Engineering topics
Chen, Ting
Publications and source records attributed to Chen, Ting.
Carrier Transport in Films of Alkyl-Ligand-Terminated Silicon Nanocrystals
Silicon nanocrystals (Si NCs) have shown great promise for electroluminescent and photoluminescent applications. In order to optimize the properties of Si NC devices, however, electronic transport in Si NC films needs to be thoroughly understood. Here we present a systematic study of the temperature and electric field dependence of conductivity in films of alkyl-ligand-terminated Si NCs, which to date have shown the highest potential for device applications. Our measurements suggest that the conductivity is limited by the ionization of rare NCs containing donor impurities. At low bias, this ionization is thermally activated, with an ionization energy equal to twice the NC charging energy. As the bias is increased, the ionization energy is reduced by the electric field, as determined by the Poole-Frenkel effect. At large bias and sufficiently low temperature, we observe cold ionization of electrons from donor-containing NCs, with a characteristic tunneling length of about 1 nm. The temperature- and electric-field-dependent conductance measurements presented here provide a systematic and comprehensive picture for electron transport in lightly doped nanocrystal films.
High-pressure behavior and thermoelastic properties of niobium studied by in situ x-ray diffraction
In situ synchrotron energy dispersive x-ray diffraction (XRD) experiments on Nb have been conducted at pressures up to 6.4 GPa and temperatures up to 1073 K. From the pressure-volume-temperature measurements, thermoelastic parameters were derived for the first time for Nb based on the thermal pressure (ΔP{sub th}) equation of state (EOS), modified high-T Birch-Murnaghan EOS, and Mie-Grüneisen-Debye EOS. With the pressure derivative of the bulk modulus K{sub T}{sup ´} fixed at 4.0, we obtained the ambient isothermal bulk modulus K{sub T0}=174(5) GPa, the temperature derivative of bulk modulus at constant pressure (∂K{sub T}/∂T){sub P}=-0.060(8) GPa K⁻¹ and at constant volume (∂K{sub T}/∂T){sub V}=-0.046(8) GPa K⁻¹, the volumetric thermal expansivity α{sub T}(T)=2.3(3)×10⁻⁵+0.3(2)×10⁻⁸T (K⁻¹), as well as the pressure dependence of thermal expansion (∂α/∂P){sub T}=(₋2.0±0.4)×10⁻⁶ K⁻¹ GPa⁻¹. Fitting the present data to the Mie-Grüneisen-Debye EOS with Debye temperature Θ₀=276.6 K gives γ₀=1.27(8) and K{sub T0}=171(3) GPa at a fixed value of q=3.0. The ambient isothermal bulk modulus and Grüneisen parameter derived from this work are comparable to previously reported values from both experimental and theoretical studies. An in situ high-resolution, angle dispersive XRD study on Nb did not indicate any anomalous behavior related to pressure-induced electronic topological transitions at ~5 GPa as has been reported previously.
Influence of surface modifications on pitting corrosion behavior of nickel-base alloy 718. Part 2: Effect of aging treatment
Explore the source record for details and available documents.
Hypervalent surface interactions for colloidal stability and doping of silicon nanocrystals
Explore the source record for details and available documents.
A 3D global-to-local deformable mesh model based registration and anatomy-constrained segmentation method for image guided prostate radiotherapy
Purpose: In the external beam radiation treatment of prostate cancers, successful implementation of adaptive radiotherapy and conformal radiation dose delivery is highly dependent on precise and expeditious segmentation and registration of the prostate volume between the simulation and the treatment images. The purpose of this study is to develop a novel, fast, and accurate segmentation and registration method to increase the computational efficiency to meet the restricted clinical treatment time requirement in image guided radiotherapy. Methods: The method developed in this study used soft tissues to capture the transformation between the 3D planning CT (pCT) images and 3D cone-beam CT (CBCT) treatment images. The method incorporated a global-to-local deformable mesh model based registration framework as well as an automatic anatomy-constrained robust active shape model (ACRASM) based segmentation algorithm in the 3D CBCT images. The global registration was based on the mutual information method, and the local registration was to minimize the Euclidian distance of the corresponding nodal points from the global transformation of deformable mesh models, which implicitly used the information of the segmented target volume. The method was applied on six data sets of prostate cancer patients. Target volumes delineated by the same radiation oncologist on the pCT and CBCT were chosen as the benchmarks and were compared to the segmented and registered results. The distance-based and the volume-based estimators were used to quantitatively evaluate the results of segmentation and registration. Results: The ACRASM segmentation algorithm was compared to the original active shape model (ASM) algorithm by evaluating the values of the distance-based estimators. With respect to the corresponding benchmarks, the mean distance ranged from -0.85 to 0.84 mm for ACRASM and from -1.44 to 1.17 mm for ASM. The mean absolute distance ranged from 1.77 to 3.07 mm for ACRASM and from 2.45 to 6.54 mm for ASM. The volume overlap ratio ranged from 79% to 91% for ACRASM and from 44% to 80% for ASM. These data demonstrated that the segmentation results of ACRASM were in better agreement with the corresponding benchmarks than those of ASM. The developed registration algorithm was quantitatively evaluated by comparing the registered target volumes from the pCT to the benchmarks on the CBCT. The mean distance and the root mean square error ranged from 0.38 to 2.2 mm and from 0.45 to 2.36 mm, respectively, between the CBCT images and the registered pCT. The mean overlap ratio of the prostate volumes ranged from 85.2% to 95% after registration. The average time of the ACRASM-based segmentation was under 1 min. The average time of the global transformation was from 2 to 4 min on two 3D volumes and the average time of the local transformation was from 20 to 34 s on two deformable superquadrics mesh models. Conclusions: A novel and fast segmentation and deformable registration method was developed to capture the transformation between the planning and treatment images for external beam radiotherapy of prostate cancers. This method increases the computational efficiency and may provide foundation to achieve real time adaptive radiotherapy.
Determination of Top-of-Atmosphere Longwave Radiative Fluxes: A Comparison Between Two Approaches Using ScaRaB Data
Two conceptually different approaches (broadband-based ERBE and narrowband-based ISCCP approaches), used to derive the TOA longwave radiative fluxes, are compared using the ScaRaB simultaneous narrowband and broadband measurements. This study directly shows that the ERBE MLE-derived cloud covers implicitly contain some information on the cloud optical properties. A spurious view-zenith-angle dependence of the MLE scene identification scheme is confirmed by this study. Except for very thin cirrus clouds, differences between the ERBE and ISCCP approaches are in general < 10 W/sq m for the TOA LW radiative fluxes. For clear pixels, the model calculated (ISCCP approach) TOA LW radiances are systematically smaller than the observations. Though the bias is found to be correlated on the column precipitable water amount, the exact source of this discrepancy remains undetermined and merits further study. Compared with the radiative transfer model used in this study, the ERBE LW ADMs are too weakly limb-darkened for optically thin clouds, but too strongly limb-darkened for optically thick clouds, indicating that more accurate instantaneous TOA LW flux estimations from the ERBE approach would require additional cloud classes based on cloud height and optical thickness.