Search NASA⌕ Search

Engineering topics

Chupp, T.

Publications and source records attributed to Chupp, T..

Abrasion-fission reactions at intermediate energies

The availability of high-intensity, heavy-ion beams coupled to sensitive, large solid-angle acceptance spectrometers has enabled a detailed examination of the fission fragments produced in induced-fission reactions. The abrasion fission process involves the formation of projectile-like prefragments in violent nuclear collisions at relative energies in excess of 100 MeV/u. At intermediate energies below this threshold, experiments suggest a change in the prefragment kinematic qualities. Information regarding the influence of this transitional phase upon the evolution of nuclei approaching the point of scission is scarce. In this article, data are presented for over 200 nuclei from nickel to palladium produced in abrasion-fission reactions of a 80 MeV/u 238 U beam. Cross sections were obtained following yield measurements performed for the principal charge states of the identified fission fragments and a detailed analysis of the ion transmission. A full kinematic analysis of the fission fragments has been performed using the LISE ++ software package, where the trajectory of an ion passing through a spectrometer can be reconstructed based upon measurements at the focal plane. Furthermore, the results obtained at the S800 spectrograph are compared with predictions obtained with a three-fission progenitor (3EER) model. Systematic studies of fission-fragment properties continue to provide a valuable experimental benchmark for theoretical efforts directed toward describing this complex decay channel, that is important in the context of planning experiments to explore the neutron-rich region of the nuclear chart at rare-isotope beam facilities.

59 ≤ A ≤ 8990 ≤ A ≤ 149↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron decay correlations in the Nab experiment

The Nab experiment will measure the correlation a between the momenta of the beta particle and antineutrino in neutron decay as well as the Fierz term b which distorts the beta spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A large-scale magnetic shield with 10{sup 6} damping at millihertz frequencies

We present a magnetically shielded environment with a damping factor larger than 1 × 10{sup 6} at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an improvement of the state-of-the-art in the difficult regime of damping very low-frequency distortions by more than an order of magnitude. This technology enables a new generation of high-precision measurements in fundamental physics and metrology, including searches for new physics far beyond the reach of accelerator-based experiments. We discuss the technical realization of the shield with its improvements in design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isotopes and Applications Working Group: Report update October 2013

No significant changes are proposed for the scientific program. The standard mode of operation at FRIB will be to produce a rare isotope beam for a primary user, for example 60 Ca from a 82 Se beam. At the same time, the fragmentation or fission of the production beam will produce up to 1000 other isotopes that could be collected (harvested) and used for other experiments or applications. The potential applications of these harvested isotopes range from the determination of neutron cross sections for homeland security to kinetic studies of radionuclide uptake in biological processes. Longer-lived samples of the unused isotopes could be collected and used in an ion source for accelerated beam experiments at ReA3, ReA12 or other accelerator facilities outside FRIB.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Neutron Beta Decay Studies with Nab

Precision measurements in neutron beta decay serve to determine the coupling constants of beta decay and allow for several stringent tests of the standard model. This paper discusses the design and the expected performance of the Nab spectrometer.

neutron beta decay↗