Search NASA⌕ Search

Engineering topics

Chen, Y. M.

Publications and source records attributed to Chen, Y. M..

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron irradiation and electrical characterisation of the first 8” silicon pad sensor prototypes for the CMS calorimeter endcap upgrade

As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures.The results on the electrical properties of the irradiated CE silicon sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test beam study of SiPM-on-tile configurations

Light yield and spatial uniformity for a large variety of configurations of scintillator tiles were studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique). The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model. Furthermore, these studies were performed using 120 GeV protons at the Fermilab Test Beam Facility. External tracking allowed the position of each proton penetrating a tile to be measured. The results were compared to a GEANT4 simulation of each configuration of scinitillator, wrapping, and SiPM.

47 OTHER INSTRUMENTATION↗

Construction and commissioning of CMS CE prototype silicon modules

As part of its HL-LHC upgrade program, the CMS collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CEE) and hadronic (CE-H) compartments. The calorimeter will be built with ~30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1 cm 2 , and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.

Calorimeters↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Melatonin and cortisol assessment of circadian shifts in astronauts before flight

Melatonin and cortisol were measured in saliva and urine samples to assess the effectiveness of a 7-day protocol combining bright-light exposure with sleep shifting in eliciting a 12-hr phase-shift delay in eight U.S. Space Shuttle astronauts before launch. Baseline acrophases for 15 control subjects with normal sleep-wake cycles were as follows: cortisol (saliva) at 0700 (0730 in urine); melatonin (saliva) at 0130 (6-hydroxymelatonin sulfate at 0230 in urine). Acrophases of the astronaut group fell within 2.5 hr of these values before the treatment protocols were begun. During the bright-light and sleep-shifting treatments, both absolute melatonin production and melatonin rhythmicity were diminished during the first 3 treatment days; total daily cortisol levels remained constant throughout the treatment. By the fourth to sixth day of the 7-day protocol, seven of the eight crew members showed phase delays in all four measures that fell within 2 hr of the expected 11- to 12-hr shift. Although cortisol and melatonin rhythms each corresponded with the phase shift, the rhythms in these two hormones did not correspond with each other during the transition.

NASA Center JSC↗

Human cardiovascular response to sympathomimetic agents during head-down bed rest: the effect of dietary sodium

Changes in sympathoadrenal function and cardiovascular deconditioning have long been recognized as a feature of the physiological adaptation to microgravity. The deconditioning process, coupled with altered hydration status, is thought to significantly contribute to orthostatic intolerance upon return to Earth gravity. The cardiovascular response to stimulation by sympathomimetic agents before, during, and after exposure to simulated microgravity was determined in healthy volunteers equilibrated on normal or high sodium diets in order to further the understanding of the deconditioning process.

NASA Discipline Number 18-10↗

Atrial natriuretic peptide degradation by CPA47 cells - Evidence for a divalent cation-independent cell-surface proteolytic activity

Atrial natriuretic peptide (ANP) is rapidly cleared and degraded in vivo. Nonguanylate-cyclase receptors (C-ANPR) and a metalloproteinase, neutral endopeptidase (EC 3.4.24.11) (NEP 24.11), are thought to be responsible for its metabolism. We investigated the mechanisms of ANP degradation by an endothelial-derived cell line, CPA47. CPA47 cells degraded 88 percent of 125I-ANP after 1 h at 37 degrees C as determined by HPLC. Medium preconditioned by these cells degraded 41 percent of the 125I-ANP, and this activity was inhibited by a divalent cation chelator, EDTA. Furthermore, a cell-surface proteolytic activity degraded 125I-ANP in the presence of EDTA when receptor-mediated endocytosis was inhibited either by low temperature (4 degrees C) or by hyperosmolarity at 37 degrees C. The metalloproteinase, NEP 24.11, is unlikely to be the cell-surface peptidase because 125I-ANP is degraded by CPA47 cells at 4 degrees C in the presence of 5 mM EDTA. These data indicate that CPA47 cells can degrade ANP by a novel divalent cation-independent cell-surface proteolytic activity.

Frost, S. J.↗

Application of a novel finite difference method to dynamic crack problems

A versatile finite difference method (HEMP and HEMP 3D computer programs) was developed originally for solving dynamic problems in continuum mechanics. It was extended to analyze the stress field around cracks in a solid with finite geometry subjected to dynamic loads and to simulate numerically the dynamic fracture phenomena with success. This method is an explicit finite difference method applied to the Lagrangian formulation of the equations of continuum mechanics in two and three space dimensions and time. The calculational grid moves with the material and in this way it gives a more detailed description of the physics of the problem than the Eulerian formulation.

Chen, Y. M.↗