Search NASA⌕ Search

Engineering topics

Chun Y Tang

Publications and source records attributed to Chun Y Tang.

Mars Entry Instrumentation Flight Data and Mars 2020 Entry Environments

On February 18th, 2021, the Mars 2020 entry vehicle delivered the Perseverance rover to the surface of Mars. The entry vehicle carried a set of instrumentation installed on the heatshield and backshell to measure aerodynamic and aerothermal performance, named the Mars Entry, Descent, and Landing Instrumentation 2. This set of instrumentation included pressure transducers, thermocouples, heatflux sensors, and a radiometer, as well as a dedicated sensor support electronics system. All MEDLI2 hardware operated as expected during cruise and entry. MEDLI2 sensors gathered accurate pressure measurements in hypersonic through supersonic regimes to reconstruct vehicle attitude and atmospheric profiles. MEDLI2 on the heatshield sensors indicated that surface temperatures, caused by turbulent heating beginning 70 seconds after entry, remained at or below 1430 °C, while heatshield bondline temperatures rose less than 45 °C. Backshell surface TPS temperatures peaked at 630 °C, which was caused primarily by radiative heating measured by several separate sensors. The MEDLI2 temperature and pressure measurements enabled further detailed characterization of the Mars 2020 entry performance, and the flight dataset will provide a wealth of information for the EDL community and future mission designers.

thermal protection system↗

Computational Investigation of Powered Descent for Human-Scale Mars Landers

NASA human-scale Mars entry, descent, and landing vehicles currently under consideration have system requirements beyond the current state of the art. Specifically, heritage approaches for deceleration using parachutes and initiating engines at subsonic speeds are not adequate to land these large vehicles (50-60 metric ton entry mass) precisely (within 50 meters of a surface target). Therefore, the present approach for landing humans on Mars utilizes entry vehicles with large aerodynamic surface areas that transition to the descent and landing phase by initiating retropropulsion at supersonic speeds. Vehicle performance, including stability and control, depends on accurate characterization of the aerodynamic-propulsive interference effects, especially at engine initiation, when the vehicles are transitioning from an entry attitude to that suitable for descent and landing. This paper summarizes the human Mars entry vehicle configurations, retropropulsion integration, performance assumptions, and expected flight environment at engine initiation. Cases spanning supersonic, transonic, and subsonic conditions during powered descent are analyzed using four computational fluid dynamics codes, all of which have been previously applied to supersonic retropropulsion at varying scales and conditions. The results of the analysis are used to develop an aerodynamic-propulsive interference model that has since been applied in trajectory simulations to augment the fidelity of human-scale Mars entry vehicle performance.

Ashley M Korzun↗

Characterization of Radiative Heating Anomaly in High Enthalpy Shock Tunnels

Surface heating measurements in shock tunnels operating at high enthalpy have previously showed anomalously high heating, the mechanisms for which have been the subject of much speculation. However, recent tests in JAXA’s High Enthalpy Shock Tunnel (HIEST) have presented compelling evidence that the heating anomaly is due to radiation from the shock layer, produced by impurities within the shock. This paper describes a test series performed with an Apollo capsule model at angle of attack. The purpose of the test is nominally to study transition over the capsule model at high enthalpy, however data is confounded by the presence of this radiative heating. The model is thus instrumented with thermocouple heat flux gauges and spectrometer-coupled fiber optics to characterize the spectrum of radiative heating simultaneous to the heat flux measurements. Analyses of the spectra, estimates of radiative heating corrections, and comparison to computational fluid dynamic simulation of the shock tunnel are presented.

Brett A Cruden↗

MEDLI2: MISP Measured Aftbody Aerothermal Environments

The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite on the Mars 2020 mission included two total heat flux sensors and one radiometer on the backshell to directly measure the aftbody aerothermal environments during entry into the Martian atmosphere. All three sensors successfully returned aftbody entry heating measurements. Comparisons between the total heat flux sensor measurements and DPLR/NEQAIR predictions show excellent agreement and provide confidence in the models. The radiometer measured significant radiative heating but compared to the model predictions the signal was attenuated by 50% at the end of the entry heat pulse. The loss of signal is attributed to blockage by thermal protection system (TPS) ablation product deposits on the radiometer window. Ground-based testing in the NASA Ames arc jet facilities was conducted to understand the impact of ablation product deposits on the measured radiometer signal. A discussion of the test results, how flight-like the test conditions were, and future work to further characterize the effect of TPS ablation product deposits on the radiometer performance are presented. In addition to measuring the entry heat pulse all three sensors were sensitive enough to measure solar radiation during cruise, the radiometer measured solar flux during the entry heat pulse, and the leeside total heat flux sensor picked up the descent reaction control system firings.

Ruth A Miller↗

MEDLI2: MISP Inferred Aerothermal Environment and Flow Transition Assessment

The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite on the Mars2020 mission contained multiple sensors on the aeroshell to measure the aerothermal environment during entry into the Martian atmosphere. These sensors performed superbly and successfully returned forebody and aftbody heating measurements. Analysis of MEDLI2 data indicated flow transitioning from a laminar to turbulent state on the heatshield. No evidence of flow transition was observed on the backshell. Two methods were used to estimate flow transition times on the heatshield: (1) temperature gradient of near-surface thermocouple data and (2) heat flux gradient from an inverse reconstruction approach using thermocouple data and material response modeling. Both methods produced similar transition times with an estimated accuracy of ±1 s. To assess various transition criteria, transition parameters were evaluated at each sensor location using flow field solutions from computational fluid dynamics (CFD) simulations. The idea was to use conservative values inferred from MEDLI2 data as transition criteria for other Mars missions. To test this hypothesis, MEDLI data from the Mars Science Laboratory (MSL) mission was used to compare predicted vs. actual flow transition times. The comparisons suggest smooth wall transition criteria are not well-suited in modeling the rapid progression of a turbulent transition front. Transition criteria containing a roughness element parameter agreed better with the flight data. In summary, critical transition values derived from MEDLI2 data may be used as a starting point in constructing a flow transition model for future Mars missions.

Chun Y Tang↗