Search NASA⌕ Search

Engineering topics

Christian, Matthew

Publications and source records attributed to Christian, Matthew.

DFT-guided flux synthesis of a family of layered titanates crystallizing in the lepidocrocite structure type

K 0.72 Fe 0.72 Ti 1.28 O 4 , a layered mixed-metal oxide belonging to the lepidocrocite structure type, was grown out of a molten KCl-KF mixture at 800 °C. The compound crystallizes in orthorhombic space group Cmcm and exhibits two-dimensional layers, composed of mixed Fe/Ti octahedra, separated by K ions that occupy the interlayer layer space and maintain charge balance. The targeted flux synthesis of the Ni, Cu, and Zn analogs was carried out after density functional theory (DFT) calculations predicted their formation to be energetically favorable, yielding K 0.77 Ni 0.38 Ti 1.62 O 4 , K 0.77 Cu 0.38 Ti 1.62 O 4 , and K 0.73 Zn 0.36 Ti 1.64 O 4 . Finally, all four compositions can be prepared via conventional solid-state technique by mixing and heating stoichiometric amounts of KNO 3 , appropriate transition metal oxide precursors, and TiO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Capture in Novel Porous Liquids

Direct air capture (DAC) of CO 2 is one of the negative emission technologies under development to limit the impacts of climate change. The dilute concentration of CO 2 in the atmosphere (~400 ppm) requires new materials for carbon capture with increased CO 2 selectivity that is not met with current materials. Porous liquids (PLs) are an emerging material that consist of a combination of solvents and porous hosts creating a liquid with permanent porosity. PLs have demonstrated excellent CO 2 selectivity, but the features that control how and why PLs selectively capture CO 2 is unknown. To elucidate these mechanisms, density functional theory (DFT) simulations were used to investigate two different PLs. The first is a ZIF-8 porous host in a water/glycol/2-methylimidazole solvent. The second is the CC13 porous organic cage with multiple bulky solvents. DFT simulations identified that in both systems, CO 2 preferentially bound in the pore window rather than in the internal pore space, identifying that the solvent-porous host interface controls the CO 2 selectivity. Additionally, SNL synthesized ZIF-8 based PL compositions. Evaluation of the long-term stability of the PL identified no change in the ZIF-8 crystallinity after multiple agitation cycles, identifying its potential for use in carbon capture systems. Through this project, SNL has developed a fundamental understanding of solvent-host interactions, as well as how and where CO 2 binds in PLs. Through these results, future efforts will focus not on how CO 2 behaves inside the pore, but on the porous host-solvent interface as the driving force for PL stability and CO 2 selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BYU Capstone Next Generation Vacuum Compton Detector

This BYU Capstone Team Gamma final poster summarizes the work of the team towards a next generation vacuum Compton detector (VCD) for the Nevada National Security Site. The NNSS sponsored this team. Amber Guckes was the mentor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inter- and Intrafraction Patient Positioning Uncertainties for Intracranial Radiotherapy: A Study of Four Frameless, Thermoplastic Mask-Based Immobilization Strategies Using Daily Cone-Beam CT

Purpose: To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Methods and Materials: Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Results: Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts ({+-} SD) were 2.3 ({+-} 1.4), 2.2 ({+-} 1.1), 2.7 ({+-} 1.5), and 2.1 ({+-} 1.0) mm whereas intrafraction motion was 1.1 ({+-} 1.2), 1.1 ({+-} 1.1), 0.7 ({+-} 0.9), and 0.7 ({+-} 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. Conclusions: We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗