Lower and upper threshold limit for artificial neural network based chilled and condenser water temperatures set-point control in a chilled water system

In this study, an ANN (artificial neural network) based real-time optimized control algorithm for a chilled water cooling system was developed and applied in an actual building to analyze its cooling energy saving effects through in-situ application and actual measurements. For this purpose, the cooling tower’s CndWT (condenser water temperature) and the chiller’s ChWT (chilled water temperature) were set as system control variables. To evaluate algorithm performance, the electric consumption and the COP (coefficient of performance) were compared and analyzed when ChWT and CndWTs were controlled conventionally and controlled based on the ANN. During the analysis, unexpected abnormal data was observed due to insufficient training data and limited consideration of OWBT (outdoor air wet-bulb temperature) when determining the CndWT set-point. Therefore, it is necessary to further build training data from a wider range of conditions and to set the lower limit of CndWT set-point to at least +3.6 °C above OWBT when the OWBT is higher than 23 °C, so that further energy savings can be achieved.

42 ENGINEERING↗

Chilled water temperature set-point reset based on outdoor air temperature and its cooling energy performance in an office building

Here, in this study, the cooling energy performance of two strategies for controlling ChWT (chilled water temperature) are compared: the conventional control strategy of constantly fixing ChWT and the OAT (outdoor air temperature) compensation control strategy that adjusts ChWT according to the changes in OAT. OAT compensation control strategy was modeled and realized based on Appendix G of ASHRAE Standard 90.1. It was confirmed that applying OAT compensation control strategy can significantly reduce chiller energy consumption, which accounts for the largest portion of total cooling energy consumption. It was found that the difference in total cooling energy consumption between applying the conventional control of constantly fixing ChWT to 6 °C and applying the OAT compensation control was approximately 8 % and 3 % during spring (March to May) and summer (June to August), respectively. Additionally, during the fall (September–November) period, about 7 % of total cooling energy consumption could be saved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗