Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production

Purpose: The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. Methods: The effective range, deflection angle, dose deposition, energy, and interaction processes of electrons produced from the interaction of x-rays with a GNP were calculated by Monte Carlo simulations. The GEANT4 code was used to simulate and track electrons generated from a 2, 50, and 100 nm diameter GNP when it is irradiated with a 50 kVp, 250 kVp, cobalt-60, and 6 MV photon beam in water. Results: When a GNP was present, depending on the beam energies used, secondary electron production was increased by 10- to 2000-fold compared to an absence of a GNP. Low-energy photon beams were much more efficient at interacting with the GNP by two to three orders of magnitude compared to MV energies and increased the deflection angle. GNPs with larger diameters also contributed more dose. The majority of the energy deposition was outside the GNP, rather than self-absorbed by the nanoparticle. The mean effective range of electron tracks for the beams tested ranged from approximately 3 {mu}m to 1 mm. Conclusions: These simulated results yield important insights concerning the spatial distributions and elevated dose in GNP-enhanced radiotherapy. The authors conclude that the irradiation of GNP at lower photon energies will be more efficient for cell killing. This conclusion is consistent with published studies.

60 APPLIED LIFE SCIENCES↗

Dosimetric variation due to the photon beam energy in the small-animal irradiation: A Monte Carlo study

Purpose: The impact of photon beam energy and tissue heterogeneities on dose distributions and dosimetric characteristics such as point dose, mean dose, and maximum dose was investigated in the context of small-animal irradiation using Monte Carlo simulations based on the EGSnrc code. Methods: Three Monte Carlo mouse phantoms, namely, heterogeneous, homogeneous, and bone homogeneous were generated based on the same mouse computed tomography image set. These phantoms were generated by overriding the tissue type of none of the voxels (heterogeneous), all voxels (homogeneous), and only the bone voxels (bone homogeneous) to that of soft tissue. Phase space files of the 100 and 225 kVp photon beams based on a small-animal irradiator (XRad225Cx, Precision X-Ray Inc., North Branford, CT) were generated using BEAMnrc. A 360 deg. photon arc was simulated and three-dimensional (3D) dose calculations were carried out using the DOSXYZnrc code through DOSCTP in the above three phantoms. For comparison, the 3D dose distributions, dose profiles, mean, maximum, and point doses at different locations such as the isocenter, lung, rib, and spine were determined in the three phantoms. Results: The dose gradient resulting from the 225 kVp arc was found to be steeper than for the 100 kVp arc. The mean dose was found to be 1.29 and 1.14 times higher for the heterogeneous phantom when compared to the mean dose in the homogeneous phantom using the 100 and 225 kVp photon arcs, respectively. The bone doses (rib and spine) in the heterogeneous mouse phantom were about five (100 kVp) and three (225 kVp) times higher when compared to the homogeneous phantom. However, the lung dose did not vary significantly between the heterogeneous, homogeneous, and bone homogeneous phantom for the 225 kVp compared to the 100 kVp photon beams. Conclusions: A significant bone dose enhancement was found when the 100 and 225 kVp photon beams were used in small-animal irradiation. This dosimetric effect, due to the presence of the bone heterogeneity, was more significant than that due to the lung heterogeneity. Hence, for kV photon energies of the range used in small-animal irradiation, the increase of the mean and bone dose due to the photoelectric effect could be a dosimetric concern.

60 APPLIED LIFE SCIENCES↗

Monte Carlo calculation of monitor unit for electron arc therapy

Purpose: Monitor unit (MU) calculations for electron arc therapy were carried out using Monte Carlo simulations and verified by measurements. Variations in the dwell factor (DF), source-to-surface distance (SSD), and treatment arc angle ({alpha}) were studied. Moreover, the possibility of measuring the DF, which requires gantry rotation, using a solid water rectangular, instead of cylindrical, phantom was investigated. Methods: A phase space file based on the 9 MeV electron beam with rectangular cutout (physical size=2.6x21 cm{sup 2}) attached to the block tray holder of a Varian 21 EX linear accelerator (linac) was generated using the EGSnrc-based Monte Carlo code and verified by measurement. The relative output factor (ROF), SSD offset, and DF, needed in the MU calculation, were determined using measurements and Monte Carlo simulations. An ionization chamber, a radiographic film, a solid water rectangular phantom, and a cylindrical phantom made of polystyrene were used in dosimetry measurements. Results: Percentage deviations of ROF, SSD offset, and DF between measured and Monte Carlo results were 1.2%, 0.18%, and 1.5%, respectively. It was found that the DF decreased with an increase in {alpha}, and such a decrease in DF was more significant in the {alpha} range of 0 deg. - 60 deg. than 60 deg. - 120 deg. Moreover, for a fixed {alpha}, the DF increased with an increase in SSD. Comparing the DF determined using the rectangular and cylindrical phantom through measurements and Monte Carlo simulations, it was found that the DF determined by the rectangular phantom agreed well with that by the cylindrical one within {+-}1.2%. It shows that a simple setup of a solid water rectangular phantom was sufficient to replace the cylindrical phantom using our specific cutout to determine the DF associated with the electron arc. Conclusions: By verifying using dosimetry measurements, Monte Carlo simulations proved to be an alternative way to perform MU calculations effectively for electron arc therapy. Since Monte Carlo simulations can generate a precalculated database of ROF, SSD offset, and DF for the MU calculation, with a reduction in human effort and linac beam-on time, it is recommended that Monte Carlo simulations be partially or completely integrated into the commissioning of electron arc therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Solid Water as phantom material for dosimetry of electron backscatter using low-energy electron beams: A Monte Carlo evaluation

This study evaluated the dosimetry of electron backscatter when Solid Water is used to substitute water as phantom in electron radiotherapy. Monte Carlo simulation (EGSnrc-based code) was employed to predict electron energy spectra and depth doses for the 0.5 and 1 cm of Solid Water and water slabs above 3 mm of lead (Pb) layers using electron beams with energies of 4 and 6 MeV. For comparison, Monte Carlo simulations were repeated with Pb layers taken out from the phantoms using the same experimental configuration. Analyses on electron energy spectra for the 4 and 6 MeV electron beams showed that deviations of electron energy distributions between the Solid Water and water phantom were more significant in the high-energy range (i.e., close to the maximal electron energy) than the lower range corresponding to the electron backscatter. These deviations of electron energy spectra varied with depth and were mainly due to the electron fluence or beam attenuation. Dosimetry results from Monte Carlo simulations showed that the Solid Water phantom had lower depth dose compared to water with the same experimental setup. For the 4 MeV electron beams with 0.5 cm of Solid Water, depth doses were 1.8%-3.9% and 2.3%-4.4% lower than those in water, with and without the Pb layer underneath, respectively. Thicker Solid Water of 1 cm resulted in different decreases in depth doses of 1.8%-4.6% (with Pb) and 2.3%-4.4% (without Pb) compared to water. For higher nominal electron beam energy of 6 MeV with 0.5 cm of Solid Water, depth doses decreased 1.7%-2.9% (with Pb) and 1.6%-2.1% (without Pb) compared to water. These decreases in depth doses changed to 1.7%-3.7% (with Pb) and 1.7%-3% (without Pb) when the thickness of Solid Water was increased to 1 cm. The dosimetry data in this study are useful in determining the correction factor when using Solid Water to substitute water for the electron backscatter measurement in electron radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Depth dependence of electron backscatter: An energy spectral and dosimetry study using Monte Carlo simulation

This study investigated the depth dependence of electron backscatter from a layer of lead (Pb) for clinical electron beams. The change in the electron backscatter with variation in the water depth above the Pb was determined. Electron energy spectra and relative depth doses as a function of depth in water over the Pb layer were calculated using a Monte Carlo simulation and studied. Phase-space files for 4 and 9 MeV electron beams (10x10 cm{sup 2} applicator and cutout) based on the Varian 21 EX linear accelerator were generated using the EGSnrc-based BEAMNRC code. 3 mm of Pb, at depths of 0.5 and 1 cm in water, was irradiated with electrons. The source-to-surface distance is equal to 100 cm. Electron energy spectra and relative depth doses with and without the presence of the Pb layer at different depths in water were determined using the BEAMNRC code. For the 4 MeV electron energy spectra at a depth of 0.5 cm in water, electron backscatter was found to originate at the Pb-water interface and extend to 0.5 cm above the Pb insert. However, at a depth of 1 cm in water, electron backscatter almost disappeared at 0.5 and 1 cm above th ePb insert. This is due to the increased attenuation of the incident 4 MeV electron beam in a thicker layer of water as well as increased attenuation of the electron backscatter above the Pb. This resulted in a 23% decrease in relative dose at a measurement point of 0.5 cm depth, when the depth of the Pb insert was changed from 1 to 0.5 cm. For the electron energy spectra of the 9 MeV beams with a 0.5 cm depth of water, only a small amount of electron backscatter was observed. However, more electron backscatter was found when the water depth was increased to 1 cm. This is because the electron beam energy was decreased more due to the increase in attenuation from the increased depth of water compared to 0.5 cm. Since the electron energy spectrum and relative depth dose above the Pb layer vary with depth of water on top of the Pb, the electron backscatter depends significantly on the thickness of water, or water equivalent bolus, or critical tissue over the Pb shield in electron radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc

In electron radiotherapy of superficial lesions in the eyelid, lip, buccal mucosa, ear, and nose, backscattered electrons are produced from the lead shield used to protect the critical tissue underneath the tumor. In this study, the backscattered electrons, produced by clinical electron beams using a Varian 21 EX linear accelerator, were studied using Monte Carlo simulations. The electron backscatter factor (EBF), defined as the ratio of dose at the tissue-lead interface to the dose at the same point without the presence of backscatter, was calculated using the Monte Carlo EGSnrc-based code. The calculated EBFs were verified with measurements using metal-oxide-semiconductor field effect transistor detectors. The effect of the (1) initial electron beam energy, (2) thickness of bolus over the lead shield, (3) beam's angle of incidence, and (4) presence of an aluminum sheet used to absorb backscattered electrons, on the EBF, were studied. It is found that for lead shielding positioned at any fixed depth, the EBF decreases with an increase in initial electron beam energy (4-16 MeV). In addition, for depths within the electron practical range, R{sub p}, and at a particular beam energy, the EBF increases with depth (or thickness of the treatment volume). When the electron beam angle increases from 0 deg. to 5 deg., the EBF only decreases slightly (<4%) for all energies. The influence of the beam obliquity on the EBF is important when the treatment surface is not flat and perpendicular to the central beam axis. The use of an aluminum sheet to reduce backscattered electrons was also investigated. For a relatively low electron beam energy (4 MeV), a 2 mm aluminum sheet can reduce backscattering by 31%. While the electron beam energy increased, less backscattered electrons were produced and therefore removed by the same thickness of aluminum (only about 6% for 16 MeV). The Monte Carlo calculated EBFs from this study, characterized by the electron beam energy, depth of bolus above the lead shield, beam obliquity, and presence of an aluminum sheet, may provide important clinical information for radiation oncology staff when considering the effect of electron backscatter on radiotherapy using internal shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: Dose-volume histogram analysis in radiotherapy using the Gaussian error function

A mathematical model based on the Gaussian error and complementary error functions was proposed to describe the cumulative dose-volume histogram (cDVH) for a region of interest in a radiotherapy plan. Parameters in the model (a, b, c) are related to different characteristics of the shape of a cDVH curve such as the maximum relative volume, slope and position of a curve drop off, respectively. A prostate phantom model containing a prostate, the seminal vesicle, bladder and rectum with cylindrical organ geometries was used to demonstrate the effect of interfraction prostate motion on the cDVH based on this error function model. The prostate phantom model was planned using a five-beam intensity modulated radiotherapy (IMRT), and a four-field box (4FB), technique with the clinical target volume (CTV) shifted in different directions from the center. In the case of the CTV moving out of the planning target volume (PTV), that is, the margin between the CTV and PTV is underestimated, parameter c (related to position of curve drop off) in the 4FB plan and parameters b (related to the slope of curve) and c in the IMRT plan vary significantly with CTV displacement. This shows that variation of the cDVH is present in the 4FB plan and such variation is more serious in the IMRT plan. These variations of cDVHs for 4FB and IMRT are due to the different dose gradients at the CTV edges in the anterior and posterior directions for the 4FB and IMRT plan. It is believed that a mathematical representation of the dose-volume relationship provides another viewpoint from which to illustrate problems with radiotherapy delivery such as internal organ motion that affect the dose distribution in a treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗