Search for GeV-scale dark matter from the Galactic Center with IceCube-DeepCore

Models describing dark matter as a novel particle often predict that its annihilation or decay into Standard Model particles could produce a detectable neutrino flux in regions of high dark matter density, such as the Galactic Center. In this work, we search for these neutrinos using ∼9 years of IceCube-DeepCore data with an event selection optimized for energies between 15 to 200 GeV. We considered several annihilation and decay channels and dark matter masses ranging from 15 GeV up to 8 TeV. No significant deviation from the background expectation from atmospheric neutrinos and muons was found. The most significant result was found for a dark matter mass of 201.6 GeV annihilating into a pair of bb¯ quarks assuming the Navarro–Frenk–White halo profile with a post-trial significance of 1.08σ. We present upper limits on the thermally averaged annihilation cross section of the order of 10-24 cm3 s-1, as well as lower limits on the dark matter decay lifetime up to 1026 s for dark matter masses between 5 GeV up to 8 TeV. These results strengthen the current IceCube limits on dark matter masses above 20 GeV and provide an order of magnitude improvement at lower masses. In addition, they represent the strongest constraints from any neutrino telescope on GeV-scale dark matter and are among the world-leading limits for several dark matter scenarios.

Abbasi, R↗

Identification and denoising of radio signals from cosmic-ray air showers using convolutional neural networks

Radio pulses generated by cosmic-ray air showers can be used to reconstruct key properties like the energy and depth of the electromagnetic component of cosmic-ray air showers. Radio detection threshold, influenced by natural and anthropogenic radio background, can be reduced through various techniques. In this work, we demonstrate that convolutional neural networks (CNNs) are an effective way to lower the threshold. We developed two CNNs: a classifier to distinguish radio signal waveforms from background noise and a denoiser to clean contaminated radio signals. Following the training and testing phases, we applied the networks to air-shower data triggered by scintillation detectors of the prototype station for the enhancement of IceTop, IceCube’s surface array at the South Pole. Over a four-month period, we identified 554 cosmic-ray events in coincidence with IceTop, approximately five times more compared to a reference method based on a cut on the signal-to-noise ratio. Comparisons with IceTop measurements of the same air showers confirmed that the CNNs reliably identified cosmic-ray radio pulses and outperformed the reference method. Additionally, we find that CNNs reduce the false-positive rate of air-shower candidates and effectively denoise radio waveforms, thereby improving the accuracy of the power and arrival time reconstruction of radio pulses.

Abbasi, R↗

Measurement of the inelasticity distribution of neutrino-nucleon interactions for 80 GeV

We report a study of the inelasticity distribution in the scattering of neutrinos of energy 80–560 GeV off nucleons. Using atmospheric muon neutrinos detected in IceCube’s sub-array DeepCore during 2012–2021, we fit the observed inelasticity in the data to a parameterized expectation and extract the values that describe it best. Finally, we compare the results to predictions from various combinations of perturbative QCD calculations and atmospheric neutrino flux models.

Abbasi, R↗

Search for dark matter from the center of the Earth with 10 years of IceCube data

The nature of dark matter remains unresolved in fundamental physics. Weakly Interacting Massive Particles (WIMPs), which could explain the nature of dark matter, can be captured by celestial bodies like the Sun or Earth, leading to enhanced self-annihilation into Standard Model particles including neutrinos detectable by neutrino telescopes such as the IceCube Neutrino Observatory. This article presents a search for muon neutrinos from the center of the Earth performed with 10 years of IceCube data using a track-like event selection. We considered a number of WIMP annihilation channels (χχ→τ+τ-$$\chi \chi \rightarrow \tau ^+\tau ^-$$/W+W-$$W^+W^-$$/bb¯$$b\bar{b}$$) and masses ranging from 10 GeV to 10 TeV. No significant excess over background due to a dark matter signal was found while the most significant result corresponds to the annihilation channel χχ→bb¯$$\chi \chi \rightarrow b\bar{b}$$ for the mass mχ=250$$m_{\chi }=250$$ GeV with a post-trial significance of 1.06σ$$1.06\sigma $$. Our results are competitive with previous such searches and direct detection experiments. Our upper limits on the spin-independent WIMP scattering are world-leading among neutrino telescopes for WIMP masses mχ>100$$m_{\chi }>100$$ GeV.

Abbasi, R↗

Search for an eV-Scale Sterile Neutrino Using Improved High-Energy νμ Event Reconstruction in IceCube

This Letter presents the result of a 3+1 sterile neutrino search using 10.7 yr of IceCube data. We analyze atmospheric muon neutrinos that traverse the Earth with energies ranging from 0.5 to 100 TeV, incorporating significant improvements in modeling neutrino flux and detector response compared to earlier studies. Notably, for the first time, we categorize data into starting and throughgoing events, distinguishing neutrino interactions with vertices inside or outside the instrumented volume, to improve energy resolution. The best-fit point for a 3+1 model is found to be at sin^{2}(2θ_{24})=0.16 and Δm_{41}^{2}=3.5 eV^{2}, which agrees with previous iterations of this Letter. The result is consistent with the null hypothesis of no sterile neutrinos with a p value of 3.1%.

Neutrino detection↗

Searching for High-energy Neutrino Emission from Galaxy Clusters with IceCube

Galaxy clusters have the potential to accelerate cosmic rays (CRs) to ultrahigh energies via accretion shocks or embedded CR acceleration sites. The CRs with energies below the Hillas condition will be confined within the cluster and eventually interact with the intracluster medium gas to produce secondary neutrinos and gamma rays. Using 9.5 yr of muon neutrino track events from the IceCube Neutrino Observatory, we report the results of a stacking analysis of 1094 galaxy clusters with masses ≳10 14 M ⊙ and redshifts between 0.01 and ~1 detected by the Planck mission via the Sunyaev–Zel’dovich effect. We find no evidence for significant neutrino emission and report upper limits on the cumulative unresolved neutrino flux from massive galaxy clusters after accounting for the completeness of the catalog up to a redshift of 2, assuming three different weighting scenarios for the stacking and three different power-law spectra. Weighting the sources according to mass and distance, we set upper limits at a 90% confidence level that constrain the flux of neutrinos from massive galaxy clusters (≳10 14 M ⊙ ) to be no more than 4.6% of the diffuse IceCube observations at 100 TeV, assuming an unbroken E -2.5 power-law spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Increasing Baselines and Precision of Optical Interferometers Using Two-Photon Interference

Observations using interferometers provide sensitivity to features of images on angular scales much smaller than any single telescope, on the order of Δθ ~ λ/b where b is the interferometric baseline. Present-day optical interferometers are essentially classical, interfering single photons with themselves. However, there is a new wave of interest in interferometry using multiple photons, whose mechanisms are inherently quantum mechanical, which offer the prospects of increased baselines and finer resolutions among other advantages. We will discuss recent ideas and results for quantum-assisted interferometry using the resource of entangled pairs, and specifically a two-photon amplitude technique aimed at improved precision in astrometry.

47 OTHER INSTRUMENTATION↗

SU-D-202-04: Validation of Deformable Image Registration Algorithms for Head and Neck Adaptive Radiotherapy in Routine Clinical Setting

Purpose: To evaluate the ROI contours and accumulated dose difference using different deformable image registration (DIR) algorithms for head and neck (H&N) adaptive radiotherapy. Methods: Eight H&N cancer patients were randomly selected from the affiliated hospital. During the treatment, patients were rescanned every week with ROIs well delineated by radiation oncologist on each weekly CT. New weekly treatment plans were also re-designed with consistent dose prescription on the rescanned CT and executed for one week on Siemens CT-on-rails accelerator. At the end, we got six weekly CT scans from CT1 to CT6 including six weekly treatment plans for each patient. The primary CT1 was set as the reference CT for DIR proceeding with the left five weekly CTs using ANACONDA and MORFEUS algorithms separately in RayStation and the external skin ROI was set to be the controlling ROI both. The entire calculated weekly dose were deformed and accumulated on corresponding reference CT1 according to the deformation vector field (DVFs) generated by the two different DIR algorithms respectively. Thus we got both the ANACONDA-based and MORFEUS-based accumulated total dose on CT1 for each patient. At the same time, we mapped the ROIs on CT1 to generate the corresponding ROIs on CT6 using ANACONDA and MORFEUS DIR algorithms. DICE coefficients between the DIR deformed and radiation oncologist delineated ROIs on CT6 were calculated. Results: For DIR accumulated dose, PTV D95 and Left-Eyeball Dmax show significant differences with 67.13 cGy and 109.29 cGy respectively (Table1). For DIR mapped ROIs, PTV, Spinal cord and Left-Optic nerve show difference with −0.025, −0.127 and −0.124 (Table2). Conclusion: Even two excellent DIR algorithms can give divergent results for ROI deformation and dose accumulation. As more and more TPS get DIR module integrated, there is an urgent need to realize the potential risk using DIR in clinical.

60 APPLIED LIFE SCIENCES↗

SU-F-I-08: CT Image Ring Artifact Reduction Based On Prior Image

Purpose: In computed tomography (CT) system, CT images with ring artifacts will be reconstructed when some adjacent bins of detector don’t work. The ring artifacts severely degrade CT image quality. We present a useful CT ring artifacts reduction based on projection data correction, aiming at estimating the missing data of projection data accurately, thus removing the ring artifacts of CT images. Methods: The method consists of ten steps: 1) Identification of abnormal pixel line in projection sinogram; 2) Linear interpolation within the pixel line of projection sinogram; 3) FBP reconstruction using interpolated projection data; 4) Filtering FBP image using mean filter; 5) Forwarding projection of filtered FBP image; 6) Subtraction forwarded projection from original projection; 7) Linear interpolation of abnormal pixel line area in the subtraction projection; 8) Adding the interpolated subtraction projection on the forwarded projection; 9) FBP reconstruction using corrected projection data; 10) Return to step 4 until the pre-set iteration number is reached. The method is validated on simulated and real data to restore missing projection data and reconstruct ring artifact-free CT images. Results: We have studied impact of amount of dead bins of CT detector on the accuracy of missing data estimation in projection sinogram. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, three iterations are sufficient to restore projection data and reconstruct ring artifact-free images when the dead bins rating is under 30%. The dead-bin-induced artifacts are substantially reduced. More iteration number is needed to reconstruct satisfactory images while the rating of dead bins increases. Similar results were found for a real head phantom case. Conclusion: A practical CT image ring artifact correction scheme based on projection data is developed. This method can produce ring artifact-free CT images feasibly and effectively.

60 APPLIED LIFE SCIENCES↗

SU-F-T-199: A New Strategy for Integrating Photon with Proton and Carbon Ion in the Treatment Planning

Purpose: The aim of this study was to develop a viable strategy to integrate photon plan and proton/carbon ion plan based on deformable registration. Methods: Two prostate cancer patients were enrolled in this study. Each patient has 2 CTs, which were input in the Raystation radiotherapy treatment planning system (TPS). CT1 was deformed to the second CT2 using the Hybrid deformation method. The dice similarity coefficient (DSC) parameter was used to evaluate the difference between the actual structures (bladder, rectum and CTV) and the corresponding deformed structures on CT2. The prescription dose was 63.02GyE to CTV, which included 49.32GyE for CTV1 with carbon and boost 13.7Gy for CTV2 with photon. The carbon plan was made first in Syngo TPS (Syngo PT Planning system, version VB10. Siemens, Germany) on CT1 and transferred to Raystation TPS. Selected Isodoses (23.5Gy, 36.8Gy, 39.1Gy, 47.0Gy and 49.3Gy) of carbon plan were converted to contours and then deformed to CT2, which was used as normal tissues for photon plan optimization on CT2. The final plan was the combination of photon plan and the carbon deformation plan on the CT2. The plan from this strategy was compared with direct optimization of the photon plan on CT2 added some clinical endpoints from carbon plan on CT1. Results: The new strategy with deformable registration is tested and combined plans were successfully obtained for the 2 patients. This strategy obtained both integrated DVH and dose distribution information. For patient 1, the rectum V30, V60 and bladder V63 were 45.8, 10.3 and 9.7 for the combined plan with deformation and 48.1, 11.0 and 12.0 for the direct photon plan. Conclusion: The new strategy for combining photon and carbon/proton is feasible. However, the clinical accuracy is still need more evaluation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

60 APPLIED LIFE SCIENCES↗

SU-F-T-348: The Impact of Model Library Population On RapidPlan Based Dose-Volume Histograms (DVHs) Prediction for Rectal Cancer Patients Treated with Volumetric-Modulated Radiotherapy (VMAT)

Purpose: RapidPlan uses a library consisting of expert plans from different patients to create a model that can predict achievable dose-volume histograms (DVHs) for new patients. The goal of this study is to investigate the impacts of model library population (plan numbers) on the DVH prediction for rectal cancer patients treated with volumetric-modulated radiotherapy (VMAT) Methods: Ninety clinically accepted rectal cancer patients’ VMAT plans were selected to establish 3 models, named as Model30, Model60 and Model90, with 30,60, and 90 plans in the model training. All plans had sufficient target coverage and bladder and femora sparings. Additional 10 patients were enrolled to test the DVH prediction differences with these 3 models. The predicted DVHs from these 3 models were compared and analyzed. Results: Predicted V40 (Vx, percent of volume that received x Gy for the organs at risk) and Dmean (mean dose, cGy) of the bladder were 39.84±13.38 and 2029.4±141.6 for the Model30,37.52±16.00 and 2012.5±152.2 for the Model60, and 36.33±18.35 and 2066.5±174.3 for the Model90. Predicted V30 and Dmean of the left femur were 23.33±9.96 and 1443.3±114.5 for the Model30, 21.83±5.75 and 1436.6±61.9 for the Model60, and 20.31±4.6 and 1415.0±52.4 for the Model90.There were no significant differences among the 3 models for the bladder and left femur predictions. Predicted V40 and Dmean of the right femur were 19.86±10.00 and 1403.6±115.6 (Model30),18.97±6.19 and 1401.9±68.78 (Model60), and 21.08±7.82 and 1424.0±85.3 (Model90). Although a slight lower DVH prediction of the right femur was found on the Model60, the mean differences for V30 and mean dose were less than 2% and 1%, respectively. Conclusion: There were no significant differences among Model30, Model60 and Model90 for predicting DVHs on rectal patients treated with VMAT. The impact of plan numbers for model library might be limited for cancers with similar target shape.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-09: Estimation of Motion Tracking Uncertainty for Real-Time Adaptive Imaging

Purpose: kV fluoroscopic imaging combined with MV treatment beam imaging has been investigated for intrafractional motion monitoring and correction. It is, however, subject to additional kV imaging dose to normal tissue. To balance tracking accuracy and imaging dose, we previously proposed an adaptive imaging strategy to dynamically decide future imaging type and moments based on motion tracking uncertainty. kV imaging may be used continuously for maximal accuracy or only when the position uncertainty (probability of out of threshold) is high if a preset imaging dose limit is considered. In this work, we propose more accurate methods to estimate tracking uncertainty through analyzing acquired data in real-time. Methods: We simulated motion tracking process based on a previously developed imaging framework (MV + initial seconds of kV imaging) using real-time breathing data from 42 patients. Motion tracking errors for each time point were collected together with the time point’s corresponding features, such as tumor motion speed and 2D tracking error of previous time points, etc. We tested three methods for error uncertainty estimation based on the features: conditional probability distribution, logistic regression modeling, and support vector machine (SVM) classification to detect errors exceeding a threshold. Results: For conditional probability distribution, polynomial regressions on three features (previous tracking error, prediction quality, and cosine of the angle between the trajectory and the treatment beam) showed strong correlation with the variation (uncertainty) of the mean 3D tracking error and its standard deviation: R-square = 0.94 and 0.90, respectively. The logistic regression and SVM classification successfully identified about 95% of tracking errors exceeding 2.5mm threshold. Conclusion: The proposed methods can reliably estimate the motion tracking uncertainty in real-time, which can be used to guide adaptive additional imaging to confirm the tumor is within the margin or initialize motion compensation if it is out of the margin.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-11: Sparse-View CT Reconstruction Via a Novel Non-Local Means Method

Purpose: Sparse-view computed tomography (CT) reconstruction is an effective strategy to reduce the radiation dose delivered to patients. Due to its insufficiency of measurements, traditional non-local means (NLM) based reconstruction methods often lead to over-smoothness in image edges. To address this problem, an adaptive NLM reconstruction method based on rotational invariance (RIANLM) is proposed. Methods: The method consists of four steps: 1) Initializing parameters; 2) Algebraic reconstruction technique (ART) reconstruction using raw projection data; 3) Positivity constraint of the image reconstructed by ART; 4) Update reconstructed image by using RIANLM filtering. In RIANLM, a novel similarity metric that is rotational invariance is proposed and used to calculate the distance between two patches. In this way, any patch with similar structure but different orientation to the reference patch would win a relatively large weight to avoid over-smoothed image. Moreover, the parameter h in RIANLM which controls the decay of the weights is adaptive to avoid over-smoothness, while it in NLM is not adaptive during the whole reconstruction process. The proposed method is named as ART-RIANLM and validated on Shepp-Logan phantom and clinical projection data. Results: In our experiments, the searching neighborhood size is set to 15 by 15 and the similarity window is set to 3 by 3. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, the ART-RIANLM produces higher SNR (35.38dB<24.00dB) and lower MAE (0.0006<0.0023) reconstructed image than ART-NLM. The visual inspection demonstrated that the proposed method could suppress artifacts or noises more effectively and preserve image edges better. Similar results were found for clinical data case. Conclusion: A novel ART-RIANLM method for sparse-view CT reconstruction is presented with superior image. Compared to the conventional ART-NLM method, the SNR and MAE from ART-RIANLM increases 47% and decreases 74%, respectively.

60 APPLIED LIFE SCIENCES↗

TU-D-209-07: Monte Carlo Assessment of Dose to the Lens of the Eye of Radiologist Using Realistic Phantoms and Eyeglass Models

Purpose: To study how eyeglass design features and postures of the interventional radiologist affect the radiation dose to the lens of the eye. Methods: A mesh-based deformable phantom, consisting of an ultra-fine eye model, was used to simulate postures of a radiologist in fluoroscopically guided interventional procedure (facing the patient, 45 degree to the left, and 45 degree to the right). Various eyewear design features were studied, including the shape, lead-equivalent thickness, and separation from the face. The MCNPX Monte Carlo code was used to simulate the X-ray source used for the transcatheter arterial chemoembolization procedure (The X-ray tube is located 35 cm from the ground, emitting X-rays toward to the ceiling; Field size is 40cm X 40cm; X-ray tube voltage is 90 kVp). Experiments were also performed using dosimeter placed on a physical phantom behind eyeglasses. Results: Without protective eyewear, the radiologist’s eye lens can receive an annual dose equivalent of about 80 mSv. When wearing a pair of lead eyeglasses with lead-equivalent of 0.5-mm Pb, the annual dose equivalent of the eye lens is reduced to 31.47 mSv, but both exceed the new ICRP limit of 20 mSv. A face shield with a lead-equivalent of 0.125-mm Pb in the shape of a semi-cylinder (13cm in radius and 20-cm in height) would further reduce the exposure to the lens of the eye. Examination of postures and eyeglass features reveal surprising information, including that the glass-to-eye separation also plays an important role in the dose to the eye lens from scattered X-ray from underneath and the side. Results are in general agreement with measurements. Conclusion: There is an urgent need to further understand the relationship between the radiation environment and the radiologist’s eyewear and posture in order to provide necessary protection to the interventional radiologists under newly reduced dose limits.

60 APPLIED LIFE SCIENCES↗