The need for application-based adaptation of deformable image registration

Purpose: To utilize a deformable phantom to objectively evaluate the accuracy of 11 different deformable image registration (DIR) algorithms. Methods: The phantom represents an axial plane of the pelvic anatomy. Urethane plastic serves as the bony anatomy and urethane rubber with three levels of Hounsfield units (HU) is used to represent fat and organs, including the prostate. A plastic insert is placed into the phantom to simulate bladder filling. Nonradiopaque markers reside on the phantom surface. Optical camera images of these markers are used to measure the positions and determine the deformation from the bladder insert. Eleven different DIR algorithms are applied to the full and empty-bladder computed tomography images of the phantom (fixed and moving volumes, respectively) to calculate the deformation. The algorithms include those from MIM Software (MIM) and Velocity Medical Solutions (VEL) and nine different implementations from the deformable image registration and adaptive radiotherapy toolbox for Matlab. These algorithms warp one image to make it similar to another, but must utilize a method for regularization to avoid physically unrealistic deformation scenarios. The mean absolute difference (MAD) between the HUs at the marker locations on one image and the calculated location on the other serves as a metric to evaluate the balance between image similarity and regularization. To demonstrate the effect of regularization on registration accuracy, an additional beta version of MIM was created with a variable smoothness factor that controls the emphasis of the algorithm on regularization. The distance to agreement between the measured and calculated marker deformations is used to compare the overall spatial accuracy of the DIR algorithms. This overall spatial accuracy is also utilized to evaluate the phantom geometry and the ability of the phantom soft-tissue heterogeneity to represent patient data. To evaluate the ability of the DIR algorithms to accurately transfer anatomical contours, the rectum is delineated on both the fixed and moving images. A Dice similarity coefficient is then calculated between the contour on the fixed image and that transferred, via the calculated deformation, from the moving to the fixed image. Results: The phantom possesses sufficient soft-tissue heterogeneity to act as a proxy for patient data. Large discrepancies appear between the algorithms and the measured ground-truth deformation. VEL yields the smallest mean spatial error and a Dice coefficient of 0.90. MIM produces the lowest MAD value and the highest Dice coefficient of 0.96, but creates the largest spatial errors. Increasing the MIM smoothness factor above the default value improves the overall spatial accuracy, but the factor associated with the lowest mean error decreases the Dice coefficient to 0.85. Conclusions: Different applications of DIR require disparate balances between image similarity and regularization. A DIR algorithm that is optimized only for its ability to transfer anatomical contours will yield large deformation errors in homogeneous regions, which is problematic for dose mapping. For this reason, these algorithms must be tested for their overall spatial accuracy. The developed phantom is an objective tool for this purpose.

60 APPLIED LIFE SCIENCES↗

Stereotactic Body Radiotherapy as Monotherapy or Post-External Beam Radiotherapy Boost for Prostate Cancer: Technique, Early Toxicity, and PSA Response

Purpose: High dose rate (HDR) brachytherapy has been established as an excellent monotherapy or after external-beam radiotherapy (EBRT) boost treatment for prostate cancer (PCa). Recently, dosimetric studies have demonstrated the potential for achieving similar dosimetry with stereotactic body radiotherapy (SBRT) compared with HDR brachytherapy. Here, we report our technique, PSA nadir, and acute and late toxicity with SBRT as monotherapy and post-EBRT boost for PCa using HDR brachytherapy fractionation. Patients and Methods: To date, 38 patients have been treated with SBRT at University of California-San Francisco with a minimum follow-up of 12 months. Twenty of 38 patients were treated with SBRT monotherapy (9.5 Gy Multiplication-Sign 4 fractions), and 18 were treated with SBRT boost (9.5 Gy Multiplication-Sign 2 fractions) post-EBRT and androgen deprivation therapy. PSA nadir to date for 44 HDR brachytherapy boost patients with disease characteristics similar to the SBRT boost cohort was also analyzed as a descriptive comparison. Results: SBRT was well tolerated. With a median follow-up of 18.3 months (range, 12.6-43.5), 42% and 11% of patients had acute Grade 2 gastrourinary and gastrointestinal toxicity, respectively, with no Grade 3 or higher acute toxicity to date. Two patients experienced late Grade 3 GU toxicity. All patients are without evidence of biochemical or clinical progression to date, and favorably low PSA nadirs have been observed with a current median PSA nadir of 0.35 ng/mL (range, <0.01-2.1) for all patients (0.47 ng/mL, range, 0.2-2.1 for the monotherapy cohort; 0.10 ng/mL, range, 0.01-0.5 for the boost cohort). With a median follow-up of 48.6 months (range, 16.4-87.8), the comparable HDR brachytherapy boost cohort has achieved a median PSA nadir of 0.09 ng/mL (range, 0.0-3.3). Conclusions: Early results with SBRT monotherapy and post-EBRT boost for PCa demonstrate acceptable PSA response and minimal toxicity. PSA nadir with SBRT boost appears comparable to those achieved with HDR brachytherapy boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics strategies for sparing neural stem cells during whole-brain radiation treatments

Purpose: Currently, there are no successful long-term treatments or preventive strategies for radiation-induced cognitive impairments, and only a few possibilities have been suggested. One such approach involves reducing the dose to neural stem cell compartments (within and outside of the hippocampus) during whole-brain radiation treatments for brain metastases. This study investigates the fundamental physics issues associated with the sparing of neural stem cells during photon radiotherapy for brain metastases. Methods: Several factors influence the stem cell dose: intracranial scattering, collimator leakage, beam energy, and total number of beams. The relative importance of these factors is investigated through a set of radiation therapy plans, which are all variations of an initial 6 MV intensity-modulated radiation therapy (IMRT) plan designed to simultaneously deliver a whole-brain dose of 30 Gy and maximally reduce stem cell compartment dose. Additionally, an in-house leaf segmentation algorithm was developed that utilizes jaw motion to minimize the collimator leakage. Results: The plans are all normalized such that 50% of the PTV receives 30 Gy. For the initial 6 MV IMRT plan, 50% of the stem cells receive a dose greater than 6.3 Gy. Calculations indicate that 3.6 Gy of this dose originates from intracranial scattering. The jaw-tracking segmentation algorithm, used in conjunction with direct machine parameter optimization, reduces the 50% stem cell dose to 4.3 and 3.7 Gy for 6 and 10 MV treatment beams, respectively. Conclusions: Intracranial scattering alone is responsible for a large dose contribution to the stem cell compartment. It is, therefore, important to minimize other contributing factors, particularly the collimator leakage, to maximally reduce dose to these critical structures. The use of collimator jaw tracking in conjunction with modern collimators can minimize this leakage.

61 RADIATION PROTECTION AND DOSIMETRY↗

A two-dimensional deformable phantom for quantitatively verifying deformation algorithms

Purpose: The incorporation of deformable image registration into the treatment planning process is rapidly advancing. For this reason, the methods used to verify the underlying deformation algorithms must evolve equally fast. This manuscript proposes a two-dimensional deformable phantom, which can objectively verify the accuracy of deformation algorithms, as the next step for improving these techniques. Methods: The phantom represents a single plane of the anatomy for a head and neck patient. Inflation of a balloon catheter inside the phantom simulates tumor growth. CT and camera images of the phantom are acquired before and after its deformation. Nonradiopaque markers reside on the surface of the deformable anatomy and are visible through an acrylic plate, which enables an optical camera to measure their positions; thus, establishing the ground-truth deformation. This measured deformation is directly compared to the predictions of deformation algorithms, using several similarity metrics. The ratio of the number of points with more than a 3 mm deformation error over the number that are deformed by more than 3 mm is used for an error metric to evaluate algorithm accuracy. Results: An optical method of characterizing deformation has been successfully demonstrated. For the tests of this method, the balloon catheter deforms 32 out of the 54 surface markers by more than 3 mm. Different deformation errors result from the different similarity metrics. The most accurate deformation predictions had an error of 75%. Conclusions: The results presented here demonstrate the utility of the phantom for objectively verifying deformation algorithms and determining which is the most accurate. They also indicate that the phantom would benefit from more electron density heterogeneity. The reduction of the deformable anatomy to a two-dimensional system allows for the use of nonradiopaque markers, which do not influence deformation algorithms. This is the fundamental advantage of this verification technique.

61 RADIATION PROTECTION AND DOSIMETRY↗