Search NASA⌕ Search

Engineering topics

Chorpening, Benjamin T.

Publications and source records attributed to Chorpening, Benjamin T..

Design and Implementation of Distributed Ultra-High Temperature Sensing System With a Single Crystal Fiber

Modern high-temperature processes, such as fossil energy production, nuclear reactors, and chemical reactors lack robust, distributed sensing systems to map temperatures in these high-value harsh-environment systems. Regular silica-fiber-based distributed temperature sensing systems usually only operate at temperatures below about 800 °C. In this paper, we present the design, implementation, and testing of a distributed ultra-high temperature sensing system using Raman scattering intensity, which operates from room temperature to above 1400 °C. Consideration is given to the impacts of thermal radiation, fluorescence, and the multimode nature of unclad single-crystal fiber to optimize the system. Results from picosecond and sub-nanosecond lasers were compared. Measurements were taken with a ~2 m sapphire optical fiber, which represents the longest commercially available length. Here, a spatial resolution of 12.4 cm and position standard deviation of 0.28 mm were achieved up to the maximum testing temperature of 1400 °C, which is a new record for distributed temperature sensing systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Abstract - Cooperative Research and Development Agreement between Oxergy, Inc. and National Energy Technology Laboratory

The Raman Gas Analyzer (RGA) has been demonstrated to have an extremely fast response (<1 second), pressurized, multi-gas analysis capability. All but the noble gases are Raman active, although the Raman interaction is weak. The RGA uses a reflectively lined capillary as the optical cell, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations.

47 OTHER INSTRUMENTATION↗

Abstract for CRADA between Solar Turbines Incorporated and NETL

The National Energy Technology Laboratory is developing the Raman Gas Analyzer (RGA) to be a fast, non-destructive instrument for on-line measurement of gas composition. The RGA has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, but Raman interaction is weak with gas phase substances. The RGA uses a reflectively lined capillary as the optical cell in a patented configuration, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (including CO, CO2, N2, O2, H2O). The RGA provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process, such as improving fuel flexibility and efficiency for power generation systems. NETL has constructed a field prototype of the RGA to test the instrument performance in various applications in fossil energy. The objective of this CRADA is to field test the Raman Gas Analyzer in a commercial or near-commercial gas turbine application, to advance its Technology Readiness Level and support technology transfer to the commercial marketplace.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman scattering in single-crystal sapphire at elevated temperatures

Sapphire is a widely used high-temperature material and this work presents thorough characterization of all the measurable Raman scattering modes in sapphire and their temperature dependencies. Here, Raman scattering in bulk sapphire rods is measured from room temperature to 1081 °C and is illustrated as a method of noncontact temperature measurement. A single-line argon ion laser at 488 nm was used to excite the sapphire rods inside a cylindrical furnace. All the anti-Stokes peaks (or lines) were observable through the entire temperature range of interest, while Stokes peaks were observable until they were obscured by background thermal emission. Temperature measurements were found to be most reliable for A 1g and E g modes using the peaks at ±418, ±379, +578, +645, and, +750 cm -1 (+ and – are designated for Stokes and anti-Stokes peaks respectively). The 418 cm -1 peak was found to be the most intense peak. The temperature dependence of peak position, peak width, and peak area of the ±418 and ±379 peaks is presented. For +578, +645 and +750, the temperature dependence of peak position is presented. The peaks’ spectral positions provide the most precise temperature information within the experimental temperature range. Finally, the resultant temperature calibration curves are given, which indicate that sapphire can be used in high-temperature Raman thermometry with an accuracy of about 1.38°C average standard deviation over the entire >1000°C temperature range.

20 FOSSIL-FUELED POWER PLANTS↗

Theoretical and experimental investigation of evanescent-wave absorption sensors for extreme temperature applications

Recently, significant developments in evanescent wave absorption sensors have been demonstrated for high temperature sensing applications based upon the optical responses of advanced thin film materials. We will demonstrate how such sensors can be utilized in a mode that allows for chemical or temperature sensing starting from basic theoretical considerations. We will also present experimental high temperature sensing results for fabricated sensors. Potential applications of the sensors to be discussed include a range of high temperature systems relevant for fossil energy and combustion monitoring such as industrial combustors or reaction vessels, solid oxide fuel cells, and gas turbines. In these applications, even a small increase in operating efficiency realized via careful observation of in-process parameters and implementation of real-time process controls can result in dramatic savings across the energy industry, illustrating the necessity of pursuing such techniques. It is hoped that sensors of the type described here will allow for unprecedented measurement-access to processes which present challenging high-temperature and chemically reactive environments.

47 OTHER INSTRUMENTATION↗

Time varying voltage combustion control and diagnostics sensor

A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

47 OTHER INSTRUMENTATION↗