Search NASA⌕ Search

Engineering topics

Chen, Wenshu

Publications and source records attributed to Chen, Wenshu.

Modeling Cell Survival Fraction and Other Dose-Response Relationships for Immunodeficient C.B-17 SCID Mice Exposed to 320-kV X Rays

US homeland security concerns related to potential misuse of γ-ray-emitting radiation sources employed in radiobiological research (eg, shielded cesium-137 irradiators) led to recommendations by the National Research Council to conduct studies into possibly replacing γ-ray irradiators used in research involving small rodent and other models with X-ray instruments. A limiting factor is suitability of the X-ray photon energy spectra. The objective of our research was to demonstrate the suitability of the radiation energy spectrum of 320-kV X rays after filtration (HVL = 4 mm Cu) for in-vivo cytotoxicity studies in immunodeficient C.B-17 SCID mice. By using a previously-published Hazard Function (HF) model to characterize dose-response relationships for in vivo bone marrow and spleen cell survival fractions and also to characterize the acute lethality risk (hematopoietic syndrome mode) we demonstrate that the filtered 320-kV X-ray beam appears suitable for such studies. A key finding for C.B-17 SCID mice when compared to results previously obtained for immunocompetent C.B-17 mice is that the immunodeficient mice appear to be more radioresistant, implicating a possible role of the immune system capacity in radiosensitivity of mammals.

Scott, Bobby R.↗

Radiobiological Studies Using Cs-137 Gamma or 320 kV X Rays

There are numerous self-shielded research irradiators used in various facilities throughout the United States. The irradiators employ radioactive sources containing either 137 Cs or 60 Co and the irradiators are used for a variety of radiobiological investigations involving cellular and/or animal models. A report from the National Academy of Sciences described security issues associated with particular radiation sources and the desire for their replacement with suitable X-ray irradiators. One possible replacement would be a 320 kV X-ray irradiator. The participants in this research successfully performed in vivo radiobiological studies involving mice exposed to filtered (HVL ≈ 4 mm Cu) 320 kV X rays. Two publications (one published and one submitted at the publishing of this report) documenting key findings are provided in Appendices A and B of this report. The 320 kV X rays were found suitable for in vivo (in mice) cell survival studies and are expected to be suitable for bone marrow transplantation studies using mice but this needs to be experimentally validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗