Search NASA⌕ Search

Engineering topics

Chow, Louis C.

Publications and source records attributed to Chow, Louis C..

Utilization of waste heat from a commercial GT for freshwater production, cooling and additional power: Exergoeconomic analysis and optimization

In this work, a multigeneration system is proposed for power, cooling and freshwater production. The waste heat from a SIEMENS SGT6-2000E GT is utilized to drive a supercritical CO 2 recompression Brayton cycle (SCRBC) and multi-effect desalination (MED) with thermal vapor compressor (TVC), while the waste heat from the pre-cooler of the SCRBC is utilized to drive an absorption cooling cycle. Detailed thermodynamic, exergy and exergoeconomic analyses are performed for the proposed multigeneration system using Engineering Equation Solver (EES). A sensitivity study is also performed to study the effects of the main operational parameters on the proposed system performance. Finally, multi-objective optimization using a genetic algorithm approach in EES is carried out to reach the optimal design. The proposed system can consume 34.2% less energy input and reduce CO 2 emission by 39.3% compared to the stand-alone systems for power, cooling and freshwater production. The results show that the energy utilization factor and exergy efficiency of the proposed system are improved by 33.6% and 14.3%, respectively, while the total unit product cost is reduced by 11.3% compared to the stand-alone GT cycle. Further, from exergoeconomic optimization, the proposed system can produce 132.4 MW of power, 7.09 MW of cooling and 650 kg/s of freshwater at energy utilization factor of 57.5%, exergy efficiency of 39.7% and total unit product cost of 16.3 $/GJ.

42 ENGINEERING↗

High salinity seawater boiling point elevation: Experimental verification

Boiling point elevation (BPE) for high salinity solutions is a crucial parameter that significantly affects the overall thermal efficiency of desalination, water treatment, and many other industrial processing systems, especially when minimum or zero liquid discharge is a key requirement. This paper addresses the discrepancies among the empirical correlations reported in the literature that were commonly used to determine BPE for seawater solutions. An evaluation of the experimental data with low solution concentration reveals that the data cannot be extrapolated to determine the BPE at high concentration (X > 140 ppt or g/kg). Besides, disparities are established within different equations used to determine the BPE for high salinity seawater. As a result of the minimal availability of experimental data of BPE for X > 140 ppt and the need to eliminate the discrepancies, an experimental setup was built, which can produce reliable and repeatable BPE data for any solution concentration. Boiling points were obtained experimentally for seawater solutions with a wide range of salinity (X between 20 and 280 ppt) and brine solution temperature (t b between 20 and 80°C). The experimental results of boiling point elevations for seawater are further compared with the experimental data and analytical results reported in the literature. The newly obtained experimental results show that the minimum and maximum BPE values for the brine solutions tested are 0.175°C at t b = 80°C and X = 20 ppt, and 11.6°C at t b = 80°C and X = 280 ppt, respectively. Furthermore, the measured BPE data for seawater concentration over 80 ppt are fitted and presented using an appropriate fitting model. The new correlation can accurately predict the BPE for high salinity seawater brines and thus should be very helpful in the design of high-energy-efficient evaporation systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient and thermo-economic analysis of MED-MVC desalination system

An exergo-economic model is used to assess the performance of a multi-effect desalination plant integrated to a mechanical vapor compressor unit (MED-MVC) with a water production capacity of 1500 $m^3$/day. The results show that the second law efficiency ($\eta_{II}$) 2.8%. The MVC and evaporator units are responsible for about 39 and 52% of the total exergy destruction, respectively. The total water price (TWP) is 1.70 $\$/m^3$ when calculated using a simple conventional economic model and 1.63 $\$/m^3$ when calculated using an exergy-based cost model. Increasing the number of effects from 1 to 6 results in a 39% reduction in the specific power consumption (SPC), a 70% increase in $\eta_{II}$ and a 24% decrease in TWP. A dynamic model is developed to investigate the effect of fluctuations of compressor work ($\dot{W}_c$) and inlet seawater temperature ($T_{sw}$) on the plant behavior and performance. The dynamic model results show that the disturbance in $\dot{W}$ has a significant effect on the plant transient behavior and may cause the plant to cease operation while a disturbance in $T_{sw}$ has only a moderate impact. Increasing $T_{sw}$ above a certain value of the steady-state condition without proper control on the plant response could lead to evaporator dry out. In term of performance, a reduction in $\dot{W}_c$ causes a decrease in the plant production capacity and SPC, while it increases the plant performance ratio (PR). On the other hand, a reduction in the inlet $T_{sw}$ causes a reduction in the plant production capacity and PR and an increase in SPC for the same compressor work. Furthermore, a comparison between a MED-MVC system and a MED integrated to a thermal vapor compressor system (MED-TVC) reveals that the latter system is rather sensitive to the reduction in $T_{sw}$ due to the presence of the condenser unit in the MED-TVC. The response of the MED-MVC system is slower than the MED-TVC which is due to the high thermal capacity of the preheaters for the feed in the MED-MVC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance modeling of MED-MVC systems: Exergy-economic analysis

In this study, exergy analysis of four different feed configurations of a multi-effect desalination with mechanical vapor compressor (MED-MVC) system is initially studied to identify the area of exergy destruction within system components and followed by an exergo-economic study. The feed configurations considered are forward feed (FF), backward feed (BF), parallel feed (PF) and parallel/cross feed (PCF). From the 1st law energy analysis, the PCF and FF configurations require less work to achieve equal distillate production compared to other two configurations. For instance, the specific power consumption (SPC) values are 30.1, 13.7, 23 and 13.9 kWh/m 3 for the BF, FF, PF and PCF configurations, respectively. Changing the feed arrangement from BF to FF and PF to PCF at a constant compression ratio, the total fixed cost for the MED-MVC plant can be reduced by ~30% and 17%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exergy and thermo-economic analysis for MED-TVC desalination systems

An exergo-economic model is used to simulate four different feed configurations of multi-effect desalination with thermal vapor compressor (MED-TVC) system. The feed configurations considered are backward feed (BF), forward feed (FF), parallel feed (PF) and parallel cross feed (PCF). The model results indicate that the PCF configuration has better performance characteristics than the other feed configurations regarding gain output ratio (GOR) and specific heat consumption (SHC), but it has the highest specific cooling seawater flow rate ($sM_{cw}$). On the other hand, the BF configuration has the lowest $sM_{cw}$. The highest exergy destruction (58%) occurs within the TVC unit and this can be reduced by lowering the supplied motive steam pressure. The exergy destructions in the condenser and pumps account for 4 to 6.7% of the total exergy destruction for all feed configurations. The MED-TVC under consideration has a second law efficiency between 3.9 and 4.6%. Lowering the motive steam pressure for the PCF from 2300 to 300 kPa results in a 7.5% reduction in GOR and a 25.4% increase in the second law efficiency. Reducing the exergy destruction in the TVC unit is cost-effective for the entire system even with the increase in capital investment costs. The specific exergy cost flow method is used to estimate the total water price for BF, FF, PF and PCF as 2.12, 2.30, 2.16 and 2.09 $\$/m^3$, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of disturbances on MED-TVC plant characteristics: Dynamic modeling and simulation

This study describes a detailed steady-state analysis and transient operation of a multi-effect desalination plant with a thermal vapor compressor unit (MED-TVC). The model developed is based on solving the basic conservation equations of mass, energy, and salt. It can predict steady-state operation and transient behavior when the plant is subject to abrupt changes in the main input parameters including motive steam flow rate (m ms ), cooling seawater flow rate (m cw ) and cooling seawater temperature (T cw ). These sudden changes simulate the conditions a MED-TVC plant may be exposed to. Both the steady-state and dynamic aspects of the model are validated against published experimental data. Monitoring the variation of four state variables (vapor temperature, brine level, brine and vapor flow rates) in each effect shows that disturbances in the motive steam flow rate and the cooling seawater temperature have a significant effect on the plant performance. On the other hand, the disturbance in the cooling seawater mass flow rate has only a moderate effect. For all applied disturbances, the change in the brine level is the slowest compared to the changes in vapor temperature, and brine and vapor flow rates. Furthermore, the effect of changing seawater salinity shows a slight effect on the total distillate production and the specific heat transfer area.

42 ENGINEERING↗

Effect of input parameters intensity and duration on dynamic performance of MED-TVC plant

Multi-Effect-Desalination (MED) may be exposed to fluctuations (disturbances) in input parameters during operation. Therefore, there is a requirement to analyze the transient behavior of such MED systems. In this work, a dynamic model is developed and used to examine the effect of abrupt and ramp changes in the main operational parameters on the plant behavior and performance. The results show that the disturbance intensity variation has a major role in the desalination plant behavior. For the current MED-TVC configuration, it is recommended to limit the reduction in the seawater cooling flow rate to under 12% of the designed steady-state value to avoid dry out in the evaporators. Here, a reduction in the motive steam flow rate and cooling seawater temperature of more than 20% and 35% of the nominal operating values, respectively, may lead to flooding in the evaporators and a complete plant shutdown. On the other hand, the disturbance period has a minimal effect on plant performance if it avoids the critical values of the disturbance intensity that can cause plant shutdown. Simultaneous combinations of two different disturbances with opposing effects result in a modest effect on the plant operation and they can be used to control and mitigate the flooding/drying effects of the disturbances. For simultaneous combinations of disturbances with similar effect, the plant needs an accurate control system to avoid an operational shutdown.

42 ENGINEERING↗

Transient performance of MED processes with different feed configurations

Four different configurations of Multi-Effect-Desalination (MED): backward feed (BF), forward feed (FF), parallel feed (PF) and parallel/cross feed (PCF) are modeled in steady and dynamic operation to examine the behavior of these configurations under transient operation. Adding thermal vapor compressor (TVC) unit with the last effect of parallel/cross configuration is also studied and compared to the other configurations to show the advantage of this type of integration. The transient operation is achieved by applying ramp changes (disturbances) in the main input parameters that include steam flow rate at the heat source and cooling seawater temperature and flow rate at the heat sink. Steady state results indicate that parallel/cross feed has a relatively better performance characteristic than the other feed configurations regarding Gain Output Ratio (GOR) and specific heat consumption (SHC). Adding TVC unit to the parallel/cross feed achieves the lowest water production cost. Dynamic results show that MED-TVC with parallel/cross feed has the fastest response while backward feed and forward feed have the slower response to the applied disturbances. In the case of heat source disturbance, MED plants operating in the backward feed arrangement may be exposed to shut down due to the significant increase in brine level for the first effect. The MED-TVC process is susceptible to the heat sink disturbances compared to the PCF and other configurations. Also, changes in input parameters lead to the highest reduction in GOR for the MED-TVC process compared to the different configurations, especially for cooling seawater temperature. The highest reduction in brine level occurs in MED-TVC for a disturbance in the cooling seawater flow rate and may lead to MED-TVC evaporator drying condition. Hence, MED-TVC will require a reliable control system to avoid this type of plant operational disturbance.