Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.

Green, Robert O.↗

Hyperion On-Orbit Calibration Validation with AVIRIS in Argentina

This viewgraph presentation reviews the AVIRIS Argentina Campaign. 125 flight lines were collected for EO-1 science validation team and CONAE-funded investigators. The preliminary results from two vicarious calibration experiments conducted in Argentina are shown. AVIRIS has been shown to be well calibrated. Charts of optical depth measurements, calibration target measured surface reflectance, top-of atmosphere radiance, and images of various sites in Argentina are shown

imaging spectroscopy↗

Development of a Compact Imaging Spectrometer Using Liquid Crystal Tunable Filter Technology

Liquid crystal tunable filters are useful in building compact multi-spectral instruments. The system is portable and adaptable for use in a variety of fields of study in the visible and near-infrared regions of the spectrum.We will present data from calibration targets and some applications, results of the spectral calibration of a spectrometer system, and results of environmental (vibration, radiation, shock, and thermal) testing. Data acquisition and system design are also discussed.

spectrometers imaging↗