Search NASASearch

Engineering topics

Choi, Michael K.

Publications and source records attributed to Choi, Michael K..

At least 19 records

Using Paraffin PCM for Thermal Management of BOLAS Planetary CubeSats with Ion Thrusters

The Bi-sat Observations of the Lunar Atmosphere above Swirls (BOLAS) is a NASA planetary CubeSat mission concept in low lunar orbit. The BOLAS lower CubeSat is at a 90 km altitude above the lunar surface during spiraling down from the Evolved Expendable Launch Vehicle (EELV) Secondary Payload Adapter (ESPA) to the Moon. Without phase change material (PCM), the worst hot case temperature prediction for the Command and Data Handling (C&DH) exceeds the 61°C maximum operating limit, and those for the Iris solid state power amplifier (SSPA) and transponder exceed the 50°C maximum operating limit. Miniature n-Tricosane PCM packs on the Iris SSPA and transponder, and miniature n-Hexacosane PCM packs on the C&DH are used to store thermal energy in sunlight and release it in the eclipse. With paraffin PCM, all the temperatures are within the maximum operating limits.

Choi, Michael K.

Successful Use of Microporous Polytetrafluoroethylene Flexible Thin Sheets in NASA's OSIRIS-REx Mission

Microporous black polytetrafluoroethylene (PTFE) flexible thin sheets are successfully flown as solar diffusers on NASA's Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer (OSIRIS-REx) spacecraft. They serve as multilayer insulation (MLI) blanket outer covers for the arm of the Touch And Go Sample Acquisition Mechanism (TAGSAM), the sunshade of the OSIRIS-REx Camera Suite (OCAMS) PolyCam imager, and the motor riser of the OCAMS SamCam imager. Additionally, microporous white PTFE flexible thin sheets are successfully flown as a MLI blanket outer cover with a low ratio of absorptance to emittance for the Regolith X-ray Imaging Spectrometer (REXIS). For ground testing, microporous black and white PTFE flexible thin sheets were successfully used as optical targets of the Touch And Go Camera System (TAGCAMS) NavCam imagers in the flight system thermal vacuum test.

OSIRIS-REx

Optical Instrument Thermal Control on the Large Ultraviolet/Optical/Infrared Surveyor

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is a multi-wavelength observatory commissioned by NASA as one of four large mission concept studies for the Astro2020 Decadal Survey. Two concepts are under study which bound a range of cost, risk, and scientific return: an 8-meter diameter unobscured segmented aperture primary mirror and a 15-meter segmented aperture primary mirror. Each concept carries with it an accompanying suite of instruments. The Extreme Coronagraph for Living Planetary Systems (ECLIPS) is a near-ultraviolet (NUV) / optical / near-infrared (NIR) coronagraph; the LUVOIR Ultraviolet Multi-object Spectrograph (LUMOS) provides multi-object imaging spectroscopy in the 100-400 nanometer ultraviolet (UV) range; and the High Definition Imager (HDI) is a wide field-of-view near-UV / optical / near-IR camera that can also perform astrometry. The 15-meter concept also contains an additional instrument, Pollux, which is a high-resolution UV spectro-polarimeter. While the observatory is nominally at a 270 Kelvin operational temperature, the requirements of imaging in both IR and UV require separate detectors operating at different temperature regimes, each with stringent thermal stability requirements. The change in observatory size requires two distinct thermal designs per instrument. In this current work, the thermal architecture is presented for each instrument suite. We describe here the efforts made to achieve the target operational temperatures and stabilities with passive thermal control methods. Additional discussion will focus on how these instrument thermal designs impact the overall system-level architecture of the observatory and indicate the thermal challenges for hardware implementation.

LUVOIR

Optical Instrument Thermal Control on the Large Ultraviolet/Optical/Infrared Surveyor

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is a multi-wavelength observatory commissioned by NASA as one of four large mission concept studies for the Astro2020 Decadal Survey. Two concepts are under study which bound a range of cost, risk, and scientific return: an 8-meter diameter unobscured segmented aperture primary mirror and a 15-meter segmented aperture primary mirror. Each concept carries with it an accompanying suite of instruments. The Extreme Coronagraph for Living Planetary Systems (ECLIPS) is a near-ultraviolet (NUV) / optical / near-infrared (NIR) coronagraph; the LUVOIR Ultraviolet Multi-object Spectrograph (LUMOS) provides multi-object imaging spectroscopy in the 100-400 nanometer ultraviolet (UV) range; and the High Definition Imager (HDI) is a wide field-of-view near-UV / optical / near-IR camera that can also perform astrometry. The 15-meter concept also contains an additional instrument, Pollux, which is a high-resolution UV spectro-polarimeter. While the observatory is nominally at a 270 Kelvin operational temperature, the requirements of imaging in both IR and UV require separate detectors operating at different temperature regimes, each with stringent thermal stability requirements. The change in observatory size requires two distinct thermal designs per instrument. In this current work, the thermal architecture is presented for each instrument suite. We describe here the efforts made to achieve the target operational temperatures and stabilities with passive thermal control methods. Additional discussion will focus on how these instrument thermal designs impact the overall system-level architecture of the observatory and indicate the thermal challenges for hardware implementation.

Decadal Study

Thermal Design and Analysis of Cooling SOFIA HIRMES to 4K Cryogenic Temperature Using Cryocooler

HIgh Resolution Mid-infrarEd Spectrometer (HIRMES) is a facility-class instrument aboard the Stratospheric Observatory for Infrared Astronomy (SOFIA) Aircraft Observatory. A TransMIT PTD 406C pulse tube cryocooler (PTC) is used to cool the optical bench and optical components to 4K. A second PTC is dedicated to cool the 3He/4He sorption cooler. The first stages of the PTCs share the heat load from the intermediate temperature stage. The second stage of the first PTC removes nearly all the heat load from the 4 degrees Kelvin stage. The results of thermal analysis show that the 4 degrees Kelvin stage of the HIRMES thermal subsystem meets all of its requirements using the 100 percent heat load margin approach and conservative modeling assumptions.

Cryostat

Thermal Assessment of Paraffin Phase Change Material Mini-Packs on IceCube 3U CubeSat in Flight

Three paraffin phase change material (PCM) mini-packs were flown on the IceCube instrument in the International Space Station (ISS) orbit. They contained a total of 40.69 g of n-Hexadecane. In flight, from Day of Year (DOY) 250-255 in 2017, the IceCube instrument operation scheme was "Day-On Every Other Orbit." The instrument power-on time was approximately 45.6 minutes longer than the design power-on time. Its power-off time was 47 minutes longer than the design power-off time. Flight temperature telemetry data revealed that latent heat change of the paraffin PCM maintained the instrument temperatures at about 18 degrees Centigrade most of the time. It validated the functionality of the paraffin PCM mini-packs.

Paraffin phase change material; CubeSat; latent he

Thermal Assessment of OSIRIS-REx OVIRS Cryogenic Instrument During Flight System TVAC Test and in Flight

The Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) Visible and Infrared Spectrometer (OVIRS) is a cryogenic instrument. At the Outbound Cruise nominal spacecraft attitude, sunlight impinges on several multilayer insulation blankets on the forward deck. It is reflected or scattered to other components on the deck. This solar illumination adds heat load to the OVIRS, and causes its detector temperature to exceed the 105K maximum operating allowable flight temperature limit by 0.8K. During the flight system thermal vacuum test, the solar simulator beam reflected or scattered from the test fixtures to the OVIRS added non-flight heat load. The detector temperature was 9K warmer than that in flight. At those temperatures, the science data was acceptable, despite its quality was not as high as that of 105K or colder.

"OSIRIS-REx; OVIRS; cryogenic instrument; parasiti

Thermal Assessment of Sunlight Impinging on OSIRIS-REx OCAMS PolyCam, OTES, and IMU-Sunshade MLI Blankets in Flight

The NASA Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) spacecraft was successfully launched into orbit on September 8, 2016. It is traveling to a near-Earth asteroid (101955) Bennu, study it in detail, and bring back a pristine sample to Earth for scientific analyses. At the Outbound Cruise nominal spacecraft attitude, with Sun on +X, sunlight impinges on the OSIRIS-REx camera suite (OCAMS) PolyCam sunshade multilayer insulation (MLI) with microporous black polytetrafluoroethylene (PTFE), a portion of the PolyCam optics support tube (MLI with germanium black Kapton (GBK)), a portion of the OSIRIS-REx Thermal Emission Spectrometer (OTES) sunshade (MLI with GBK), the Inertia Measurement Unit (IMU) sunshade (MLI with GBK), and the OSIRIS-REx Laser Altimeter (OLA) sunshade (MLI with GBK). Sunlight is reflected or scattered by the above MLIs to the other components on the forward (+Z) deck. It illuminates the forward deck. A detailed thermal assessment on the solar impingement has been performed for the Proximity Ops at the asteroid, Touch-and-Go (TAG) sample acquisition, and Return Cruise mission phases.The OSIRIS-REx Outbound Cruise flight temperature telemetry and USM_3_DPC_0_CURRENT flight currenttelemetry data have been analyzed. It is evident that at the nominal Outbound Cruise spacecraft Sun-pointing attitude(i.e., Sun on +X), sunlight impinging on the PolyCam, OTES, IMU-sunshade and OLA-sunshade MLIs is reflected orscattered to the forward deck and components on the forward deck. It illuminates the forward deck. The StowCam imageof Day 265 2016 also provided an evidence. The reflected or scattered sunlight cause warming to the forward deck andcomponents on its +Z side. It may also contribute to degradation of thermal coatings over the mission life. It is a factorthat the OVIRS detector operating temperature exceeds the 105K maximum AFT limit. The OVIRS PrincipalInvestigator indicated that it is not optimum but acceptable for science. With exception of the OVIRS detector, thecorrelated flight system thermal model predictions for the components on the forward deck have adequate margins in theProximity Ops, TAG and Return Cruise phases. The margins are expected to cover the warming caused by the solarimpingement and the contribution to degradation of thermal coatings. The solar impingement is not expected to be athermal risk to the OSIRIS-REx mission. The second SRC Optical Properties characterization will be repeated in theReturn Cruise to provide a good characterization of any changes in optical properties that might have occurred duringthe TAG, or during several years in space. If the SRC battery runs much warmer than that of the first characterization inthe Outbound Cruise, it will be necessary to make some changes to the SRC Release timeline to assure the SRC batterytemperature are within limits. If GBK, instead of microporous black PTFE, were used on the PolyCam sunshade MLI,much more sunlight would have been reflected or scattered to the forward deck and components on its +Z side.Microporous black PTFE should be considered to mitigate the optical and thermal issues of sunlight reflected/scatteredby MLI blankets in future missions.

Choi, Michael K.

AZ-2000-IECW and StaMet Black Kapton Options for Solar Probe Plus MAG Sensor MLI Kevlar/Polyimide Shells

AZ-2000-IECW white paint and StaMet black Kapton have been evaluated for the Kevlar/polyimide shells that enclose the Solar Probe Plus Magnetometer (MAG) sensors and multilayer insulation. Flight qualification testing on AZ-2000-IECW painted Kevlar/polyimide laminate was completed at Goddard Space Flight Center. This paint potentially meets all the requirements. However, it has no flight heritage. StaMet is hotter in the sun, and is specular. The results of the MAG thermal balance test show StaMet meets the thermal requirement and heater power budget. The mission prefers to fly StaMet after evaluating the risks of AZ-2000-IECW flaking and glint from StaMet to the Star Trackers.

AZ-2000-IECW; StaMet Black Kapton; Kevlar/Polyimid

Using Paraffin PCM, Cryogel and TEC to Maintain Comet Surface Sample Cold from Earth Approach Through Retrieval

An innovative thermal design concept to maintain comet surface samples cold (for example, 263 degrees Kelvin, 243 degrees Kelvin or 223 degrees Kelvin) from Earth approach through retrieval is presented. It uses paraffin phase change material (PCM), Cryogel insulation and thermoelectric cooler (TEC), which are commercially available.

comet surface sample return; thermoelectric cooler

Using Microporous Polytetrafluoroethylene Thin Sheets as a Flexible Solar Diffuser to Minimize Sunlight Glint to Cameras in Space

An innovative design of using microporous PTFE thin sheets as a solar diffuser for MLI blankets or mechanical structure has been developed. It minimizes sunlight or stray-light glint to cameras when it is incident on these components in space. A microporous black PTFE thin sheet solar diffuser has been qualified for flight at NASA GSFC and installed to the TAGSAM arm MLI, OCAMS PolyCam sunshade MLI and SamCam motor riser MLI in the NASA OSIRIS-REx mission to meet the SamCam camera BRDF requirement.

solar diffuser; flexible solar diffuser

Using Paraffin PCM to Make Optical Communication Type of Payloads Thermally Self-Sufficient for Operation in Orion Crew Module

An innovative concept of using paraffin phase change material with a melting point of 28 C to make Optical Communication type of payload thermally self-sufficient for operation in the Orion Crew Module is presented. It stores the waste heat of the payload and permits it to operate for about one hour by maintaining its temperature within the maximum operating limit. It overcomes the problem of relying on the availability of cold plate heat sink in the Orion Crew Module.

loop heat pipe; heater controller

Swift BAT Thermal Recovery After Loop Heat Pipe #0 Secondary Heater Controller Failure in October 2015

The Swift BAT LHP #0 primary heater controller failed on March 31, 2010. It has been disabled. On October 31, 2015, the secondary heater controller of this LHP failed. On November 1, 2015, the LHP #0 CC temperature increased to as 18.6 C, despite that the secondary heater controller set point was 8.8 C. It caused the average DM XA1 temperature to increase to 25.9 C, which was 5 C warmer than nominal. As a result, the detectors became noisy. To solve this problem, the LHP #1 secondary heater controller set point was decreased in 0.5 C decrements to 2.2 C. The set-point decrease restored the average DM XA1 temperature to a nominal value of 19.7 C on November 21.

thermal recovery in orbit

Paraffin Phase Change Material for Maintaining Temperature Stability of IceCube Type of CubeSats in LEO

The MLA and IFA of the instrument on the IceCube require a 20 C temperature and a thermal stability of +/-1 C. The thermal environment of the ISS orbit for the IceCube is very unstable due to solar beta angles in the -75deg to +75deg range. Additionally the instrument is powered off in every eclipse to conserve electrical power. These two factors cause thermal instability to the MLA and IFA. This paper presents a thermal design of using mini paraffin PCM packs to meet the thermal requirements of these instrument components. With a 31 g mass plus a 30% margin of n-hexadecane, the MLA and IFA are powered on for 32.3 minutes in sunlight at a 0deg beta angle to melt the paraffin. The powered-on time increases to 38 minutes at a 75deg (+/-) beta angle. When the MLA and IFA are powered off, the paraffin freezes.

CubeState

Solar Probe Plus MAG Sensor Thermal Design for Low Heater Power and Extreme Thermal Environment

The heater power available for the Solar Probe Plus FIELDS MAG sensor is less than half of the heritage value for other missions. Nominally the MAG sensors are in the spacecraft's umbra. In the worst hot case, approximately 200 spacecraft communication downlinks, up to 10 hours each, are required at 0.7 AU. These downlinks require the spacecraft to slew 45 deg. about the Y-axis, exposing the MAG sensors and boom to sunlight. This paper presents the thermal design to meet the MAG sensor thermal requirements in the extreme thermal environment and with low heater power. A thermal balance test on the MAG sensor engineering model has verified the thermal design and correlated the thermal model for flight temperature predictions.

Thermal design

Geostationary Coastal and Air Pollution Events (GeoCAPE) Wide Angle Spectrometer (WAS)

The GeoCAPE Wide Angle Spectrometer (WAS) Study was a revisit of the COEDI Study from 2012. The customer primary goals were to keep mass, volume and cost to a minimum while meeting the science objectives and maximizing flight opportunities by fitting on the largest number of GEO accommodations possible. Riding on a commercial GEO satellite minimizes total mission costs. For this study, it is desired to increase the coverage rate,km2min, while maintaining ground sample size, 375m, and spectral resolution, 0.4-0.5nm native resolution. To be able to do this, the IFOV was significantly increased, hence the wide angle moniker. The field of view for COEDI was +0.6 degrees or (2048) 375m ground pixels. The WAS Threshold (the IDL study baseline design) is +2.4 degrees IDL study baseline design) is +2.4 degrees.

pointing and jitter

Method of Minimizing Size of Heat Rejection Systems for Thermoelectric Coolers to Cool Detectors in Space

A thermal design concept of attaching the thermoelectric cooler (TEC) hot side directly to the radiator and maximizing the number of TECs to cool multiple detectors in space is presented. It minimizes the temperature drop between the TECs and radiator. An ethane constant conductance heat pipe transfers heat from the detectors to a TEC cold plate which the cold side of the TECs is attached to. This thermal design concept minimizes the size of TEC heat rejection systems. Hence it reduces the problem of accommodating the radiator within a required envelope. It also reduces the mass of the TEC heat rejection system. Thermal testing of a demonstration unit in vacuum verified the thermal performance of the thermal design concept.

thermoelectric coolers