Search NASASearch

Engineering topics

Chen, W.

Publications and source records attributed to Chen, W..

36 records · Page 2

Mid-infrared trace gas detection using continuous-wave difference frequency generation in periodically poled RbTiOAsO4

A tunable mid-infrared continuous-wave (cw) spectroscopic source in the 3.4-4.5 micrometers region is reported, based on difference frequency generation (DFG) in a quasi-phase-matched periodically poled RbTiOAsO4 (PPRTA) crystal. DFG power levels of 10 microW were generated at approximately 4 micrometers in a 20-mm long PPRTA crystal by mixing two cw single-frequency Ti:Al2O3 lasers operating near 713 nm and 871 nm, respectively, using a laser pump power of 300 mW. A quasi-phase-matched infrared wavelength-tuning bandwidth (FWHM) of ~ 12 cm-1 and a temperature tuning rate of 1.02 cm-1/degree C were achieved. Experimental details regarding the feasibility of trace gas detection based on absorption spectroscopy of CO2 in ambient air using this DFG radiation source are also described.

NASA Discipline Life Sciences Technologies

Observations of Sea Surface Mean Square Slope During the Southern Ocean Waves Experiment

For the Southern Ocean Waves Experiment (SOWEX), conducted in June 1992 out of Hobart, Tasmania, the NASA Scanning Radar Altimeter (SRA) was shipped to Australia and installed on a CSIRO Fokker F-27 research aircraft instrumented to make comprehensive surface layer measurements of air-sea interaction fluxes. The SRA sweeps a radar beam of P (two-way) half-power width across the aircraft ground track over a swath equal to 0.8 of the aircraft height, simultaneously measuring the backscattered power at its 36 GHz (8.3 mm) operating frequency and the range to the sea surface at 64 cross-track positions. In realtime, the slant ranges are multiplied by the cosine of the off-nadir incidence angles (including the effect of aircraft roll attitude) to determine the vertical distances from the aircraft to the sea surface. These distances are subtracted from the aircraft height to produce a sea-surface elevation map, which is displayed on a monitor in the aircraft to enable real-time assessments of data quality and wave properties. The sea surface mean square slope (mss), which is predominantly caused by the short waves, was determined from the backscattered power falloff with incidence angle measured by the SRA in the plane normal to the aircraft heading. On each flight, data were acquired at 240 m altitude while the aircraft was in a 7 degree roll attitude, interrogating off-nadir incidence angles from -15 degrees through nadir to +29 degrees. The aircraft turned azimuthally through 810 degrees in this attitude, mapping the azimuthal dependence of the backscattered power falloff with incidence angle. Two sets of turning data were acquired on each day, before and after the aircraft measured wind stress at low altitude (12 meters to 65 meters). Wave topography and backscattered power for mss were also acquired during those level flight segments whenever the aircraft altitude was above the SRA minimum range of 35 m. Data were collected over a wide range of wind and sea conditions, from quiescent to gale force winds with 9 meter wave height.

Walsh, E. J.

The Timing Evolution of 4U 1630-47 During Its 1998 Outburst

We report on the evolution of the timing of 4U 1630-47 during its 1998 outburst using data obtained with the Rossi X-ray Timing Explorer (RXTE). The count rate and position in hardness intensity, color-color diagrams, and simple spectral fits are used to track the concurrent spectral changes. The source showed seven distinct types of timing behavior, most of which show differences with the canonical black hole spectral/timing states. In marked contrast to previous outbursts, we find quasi-periodic oscillation (QPO) signals during nearly all stages of the outburst with frequencies between 0.06 and 14 Hz and a remarkable variety of other characteristics. In particular, we find large (up to 23% rms) amplitude QPOs on the early rise. Later, slow 0.1 Hz semiregular short (-5 s), 9%-16% deep dips dominate the light curve. At this time there are two QPOs, one stable near 13.5 Hz and the other whose frequency drops from the 6-8 Hz range to -4.5 Hz during the dips. BeppoSAX observations during the very late declining phase show 4U 1630-47 in a low state.

Dieters, S. W.

Does the Inner Disk Boundary of a Black Hole X-Ray Binary move During an Outburst?

Comptonization in the corona of an X-ray binary may reduce significantly the flux in the observed soft component of its X-ray spectrum. There fore the apparent inner disk radius inferred from the observed soft component may change in accordance to the fraction of the disk emission scattered into the hard component. We have developed a simple numerical model for carrying out the radiative transfer correction, in order to determine the original disk emission before the Comptonization in the hot corona. Applying this model to the extensive monitoring data of several black hole X-ray binaries with RXTE, we have found that most of the previous 1 y reported inner disk radius variations may be explained as due to this radiative transfer effect in the corona. We thus conclude that there is currently no evidence for significant inner disk boundary movement during the outbursts of these black hole X-ray binaries we have studied with the RXTE data.: GROJ1655-40, XTEJ1550-564, XTEJ1748-288 and XTEJ2012+381.

Zhang, S. N.

Evolution of the Iron K-Alpha Emission Line in the Black Hole Candidate GX339-4 During and Outburst Decay Phase

The evolution of the iron K-alpha line emission feature was found from the black hole candidate GX339-4 when its X-ray flux (2 to 10 keV) decreased significantly. With RXTE observations, a broad line emission feature around 7 keV was detected in its quiescent and low flux state; while in the high flux state, an emission line feature around 6.4 keV was detected. A similar 6.4 keV line feature was also detected with previous ASCA observations in a high flux state. We consider that the evolution could be the evidence of the variations in the geometric structure and the physical properties of the accretion flow when the accretion rate changed. This is because that the 7 keV line feature can be produced by the radiative recombination cascade, collisional excitation, and fluorescence of Fe XXVI and Fe XXV, which can exist in a very high temperature plasma; while the 6.4 keV line feature can be produced by fluorescent K-alpha line emission of neutral iron atoms in the cold accretion disk. (copyright) 1999 American Astronomical Society. All rights reserved.

Feng, Y.

Observations of Sea Surface Mean Square Slope During the Southern Ocean Waves Experiment

For the Southern Ocean Waves Experiment (SOWEX), conducted in June 1992 out of Hobart, Tasmania, the 36 GHz (8.3 mm) NASA Scanning Radar Altimeter (SRA) was shipped to Australia and installed on a CSIRO Fokker F-27 research aircraft instrumented to make comprehensive surface layer measurements of air-sea interaction fluxes. The sea surface mean square slope (mss), which is predominantly caused by the short waves, was determined from the backscattered power falloff with incidence angle measured by the SRA in the plane normal to the aircraft heading. On each flight, data were acquired at 240 m altitude while the aircraft was in a 7 deg roll attitude, interrogating off-nadir incidence angles from -15 deg through nadir to +29 deg. The aircraft turned azimuthally through 810 deg in this attitude, mapping the azimuthal dependence of the backscattered power falloff with incidence angle. Two sets of turning data were acquired on each day, before and after the aircraft measured wind stress at low altitude (12 m to 65 m). Wave topography and backscattered power for mss were also acquired during those level flight segments whenever the aircraft altitude was above the SRA minimum range of 35 m. A unique feature of this experiment was the use of a nadir-directed low-gain horn antenna (35 deg beamwidth) to acquire azimuthally integrated backscattered power data versus incidence angle before and after the turn data.

Walsh, E. J.

Possible Detection of Pi(exp 0)-Decay Gamma-Ray Emission from Cyg OB2 by EGRET

We report possible detection of pi (exp 0) decay radiation from Cyg OB2, a nearby (1.7 kpc) massive OB star association. The EGRET flux (greater than 100 MeV) maps clearly indicate a point source whose error circle includes both Cyg OB2 and Cyg X-3. We show that Cyg X-3 is unlikely to be the counterpart for the EGRET source, because of the marginal spatial consistency and the lack of the 4.8 hour modulation seen in other high energy emissions from Cyg X-3. If confirmed, this will be the first detection by EGRET of massive stars.

Chen, W.

ASCA solid state imaging spectrometer observations of O stars

We report ASCA Solid State Imaging Spectrometer (SIS) x-ray observations of the O stars delta Ori and lambda Ori. The energy resolution of the SIS allows us to resolve features in the O star x-ray spectra which are not apparent in spectra obtained by x-ray spectrometers with lower energy resolution. SIS spectra from both stars show evidence of line emission, suggesting the thermal nature of the x-ray source. However, the observed line strengths are different for the two stars. The observed stellar x-ray spectra are not well described by isothermal models although absorbed thermal emission models with two or more temperatures can provide an adequate fit to the data. For both stars we present evidence of absorbing columns significantly larger than the known ISM columns, indicative of absorption by a circumstellar medium, presumably the stellar winds. In addition, the lambda Ori spectrum shows the presence of emission at energies greater than 3 keV which is not seen in the delta Ori spectrum.

Corcoran, M. F.

ASCA solid state imaging spectrometer observations of O stars

We report ASCA Solid State Imaging Spectrometer (SIS) X-ray observations of the O stars delta Ori and lambda Ori. The energy resolution of the SIS allows us to resolve features in the O star X-ray spectra which are not apparent in spectra obtained by X-ray spectrometers with lower energy resolution. SIS spectra from both stars show evidence of line emission, suggesting the thermal nature of the X-ray source. However, the observed line strengths are different for the two stars. The observed stellar X-ray spectra are not well described by isothermal models although absorbed thermal emission models with two or more temperatures can provide an adequate fit to the data. For both stars we present evidence of absorbing columns significantly larger than the known Interstellar Medium (ISM) columns, indicative of absorption by a circumstellar medium, presumably the stellar winds. In addition, the lambda Ori spectrum shows the presence of emission at energies greater than 3 keV which is not seen in the delta Ori spectrum.

Corcoran, M. F.

Purification, growth, and characterization of Zn(x)Cd(1-x)Se crystals

The purification of starting materials which were used in the growth of Zn(x)Cd(1-x)Se (x = 0.2) single crystals using the traveling solution method (TSM) is reported. Up to 13 cm long single crystals and as grown resistivities of 6 x 10(exp 12) ohm/cm could be achieved. Infrared and Raman spectra of Zn(0.2)Cd(0.8)Se are also presented and discussed.

Silberman, E.

On the cyclic stress-strain behaviour of a Ni-base superalloy at room temperature

The cyclic stress-strain behavior of Nimonic alloy PE16 was studied at room temperature and at different aging conditions to determine whether the plateau in the cyclic stress-strain curve (CSSC) reported by Arbuthnot (1982) is typical of the room temperature behavior and/or some specific initial microstructural states. Specimen blanks were heat-treated in batches in Ar/H2 (98/2) atmosphere to produce gamma-prime precipitates of different average sizes, but with the volume fraction of gamma-prime precipitates kept constant at about 7 percent at all the heat-treatment conditions. Total axial strain controlled LCF tests were conducted under fully reversed loading (R = -1) at a constant strain rate of 0.004/s, using a servohydraulic machine. The load response in tension and compression was recorded continually, and stress-strain hysteresis loops were recorded at frequent intervals. In the present investigation, the CSSCs of the P16 alloy at room temperature did not display the plateaus reported by Arbuthnot.

Singh, Vakil

Photon radiation effects on CdS/CuInSe2 thin film solar cells

The unknown tolerance of CuInSe2 cells to proton irradiation, was tested. It was shown that CdS/CuInSe2 solar cells have an inherent tolerance to irradiation by 1 MeV electrons up to at least 2 x 10 to the 16th power electrons/sq cm. Eleven, unencapsulated, 1 sq cm cells deposited on alumina substrates were irradiated with 1 MeV protons at normal incidence. The cells were exposed to six fluences ranging from 2.5 x 10 to the 10th power protons/sq cm to 5.0 x 10 to the 13th power protons/sq cm. After each interval of exposure, the cells were removed from the radiation chamber to undergo current/voltage characterization. It is shown that none of the cells electrical characteristics exhibited any degradation up to and including a fluence of 1 x 10 to the 11th power protons/sq cm. At fluences greater than this, the damage to the CuInSe2 cells V sub oc and fill factor (FF) was more severe than that exhibited by the Isc. The CuInSe2 cells proved to be approximately a factor of 50 more resistant to 1 MeV proton irradiation than silicon or gallium arsenide cells. Annealing of a CuInSe2 cell at 225 deg C for 6 minutes restored it to within 95% of its initial efficiency.

Dursch, H.

Theory for Eccentric and Misalined Annular Seals

Theory describes behavior of eccentric and angularly-misalined incompressible-fluid shaft seals. Direct and cross-coupled stiffness and damping coefficients expressed in terms of degree of eccentricity and coefficients of concentric system.

Jackson, E.

Spectroscopic characterization of titanium 6-4 surfaces after chemical pretreatments

Several techniques have been used to study pretreated Ti 6-4 surfaces including scanning electron microscopy (SEM), electron spectroscopy of chemical analysis (ESCA), and, reflectance visibile spectroscopy. Each pretreatment type gives a characteristic surface morphology as seen by SEM. Elemental analysis of the Ti 6-4 surfaces was done using ESCA. Trace residual contaminants from particular chemical pretreatments are identified readily. Reflectance visible spectroscopy using indicator dyes placed on Ti 6-4 surfaces appears to be a feasible approach to establish surface acidity. Differences in surface acidity have been observed using bromthymol blue on Ti 6-4 surfaces pretreated by two different methods.

Chen, W.

A fundamental approach to adhesion: Synthesis, surface analysis, thermodynamics and mechanics

Adherend surfaces and fractography were studied using electron spectroscopy for chemical analysis and scanning electron microscopy/energy dispersive analysis of X-rays. In addition, Auger Electron Spectroscopy with depth profiling capability was used. It is shown that contamination of adhesion systems plays an important role not only in determining initial bond strengths but also in the durability of adhesive bonds. It is concluded that the analytical techniques used to characterize and monitor such contamination.

Chen, W.

A fundamental approach to adhesion: Synthesis, surface analysis, thermodynamics and mechanics

Various surface preparations for titanium 6-4 alloy were studied. An anodizing method was investigated, and compared with the results of other chemical treatments, namely, phosphate/fluoride, Pasa-Jell and Turco. The relative durability of the different surface treatments was assessed by monitoring changes in surface chemistry and morphology occasioned by aging at 505 K (450 F). Basic electron spectroscopic data were collected for polyimide and polyphenylquinoxaline adhesives and synthetic precursors. Fractographic studies were completed for several combinations of adherend, adhesive, and testing conditions.

Chen, W.

Arterial pulse wave pressure transducer

An arterial pulse wave pressure transducer is introduced. The transducer is comprised of a fluid filled cavity having a flexible membrane disposed over the cavity and adapted to be placed on the skin over an artery. An arterial pulse wave creates pressure pulses in the fluid which are transduced, by a pressure sensitive transistor in direct contact with the fluid, into an electric signal. The electrical signal is representative of the pulse waves and can be recorded so as to monitor changes in the elasticity of the arterial walls.

Kim, C.

An economical arterial-pulse-wave transducer

Transducer records arterial pulses externally. Device uses thin plastic membrane which is fluid coupled to pressure sensitive transistor. Transistor is connected to amplifier which, in turn, is connected to recorder. End section is threaded to accept suitable holder and contains pressure relief vent allowing transistor to sense only pressure levels greater than atmospheric.

Kim, C.