Search NASASearch

Engineering topics

Christy, D. E.

Publications and source records attributed to Christy, D. E..

Evaluation program for secondary spacecraft cells

A life cycle test of secondary electric batteries for spacecraft applications was conducted. A sample number of nickel cadmium batteries were subjected to general performance tests to determine the limit of their actual capabilities. Weaknesses discovered in cell design are reported and aid in research and development efforts toward improving the reliability of spacecraft batteries. A statistical analysis of the life cycle prediction and cause of failure versus test conditions is provided.

Christy, D. E.

Evaluation program for secondary spacecraft cells: Acceptance tests of Eagle-Picher 20.0 ampere-hour nickel-cadmium cells with auxiliary electrodes

A group of 29 cells with capacities ranging from 21.7 to 28.8 ampere-hours were tested. A summary of the results indicates: (1) All cells exceeded the rated capacity on all three capacity checks. (2) Five cells failed to recover to 1.150 volts. (3) During the overcharge tests, 15 of the 29 cells had to be removed from charge before completion of the respective tests due to high pressure.

Christy, D. E.

Evaluation program for secondary spacecraft cells: Acceptance test of Eagle-Picher 100 ampere-hour nickel-cadmium cells with auxiliary electrodes

Tests were conducted on a group of 29 cells for the purpose of removing from the life cycle program all cells found to have electrolyte leakage, internal shorts, low capacity, or inability to recover open circuit voltage above 1.150 volts after the cell short test. The test findings include the following: (1) All the cells exceeded the rated capacity of 103.5 to 119.0 ampere-hours on all three capacity checks. (2) All cells recovered above the 1.150 volt requirement after the cell short test. (3) The cells cannot be overcharged at the c/10 rate without exceeding 1.500 volts after approximately 12 to 13 hours of charge. (4) The resistance value necessary to provide maximum signal power across the auxiliary electrode was found to be 10 ohms. (5) One cell revealed a definite leak at the negative terminal.

Christy, D. E.

Evaluation program for secondary spacecraft cells

The life cycle test of secondary spacecraft electric cells is discussed. The purpose of the tests is to insure that all cells put into the life cycle test meet the required specifications. The evaluation program gathers statistical information concerning cell performance characteristics and limitations. Weaknesses in cell design which are discovered during the tests are reported to research facilities in order to increase the service life of the cells.

Christy, D. E.

Evaluation program for secondary spacecraft cells: Acceptance tests of Eagle-Picher 12.0 ampere-hour nickel-cadmium cells with auxiliary electrodes

An acceptance test program was conducted on 24 cells to insure that all cells put into the life cycle program were of high quality by the removal of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts after the cell short test. The cells were rated at 12.0 ampere-hours and equipped with auxiliary electrodes. Test results were: (1) The capacity of the 24 cells ranged from 14.6 to 16.8 ah. All the cells exceeded the rated capacity on all three capacity checks. (2) One cell failed to recover to 1.150 volts after the cell short test. (3) During the overcharge tests, all cells but one failed the test at the c/10 rate after the first minute. (4) A special resistance test was conducted on the auxiliary electrodes of these cells to establish the resistance value necessary which would provide maximum signal power across the auxiliary electrode. The resistance value established was 10 ohms. (5) No electrolyte leakage was observed.

Christy, D. E.