the order of a few thousand electron charges. The dusty plasmas studied in the experiments generally satisfy a global neutrality condition. By contrast, we present here the investigation of a magnetized nonneutral plasma, i.e., a plasma with a single sign of charge (e.g. electrons) confined in a Penning-Malmberg trap, contaminated by a dust population. We simulate the two-dimensional transverse dynamics of this multi-component plasma with a particle-in-cell code implementing a mass-less fluid (drift-Poisson) approximation for the electrons and a kinetic description for the dust component (including gravity). Simulations with different initial dust distributions and densities have been performed in order to investigate the influence of the dust on the development of the diocotron instability in the electron plasma. In particular, the early stage of the growth of the diocotron modes has been analyzed by Fourier decomposition.