Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leveraging Open-Source Tools for Collaborative Macro-energy System Modeling Efforts

The authors are founding team members of a new effort to develop an Open Energy Outlook for the United States. The effort aims to apply best practices of policy-focused energy system modeling, ensure transparency, build a networked community, and work toward a common purpose: examining possible US energy system futures to inform energy and climate policy efforts. Individual author biographies can be found on the project website: https://openenergyoutlook.org/.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methodology for energy strategy to prescreen the feasibility of Ground Source Heat Pump systems in residential and commercial buildings in the United States

Geothermal resources have potential to reduce dependence on fossil fuels. The viability of geothermal heat pumps or ground source heat pumps (GSHPs) is significant as a potential alternative energy source with substantial savings potential. While the prospect of these systems is promising for energy efficiency, careful feasibility analysis is required before implementation. Here, this paper presents the results of evaluation of the application feasibility for GSHPs in buildings across seven climate zones in three United States regions. A comprehensive methodology is developed to measure the integrated feasibility of GSHPs using compiled data for energy use intensity, energy cost and design parameters. Four different feasibility metrics are utilized: ground temperature, outdoor weather condition, energy savings potential, and cost benefits. For each metric, a corresponding feasibility score system is developed. The defined integrated feasibility score classifies the locations into five different feasibility levels ranging from Fair (0–20), Moderate (21–40), Good (41–60), High (61–80), and Very High (81–100). Conclusions show the GSHP feasibility level is High for 3 sites, Good for 8 sites and Moderate for 4 sites. Through the methodology, it is possible to develop a practical energy strategy for more economic and sustainable GSHP systems at an early design stage in the various viewpoints of geometries, climate conditions, operational factors, and energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application priority of GSHP systems in the climate conditions of the United States

Building energy-performance simulation programs are powerful tools for many aspects of feasibility studies regarding ground source heat pump (GSHP). However, the understanding of the limitations of the energy modelling programs, their capability of predicting energy performance early in the design process, and the complicated functionality of these programs makes the software programs harder to use and less practical. The interactive tool developed in this study seeks to provide analysis information in a straightforward manner that is inexpensive, convenient, and sophisticated. This tool uses an inclusive approach to assess the feasibility of GSHPs by prescreening critical factors such as climate conditions, ground temperatures, energy use, and cost savings. It is interactive and enables the user to do a feasibility analysis with a weighting factor for each feasibility criterion based on the user’s preference and interests. The application of the tool explains feasibility scores of 15 representative cities in various climatic conditions across the US. Results for commercial buildings show that the GSHP systems are more feasible in cold and dry, cool and humid, and very cold areas than warm and dry, very hot and humid, and mixed marine areas, and that most feasibility levels are located on good and moderate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗