Search NASA⌕ Search

Engineering topics

Chodankar, Shirish

Publications and source records attributed to Chodankar, Shirish.

Investigating the quaternary structure of a homomultimeric catechol 1,2-dioxygenase: An integrative structural biology study

The structural analysis of catechol 1,2 dioxygenase from Stutzerimonas frequens GOM2, SfC12DO, was conducted using various structural techniques. SEC-SAXS experiments revealed that SfC12DO, after lyophilization and reconstitution processes, can form multiple enzymatically active oligomers, including dimers, tetramers, and octamers. These findings differ from previous studies, which reported active dimers in homologous counterparts with available crystallographic structures, or trimers observed exclusively in solution for SfC12DO and its homologous isoA C12DO from Acinetobacter radioresistens under low ionic strength conditions. In some cases, tetramers were also reported, such as for the Rodococcus erythropolis C12DO. The combined results of Small-Angle X-ray Scattering, Dynamic Light Scattering, and Transmission Electron Microscopy experiments provided additional insights into these active oligomers’ shape and molecular organization in an aqueous solution. These results highlight the oligomeric structural plasticity of SfC12DO, proving that it can exist in different oligomeric forms depending on the physicochemical characteristics of the solutions in which the experiments were performed. Remarkably, regardless of its oligomeric state, SfC12DO maintains its enzymatic activity even after prior lyophilization. All these characteristics make SfC12DO a putative candidate for bioremediation applications in polluted soils or waters.

59 BASIC BIOLOGICAL SCIENCES↗

Solvent-Dependent Dynamics of Cellulose Nanocrystals in Process-Relevant Flow Fields

Flow-assisted alignment of anisotropic nanoparticles is a promising route for the bottom-up assembly of advanced materials with tunable properties. While aligning processes could be optimized by controlling factors such as solvent viscosity, flow deformation, and the structure of the particles themselves, it is necessary to understand the relationship between these factors and their effect on the final orientation. In this study, we investigated the flow of surface-charged cellulose nanocrystals (CNCs) with the shape of a rigid rod dispersed in water and propylene glycol (PG) in an isotropic tactoid state. In situ scanning small-angle X-ray scattering (SAXS) and rheo-optical flow-stop experiments were used to quantify the dynamics, orientation, and structure of the assigned system at the nanometer scale. The effects of both shear and extensional flow fields were revealed in a single experiment by using a flow-focusing channel geometry, which was used as a model flow for nanomaterial assembly. Due to the higher solvent viscosity, CNCs in PG showed much slower Brownian dynamics than CNCs in water and thus could be aligned at lower deformation rates. Moreover, CNCs in PG also formed a characteristic tactoid structure but with less ordering than CNCs in water owing to weaker electrostatic interactions. The results indicate that CNCs in water stay assembled in the mesoscale structure at moderate deformation rates but are broken up at higher flow rates, enhancing rotary diffusion and leading to lower overall alignment. Albeit being a study of cellulose nanoparticles, the fundamental interplay between imposed flow fields, Brownian motion, and electrostatic interactions likely apply to many other anisotropic colloidal systems.

36 MATERIALS SCIENCE↗

In situ synchrotron X-ray total scattering measurements and analysis of colloidal CsPbX 3 nanocrystals during flow synthesis

In situ X-ray scattering measurements of CsPbX 3 (X = Cl, Br, I) nanocrystal formation and halide exchange at NSLS-II beamlines were performed in an automated flow reactor. Total scattering measurements were performed at the 28-ID-2 (XPD) beamline and small-angle X-ray scattering at the 16-ID (LiX) beamline. Nanocrystal structural parameters of interest, including size, size distribution and atomic structure, were extracted from modeling the total scattering data. The results highlight the potential of these beamlines and the measurement protocols described in this study for studying dynamic processes of colloidal nanocrystal synthesis in solution with timescales on the order of seconds.

nucleation↗

Molecular basis of crosstalk in nuclear receptors: heterodimerization between PXR and CAR and the implication in gene regulation

The 48 human nuclear receptors (NRs) form a superfamily of transcription factors that regulate major physiological and pathological processes. Emerging evidence suggests that NR crosstalk can fundamentally change our understanding of NR biology, but detailed molecular mechanisms of crosstalk are lacking. Here, we report the molecular basis of crosstalk between the pregnane X receptor (PXR) and constitutive androstane receptor (CAR), where they form a novel heterodimer, resulting in their mutual inhibition. PXR and CAR regulate drug metabolism and energy metabolism. Although they have been broadly perceived as functionally redundant, a growing number of reports suggests a mutual inhibitory relation, but their precise mode of coordinated action remains unknown. Using methods including RNA sequencing, small-angle X-ray scattering and crosslinking mass spectrometry we demonstrate that the mutual inhibition altered gene expression globally and is attributed to the novel PXR–CAR heterodimerization via the same interface used by each receptor to heterodimerize with its functional partner, retinoid X receptor (RXR). These findings establish an unexpected functional relation between PXR, CAR and RXR, change the perceived functional relation between PXR and CAR, open new perspectives on elucidating their role and designing approaches to regulate them, and highlight the importance to comprehensively investigate nuclear receptor crosstalk.

59 BASIC BIOLOGICAL SCIENCES↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

Unraveling the Early-Stage Ordering of Krypton Solid Bubbles in Molybdenum: A Multimodal Study

Self-organization of defects such as fission gas bubbles in materials can lead to high inventory capacity for fission gas storage and help mitigate swelling caused by fission gases in nuclear fuel materials under radiation in nuclear reactors. Here, we report the physical mechanism of self-organization of krypton (Kr) gas bubbles in molybdenum (Mo) under ion implantation. The ion fluence and temperature-dependent formation of Kr solid bubble superlattice (SBS) in Mo were investigated by using both synchrotron-based small-angle X-ray scattering (SAXS) and transmission electron microscopy (TEM). Early stage self-organization of gas bubbles is observed at a fluence of 2.5 × 10 16 ions/cm 2 at temperatures of 300–400 °C. The bubble lattice constant increases with increasing implantation temperature from 300 to 400 °C. Both experiments and atomic kinetic Monte Carlo modeling indicate that the Kr solid bubbles are weakly ordered in comparison to previously studied helium (He) gas bubble superlattice (GBS) while the lattice constant are relatively smaller for Kr SBS compared to that of He GBS. The irradiation conditions suggest that spinodal decomposition, which is a form of phase separation, probably precedes gas bubble ordering in Mo. Altogether, our work sheds light on the formation mechanism of noble gas superlattice toward the development of radiation-tolerant materials which are important for the design of advanced nuclear reactors.

36 MATERIALS SCIENCE↗

Nanostructure-specific X-ray tomography reveals myelin levels, integrity and axon orientations in mouse and human nervous tissue

Myelin insulates neuronal axons and enables fast signal transmission, constituting a key component of brain development, aging and disease. Yet, myelin-specific imaging of macroscopic samples remains a challenge. Here, we exploit myelin’s nanostructural periodicity, and use small-angle X-ray scattering tensor tomography (SAXS-TT) to simultaneously quantify myelin levels, nanostructural integrity and axon orientations in nervous tissue. Proof-of-principle is demonstrated in whole mouse brain, mouse spinal cord and human white and gray matter samples. Outcomes are validated by 2D/3D histology and compared to MRI measurements sensitive to myelin and axon orientations. Specificity to nanostructure is exemplified by concomitantly imaging different myelin types with distinct periodicities. Finally, we illustrate the method’s sensitivity towards myelin-related diseases by quantifying myelin alterations in dysmyelinated mouse brain. This non-destructive, stain-free molecular imaging approach enables quantitative studies of myelination within and across samples during development, aging, disease and treatment, and is applicable to other ordered biomolecules or nanostructures.

36 MATERIALS SCIENCE↗

Shear-free mixing to achieve accurate temporospatial nanoscale kinetics through scanning-SAXS: ion-induced phase transition of dispersed cellulose nanocrystals

Time-resolved in situ characterization of well-defined mixing processes using small-angle X-ray scattering (SAXS) is usually challenging, especially if the process involves changes of material viscoelasticity. In specific, it can be difficult to create a continuous mixing experiment without shearing the material of interest; a desirable situation since shear flow both affects nanoscale structures and flow stability as well as resulting in unreliable time-resolved data. Here, we demonstrate a flow-focusing mixing device for in situ nanostructural characterization using scanning-SAXS. Given the interfacial tension and viscosity ratio between core and sheath fluids, the core material confined by sheath flows is completely detached from the walls and forms a zero-shear plug flow at the channel center, allowing for a trivial conversion of spatial coordinates to mixing times. With this technique, the time-resolved gel formation of dispersed cellulose nanocrystals (CNCs) was studied by mixing with a sodium chloride solution. It is observed how locally ordered regions, so called tactoids, are disrupted when the added monovalent ions affect the electrostatic interactions, which in turn leads to a loss of CNC alignment through enhanced rotary diffusion. The demonstrated flow-focusing scanning-SAXS technique can be used to unveil important kinetics during structural formation of nanocellulosic materials. However, the same technique is also applicable in many soft matter systems to provide new insights into the nanoscale dynamics during mixing.

36 MATERIALS SCIENCE↗

Cross-Sections of Nanocellulose from Wood Analyzed by Quantized Polydispersity of Elementary Microfibrils

Bio-based nanocellulose has been shown to possess impressive mechanical properties and simplicity for chemical modifications. The chemical properties are largely influenced by the surface area and functionality of the nanoscale materials. However, finding the typical cross-sections of nanocellulose, such as cellulose nanofibers (CNFs), has been a long-standing puzzle, where subtle changes in extraction methods seem to yield different shapes and dimensions. Here, we extracted CNFs from wood with two different oxidation methods and variations in degree of oxidation and high-pressure homogenization. Additionally, the cross-sections of CNFs were characterized by small-angle X-ray scattering and wide-angle X-ray diffraction in dispersed and freeze-dried states, respectively, where the results were analyzed by assuming that the cross-sectional distribution was quantized with an 18-chain elementary microfibril, the building block of the cell wall. We find that the results agree well with a pseudosquare unit having a size of about 2.4 nm regardless of sample, while the aggregate level strongly depends on the extraction conditions. Furthermore, we find that aggregates have a preferred cohesion of phase boundaries parallel to the (110)-plane of the cellulose fibril, leading to a ribbon shape on average.

36 MATERIALS SCIENCE↗

Cellulose nanofibrils and nanocrystals in confined flow: Single-particle dynamics to collective alignment revealed through scanning small-angle x-ray scattering and numerical simulations

Nanostructured materials made through flow-assisted assembly of proteinaceous or polymeric nanosized fibrillar building blocks are promising contenders for a family of high-performance biocompatible materials in a wide variety of applications. Optimization of these processes relies on improving our knowledge of the physical mechanisms from nano- to macroscale and especially understanding the alignment of elongated nanoparticles in flows. Here, we study the full projected orientation distributions of cellulose nanocrystals (CNCs) and nanofibrils (CNFs) in confined flow using scanning microbeam SAXS. For CNCs, we further compare with a simulated system of dilute Brownian ellipsoids, which agrees well at dilute concentrations. However, increasing CNC concentration to a semidilute regime results in locally arranged domains called tactoids, which aid in aligning the CNC at low shear rates, but limit alignment at higher rates. Similarly, shear alignment of CNF at semidilute conditions is also limited owing to probable bundle or flock formation of the highly entangled nanofibrils. Finally, this work provides a quantitative comparison of full projected orientation distributions of elongated nanoparticles in confined flow and provides an important stepping stone towards predicting and controlling processes to create nanostructured materials on an industrial scale.

36 MATERIALS SCIENCE↗

Solution scattering at the Life Science X-ray Scattering (LiX) beamline

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q -range of typically 0.006–3.2 Å −1 . Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.

60 APPLIED LIFE SCIENCES↗