Search NASA⌕ Search

Engineering topics

Cichon, Aleksandra

Publications and source records attributed to Cichon, Aleksandra.

Water desalination through the dewpoint evaporative system

This paper presents the first numerical analysis of a novel Dew Point Desalination unit (DPD), which utilizes the phenomenon of the evaporative cooling process to minimize energy consumption. The proposed solution is based on a modular structure, which allows it to obtain any required water production capacity. The analyses for various operational parameters and various climatic conditions are based on the numerical simulations conducted using a validated mathematical model. The system performance was described with different factors, including specific energy consumption (SEC) and daily water production rate respected to 1 m^3*s^-1 of passing air stream (DWP). It is shown that the DPD system can operate in almost every climate zone, and the desalinated water production consumes less than 1.5 kWh*m^-3 of electric energy It is noted the best performance of the DPD system is achieved in the semi-arid, desert and subtropical climate zones. In these climate zones, the 2-stage DPD system allows the production of desalinated water with an electric energy consumption SEC lower than 0.5 kWh*m^-3. The additional benefit of the DPD system is its modularity. The presented DPD system stands as a module, that can be multiplied as needed to achieve the desired size of the desalination plant.

Desalination↗

Experimental study of plate materials for evaporative air coolers

Following paper presents an experimental study on eight potential plate materials for evaporative air coolers. There are three groups of materials: currently used plate materials (kraft papers), new natural origin plate materials (cotton fibers), and new synthetic plate materials (synthetic fibers). Proposed materials were examined in terms of different properties such as upward and downward distribution height, water capacity, durability and diffusivity. The results were compared with data presented by other authors. It was established that, synthetic materials are characterized by superior water distribution qualities in comparison to the materials of natural origin. Basalt paper-like synthetic fiber allowed to rise water vertically to 40 cm during 120 min tests. The highest water rise obtained in other studies was 18 cm, hence basalt paper-like fiber is visibly superior in comparison with the currently known materials. In terms of downward water distribution, two new synthetic surfactant non-wovens show better performance than the existing materials by quickly and evenly distributing water over the entire length of the sample. The durability of synthetic fibers and non-wovens is higher comparing with the materials of natural origin. The results show that synthetic materials are better suited to the role of plate materials in evaporative air coolers.

Experiment↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗